Skip to content
SafetyRecord logoSafetyRecord
LANGENBACH WOOD PRODUCTS, INC.
$5,989
penalties
40
viol.
5
insp.

LANGENBACH WOOD PRODUCTS, INC.

2265 265TH AVENUE, Fort Madison, IA 52627

Inspections
5
Sep 1988 to Dec 2011 · 5 safety, 0 health
Violations
40
across 5 inspections
Penalties on record
$5,989
latest amounts in DOL records
By classification
Serious 30Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 21, 2011Complaint (B) · Partial scope, Safety#316232966$1,1255 viol.

Inspection #316232966

Dates

Opened
Dec 21, 2011
Closing Conference Date
Jan 3, 2012
Closed
Mar 27, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$1,125
Penalties on Record
$1,125
Site Address
2265 265th Avenue, Fort Madison, IA 52627
Industry
321113 Sawmills

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001880004Serious33$375$375Feb 28, 2012--
01002A1910.303
OSHA citation code: 19100303 B02
Serious22$375$375Feb 28, 2012--
01002B1910.303
OSHA citation code: 19100303 G02 I
Serious12$0$0Feb 28, 2012--
01003A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious12$375$375Feb 28, 2012--
01003B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 IVA
Serious32$0$0Feb 28, 2012--
Jun 2, 2011Planned (H) · Partial scope, Safety#315682070$1131 viol.

Inspection #315682070

Dates

Opened
Jun 2, 2011
Closing Conference Date
Jun 2, 2011
Closed
Aug 12, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$225
Penalties on Record
$113
Site Address
2265 265th Avenue, Fort Madison, IA 52627
Industry
321113 Sawmills

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious12$225$113Jul 28, 2011--
Jan 21, 2004Planned (H) · Complete scope, Safety#306680760$1,0014 viol.

Inspection #306680760

Dates

Opened
Jan 21, 2004
Closing Conference Date
Jan 29, 2004
Closed
Mar 3, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$2,000
Penalties on Record
$1,001
Site Address
2265 265th Avenue, Fort Madison, IA 52627
Industry
321113 Sawmills

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious118$375$188Feb 19, 2004--
010021910.303
OSHA citation code: 19100303 B02
Serious13$500$250Feb 19, 2004--
010031910.303
OSHA citation code: 19100303 F
Serious418$500$250Feb 19, 2004--
010041910.303
OSHA citation code: 19100303 G02 I
Serious117$625$313Feb 19, 2004--
Dec 13, 2000Referral (C) · Partial scope, Safety#303738280$3,50024 viol.

Inspection #303738280

Dates

Opened
Dec 13, 2000
Closing Conference Date
Dec 28, 2000
Closed
Mar 27, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 referral

Violations and Penalties

Total Violations
24
Violation Types
15 serious, 9 other-than-serious
Initial Penalties
$9,000
Penalties on Record
$3,500
Site Address
2265 265th Avenue, Fort Madison, IA 52627
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

AmputationHospitalizationNov 7, 2000

Employee's hand amputated in rip saw

Injury: AmputationBody part: Hand(s)Source: MachineEvent: Caught In or Between

Violations

Violation list (10 of 24 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious123$2,500$850Mar 20, 2001--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 II
Serious123$0$0Mar 20, 2001--
01001C1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious123$0$0Mar 20, 2001--
01001D1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious123$0$0Mar 20, 2001--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious223$750$300Feb 5, 2001--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious423$1,250$550Feb 5, 2001--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious323$0$0Feb 5, 2001--
01003C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious123$0$0Feb 5, 2001--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious323$1,250$550Feb 5, 2001--
01005A1910.303
OSHA citation code: 19100303 B02
Serious123$1,250$550Feb 5, 2001--

Showing the 10 violations listed first by citation identifier. This inspection has 24 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 27, 1988Planned (H) · Complete scope, Safety#104221445$2506 viol.

Inspection #104221445

Dates

Opened
Sep 27, 1988
Closing Conference Date
Sep 27, 1988
Contested
Oct 31, 1988
Final Order
Jan 18, 1989
Closed
Jan 18, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$630
Penalties on Record
$250
Site Address
2265 265th Avenue, Fort Madison, IA 52627
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other13$90$0Nov 21, 1988Oct 31, 1988Jan 18, 1989
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious622$180$75Nov 21, 1988Oct 31, 1988Jan 18, 1989
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03I
Serious83$0$0Nov 21, 1988Oct 31, 1988Jan 18, 1989
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious513$210$75Nov 21, 1988Oct 31, 1988Jan 18, 1989
010041910.265
Sawmills
OSHA citation code: 19100265 E01V
Serious13$90$50Nov 21, 1988Oct 31, 1988Jan 18, 1989
010051910.303
OSHA citation code: 19100303 G02 I
Serious12$60$50Nov 21, 1988Oct 31, 1988Jan 18, 1989
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus8 citations · $1,363
1910.305Wiring methods, components, and equipment for general use8 citations · $475
1910.3037 citations · $1,788

Industry comparison

BLS 2024 survey: sawmills reported 4.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Fort Madison, IA

All employers in Fort Madison →