Skip to content
SafetyRecord logoSafetyRecord
KOLDKIST BEVERAGE & ICE INC
$1,230
penalties
19
viol.
5
insp.

KOLDKIST BEVERAGE & ICE INC

909 N COLUMBIA BLVD, Portland, OR 97217

Inspections
5
Dec 1991 to Feb 2005 · 4 safety, 1 health
Violations
19
across 5 inspections
Penalties on record
$1,230
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 14, 2005Planned (H) · Complete scope, Safety#308251032$1802 viol.

Inspection #308251032

Dates

Opened
Feb 14, 2005
Closing Conference Date
Feb 14, 2005
Closed
Jul 27, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$180
Penalties on Record
$180
Site Address
909 N Columbia Blvd, Portland, OR 97217
Industry
312113 Ice Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious12$180$180Feb 14, 2005--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other12$0$0Feb 14, 2005--
Aug 17, 1995Planned (H) · Complete scope, Safety#126689686$5404 viol.

Inspection #126689686

Dates

Opened
Aug 17, 1995
Closing Conference Date
Aug 17, 1995
Closed
Oct 30, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$540
Penalties on Record
$540
Site Address
909 N Columbia Blvd, Portland, OR 97217
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001702022118
OSHA citation code: 702022118 E
Serious21$270$270Jan 12, 1996--
01002702022118
OSHA citation code: 702022118 A
Serious13$270$270Dec 29, 1995--
020031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Other11$0$0Jan 5, 1996--
020041910.303
OSHA citation code: 19100303 B02
Other11$0$0Jan 26, 1996--
Jul 22, 1993Planned (H) · Complete scope, Safety#123774424$2104 viol.

Inspection #123774424

Dates

Opened
Jul 22, 1993
Closing Conference Date
Jul 22, 1993
Closed
Jan 11, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$210
Penalties on Record
$210
Site Address
909 N Columbia Blvd, Portland, OR 97217
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$210$210Jul 22, 1993--
020021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other11$0$0Jul 22, 1993--
020031910.303
OSHA citation code: 19100303 G01 II
Other11$0$0Aug 13, 1993--
020041910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 II
Other13$0$0Aug 17, 1993--
Sep 1, 1992Complaint (B) · Partial scope, Health#123756496$1201 viol.

Inspection #123756496

Dates

Opened
Sep 1, 1992
Closing Conference Date
Sep 1, 1992
Closed
Nov 5, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
2 complaints

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
909 N Columbia Blvd, Portland, OR 97217
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious11$120$120Sep 1, 1992--
Dec 13, 1991Planned (H) · Complete scope, Safety#115719163$1808 viol.

Inspection #115719163

Dates

Opened
Dec 13, 1991
Closing Conference Date
Dec 13, 1991
Closed
Feb 19, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$180
Penalties on Record
$180
Site Address
909 N Columbia Blvd, Portland, OR 97217
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$75$75Dec 13, 1991--
01002763009001Serious16$105$105Jan 21, 1992--
020031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other13$0$0Feb 4, 1992--
020041910.22
OSHA citation code: 19100022 A02
Other212$0$0Jan 10, 1992--
020051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Other13$0$0Jan 10, 1992--
020067127002002Other128$0$0Jan 10, 1992--
020071910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other16$0$0Jan 10, 1992--
020081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 III
Other16$0$0Jan 21, 1992--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus3 citations · $465
1910.3032 citations · $0
1910.304Wiring design and protection2 citations · $0

Industry comparison

BLS 2024 survey: ice manufacturing reported 2.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 29.0%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Portland, OR

All employers in Portland →