Skip to content
SafetyRecord logoSafetyRecord
KIRST CONSTRUCTION INC
$4,965
penalties
21
viol.
3
insp.

KIRST CONSTRUCTION INC

CEDARGROVE APT PROJECT, Cheektowaga, NY 14225

Inspections
3
Oct 1981 to Jun 1997 · 2 safety, 1 health
Violations
21
across 3 inspections
Penalties on record
$4,965
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 1Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 27, 1997Programmed Related (I) · Complete scope, Health#300999273$4,83012 viol.

Inspection #300999273

Dates

Opened
Jun 27, 1997
Closing Conference Date
Sep 30, 1997
Closed
Dec 12, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
12
Violation Types
9 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$6,900
Penalties on Record
$4,830
Site Address
2605 Harlem Road, Cheektowaga, NY 14225
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious11$900$630Nov 3, 1997--
01002A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D08
Serious11$1,200$840Nov 3, 1997--
01002B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D23
Serious11$0$0Nov 3, 1997--
01002C1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 I02
Serious13$0$0Nov 3, 1997--
01002D1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 I03
Serious13$0$0Nov 3, 1997--
01002E1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 I04
Serious13$0$0Nov 3, 1997--
010031926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious14$1,200$840Nov 16, 1997--
01004A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B20
Serious11$1,200$840Nov 3, 1997--
01004B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B21
Serious11$0$0Nov 3, 1997--
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Repeat14$2,400$1,680Nov 3, 1997--
030011926.152
OSHA citation code: 19260152 A01
Other11$0$0Nov 2, 1997--
030021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other11$0$0Nov 3, 1997--
Feb 9, 1982Planned (H) · Complete scope, Safety#10838092$1355 viol.

Inspection #10838092

Dates

Opened
Feb 9, 1982
Closing Conference Date
Feb 18, 1982
Closed
Mar 25, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$270
Penalties on Record
$135
Site Address
Senior Citizen Center, Cheektowaga, NY 14225
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A 011014
Serious2-$180$90Feb 26, 1982--
01001B1926.402
Applicability (Electrical - Construction)
OSHA citation code: 19260402 A08
Serious1-$0$0Feb 26, 1982--
01002A1926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 B01
Serious1-$90$45Feb 26, 1982--
01002B1926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 B01
Serious2-$0$0Feb 26, 1982--
020011926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 H01
Other1-$0$0Mar 5, 1982--
Oct 27, 1981Planned (H) · Complete scope, Safety#10837805$04 viol.

Inspection #10837805

Dates

Opened
Oct 27, 1981
Closing Conference Date
Oct 27, 1981
Closed
Dec 7, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Cedargrove Apt Project, Cheektowaga, NY 14225
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 H01
Other1-$0$0Nov 6, 1981--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D03
Other1-$0$0Nov 6, 1981--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A05
Other1-$0$0Nov 6, 1981--
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 S05
Other1-$0$0Nov 6, 1981--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.502Fall Protection Systems Criteria and Practices5 citations · $840
1926.451Scaffolding - General Requirements3 citations · $0
1926.400Introduction (Electrical - Construction)3 citations · $90

Other inspected employers in Cheektowaga, NY

All employers in Cheektowaga →