Skip to content
SafetyRecord logoSafetyRecord
KEWANNA METAL SPECIALTIES INC.
$5,195
penalties
25
viol.
9
insp.

KEWANNA METAL SPECIALTIES INC.

W MAIN ST, Kewanna, IN 46939

Inspections
9
Mar 1983 to Sep 2012 · 9 safety, 0 health
Violations
25
across 9 inspections
Penalties on record
$5,195
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 20, 2012Programmed Related (I) · Complete scope, Safety#316485267$2442 viol.

Inspection #316485267

Dates

Opened
Sep 20, 2012
Closing Conference Date
Sep 20, 2012
Closed
Oct 30, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
57

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$375
Penalties on Record
$244
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
332618 Other Fabricated Wire Product Manufacturing

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 III
Serious15$375$244Oct 22, 2012--
020011910.303
OSHA citation code: 19100303 G01 II
Other12$0$0Oct 22, 2012--
Sep 18, 2007Planned (H) · Complete scope, Safety#311254809$9102 viol.

Inspection #311254809

Dates

Opened
Sep 18, 2007
Closing Conference Date
Sep 19, 2007
Closed
Oct 15, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
56

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,400
Penalties on Record
$910
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious16$700$455Oct 4, 2007--
010021910.303
OSHA citation code: 19100303 G02 I
Serious12$700$455Oct 4, 2007--
May 16, 2007Planned (H) · Records Only scope, Safety#310371323$00 viol.

Inspection #310371323

Dates

Opened
May 16, 2007
Closing Conference Date
May 16, 2007
Closed
May 29, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 11, 1999Planned (H) · Complete scope, Safety#125353458$2853 viol.

Inspection #125353458

Dates

Opened
May 11, 1999
Closing Conference Date
May 11, 1999
Closed
Aug 12, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$375
Penalties on Record
$285
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious14$375$285Jul 12, 1999--
020011910.22
OSHA citation code: 19100022 D01
Other110$0$0Jul 25, 1999--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other15$0$0Jul 12, 1999--
Oct 29, 1997Planned (H) · Partial scope, Safety#123987976$6251 viol.

Inspection #123987976

Dates

Opened
Oct 29, 1997
Closing Conference Date
Oct 29, 1997
Closed
Dec 12, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$625
Penalties on Record
$625
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious11$625$625Dec 9, 1997--
Sep 15, 1992Planned (H) · Complete scope, Safety#114946429$2,8117 viol.

Inspection #114946429

Dates

Opened
Sep 15, 1992
Closing Conference Date
Sep 15, 1992
Closed
Feb 10, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$7,500
Penalties on Record
$2,811
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other14$1,250$0Nov 28, 1992--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other12$1,250$0Dec 8, 1992--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$1,250$937Nov 25, 1992--
010041910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious14$1,250$937Nov 28, 1992--
010051910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious66$1,250$937Nov 25, 1992--

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 17, 1987Follow-Up (F) · Partial scope, Safety#104026646$00 viol.

Inspection #104026646

Dates

Opened
Sep 17, 1987
Closing Conference Date
Sep 17, 1987
Closed
Sep 23, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 16, 1987Planned (H) · Complete scope, Safety#104026489$03 viol.

Inspection #104026489

Dates

Opened
Jul 16, 1987
Closing Conference Date
Jul 16, 1987
Closed
Sep 23, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
419 W. Main Street, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other22$0$0Aug 3, 1987--
010021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other11$0$0Jul 30, 1987--
010031910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Other22$0$0Jul 30, 1987--
Mar 22, 1983Planned (H) · Complete scope, Safety#215184920$3207 viol.

Inspection #215184920

Dates

Opened
Mar 22, 1983
Closing Conference Date
Not recorded
Closed
Mar 22, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
42

Violations and Penalties

Total Violations
7
Violation Types
2 serious, 5 other-than-serious
Initial Penalties
$540
Penalties on Record
$320
Site Address
W Main St, Kewanna, IN 46939
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious3-$240$160May 16, 1983--
010031910.252
General requirements
OSHA citation code: 19100252 C02 IV
Serious11-$300$160Jul 6, 1983--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other2-$0$0May 16, 1983--
020021910.252
General requirements
OSHA citation code: 19100252 A02 IVC
Other1-$0$0Mar 22, 1983--
020031910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Other1-$0$0Mar 23, 1983--

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.304Wiring design and protection4 citations · $937
1910.212General Requirements for All Machines (Machine Guarding)3 citations · $1,097
1910.217Mechanical Power Presses3 citations · $2,017

Industry comparison

BLS 2024 survey: spring and wire product manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.7%; NAICS 33261 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Kewanna, IN

All employers in Kewanna →