LANCASTER METAL MANUFACTURING, INCORPORATED
1548 FRUITVILLE PIKE, LANCASTER, PA 17601 · NAICS 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 12, 2013#339240848Jul 12, 2013Planned (H) · No Inspection scope, Health#339240848$00 viol.0 violations$0 in penalties
Inspection #339240848
Dates
- Opened
- Jul 12, 2013
- Closing Conference Date
- Jul 12, 2013
- Closed
- Jul 12, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 68
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 333414 Heating Equipment (except Warm Air Furnaces) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jun 27, 2006#308478254Jun 27, 2006Planned (H) · Complete scope, Safety#308478254$5,8806 viol.6 violations$5,880 in penalties
Inspection #308478254
Dates
- Opened
- Jun 27, 2006
- Closing Conference Date
- Jul 27, 2006
- Closed
- Sep 8, 2006
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 170
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $9,050
- Penalties on Record
- $5,880
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 D01 III | Serious | 1 | 1 | $1,500 | $970 | Aug 28, 2006 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A02 | Serious | 1 | 1 | $1,275 | $830 | Jul 19, 2006 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 1 | $1,500 | $975 | Aug 28, 2006 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Serious | 1 | 1 | $1,500 | $975 | Aug 28, 2006 | - | - |
| 01005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Serious | 1 | 1 | $2,000 | $1,300 | Aug 28, 2006 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Dec 2, 2004#305843203Dec 2, 2004Complaint (B) · Partial scope, Safety#305843203$00 viol.0 violations$0 in penalties
Inspection #305843203
Dates
- Opened
- Dec 2, 2004
- Closing Conference Date
- Dec 2, 2004
- Closed
- Dec 6, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 154
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Apr 20, 2004#305839771Apr 20, 2004Planned (H) · Complete scope, Health#305839771$2,3255 viol.5 violations$2,325 in penalties
Inspection #305839771
Dates
- Opened
- Apr 20, 2004
- Closing Conference Date
- Apr 22, 2004
- Closed
- Jul 2, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 132
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $3,580
- Penalties on Record
- $2,325
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 10 | $1,500 | $975 | Apr 22, 2004 | - | - |
| 01002 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $955 | $620 | Apr 22, 2004 | - | - |
| 01003 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Serious | 1 | 10 | $1,125 | $730 | Jun 4, 2004 | - | - |
| 02001 | 1910.22 OSHA citation code: 19100022 D01 | Other | 1 | 10 | $0 | $0 | Jun 4, 2004 | - | - |
| 02002 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 III | Other | 1 | 15 | $0 | $0 | May 13, 2004 | - | - |
Feb 26, 2004#112663596Feb 26, 2004Complaint (B) · Partial scope, Safety#112663596$00 viol.0 violations$0 in penalties
Inspection #112663596
Dates
- Opened
- Feb 26, 2004
- Closing Conference Date
- Feb 26, 2004
- Closed
- Feb 27, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 140
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 332313 Plate Work Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Apr 18, 2003#305836629Apr 18, 2003Complaint (B) · Partial scope, Health#305836629$00 viol.0 violations$0 in penalties
Inspection #305836629
Dates
- Opened
- Apr 18, 2003
- Closing Conference Date
- Apr 18, 2003
- Closed
- Apr 18, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 150
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Feb 7, 2003#112990254Feb 7, 2003Planned (H) · Partial scope, Safety#112990254$8302 viol.2 violations$830 in penalties
Inspection #112990254
Dates
- Opened
- Feb 7, 2003
- Closing Conference Date
- Feb 7, 2003
- Closed
- Jul 8, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 128
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $1,275
- Penalties on Record
- $830
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.255 Resistance Welding OSHA citation code: 19100255 B04 | Serious | 1 | 6 | $1,275 | $830 | Jun 23, 2003 | - | - |
| 01001B | 1910.255 Resistance Welding OSHA citation code: 19100255 B05 | Serious | 1 | 6 | $0 | $0 | Apr 18, 2003 | - | - |
Feb 28, 2001#112995709Feb 28, 2001Complaint (B) · Partial scope, Health#112995709$6353 viol.3 violations$635 in penalties
Inspection #112995709
Dates
- Opened
- Feb 28, 2001
- Closing Conference Date
- Feb 28, 2001
- Closed
- Mar 26, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 128
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $975
- Penalties on Record
- $635
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.106 OSHA citation code: 19100106 D02 I | Serious | 1 | 2 | $975 | $635 | Apr 4, 2001 | - | - |
| 01001B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 1 | 2 | $0 | $0 | Apr 4, 2001 | - | - |
| 01001C | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 1 | 2 | $0 | $0 | Apr 4, 2001 | - | - |
Feb 17, 2000#300411675Feb 17, 2000Planned (H) · Complete scope, Health#300411675$00 viol.0 violations$0 in penalties
Inspection #300411675
Dates
- Opened
- Feb 17, 2000
- Closing Conference Date
- Feb 17, 2000
- Closed
- Feb 23, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 142
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Feb 17, 2000#113749956Feb 17, 2000Planned (H) · Complete scope, Safety#113749956$4,4215 viol.5 violations$4,421 in penalties
Inspection #113749956
Dates
- Opened
- Feb 17, 2000
- Closing Conference Date
- Feb 17, 2000
- Closed
- Apr 17, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 142
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $6,800
- Penalties on Record
- $4,421
- Site Address
- 1548 Fruitville Pike, Lancaster, PA 17601
- Industry
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $2,975 | $1,934 | Apr 18, 2000 | - | - |
| 01002 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 V | Serious | 1 | 4 | $1,275 | $829 | Mar 28, 2000 | - | - |
| 01003 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Serious | 2 | 3 | $1,275 | $829 | Mar 28, 2000 | - | - |
| 01004 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G01 III | Serious | 1 | 1 | $1,275 | $829 | Mar 28, 2000 | - | - |
| 02001 | 1910.303 OSHA citation code: 19100303 G01 II | Other | 2 | 2 | $0 | $0 | Mar 28, 2000 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
13 inspections, 1993 to 2013. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Machinery Manufacturing, 17,988 employers with OSHA inspections. Arithmetic from DOL records.