LENZE AC TECH CORPORATION
630 DOUGLAS STREET, UXBRIDGE, MA 01569 · NAICS 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 8, 2013#339004319Apr 8, 2013Referral (C) · Partial scope, Safety#339004319$7,2505 viol.5 violations$7,250 in penalties
Inspection #339004319
Dates
- Opened
- Apr 8, 2013
- Closing Conference Date
- Apr 8, 2013
- Final Order
- Jun 13, 2013
- Closed
- Aug 19, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15,000
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 1 serious, 4 other-than-serious
- Initial Penalties
- $14,500
- Penalties on Record
- $7,250
- Site Address
- 630 Douglas St., Uxbridge, MA 01569
- Industry
- 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D01 | Other | 1 | 13 | $3,750 | $500 | May 31, 2013 | - | Jun 13, 2013 |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II B | Serious | 1 | 13 | $3,750 | $6,000 | Jun 21, 2013 | - | Jun 13, 2013 |
| 01003A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A02 X | Other | 1 | 13 | $7,000 | $750 | May 20, 2013 | - | Jun 13, 2013 |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Other | 1 | 13 | $0 | $0 | May 20, 2013 | - | Jun 13, 2013 |
| 01003C | 1910.333 Electrical - Selection and Use of Work Practices OSHA citation code: 19100333 A | Other | 1 | 13 | $0 | $0 | May 31, 2013 | - | Jun 13, 2013 |
Sep 17, 2010#313206831Sep 17, 2010Complaint (B) · Partial scope, Health#313206831$1,2601 viol.1 violation$1,260 in penalties
Inspection #313206831
Dates
- Opened
- Sep 17, 2010
- Closing Conference Date
- Oct 4, 2010
- Closed
- Dec 10, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 370
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $1,800
- Penalties on Record
- $1,260
- Site Address
- 630 Douglas Street, Uxbridge, MA 01569
- Industry
- 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Toluene | 1 | 0.44067 | ppm |
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Other | 1 | 2 | $1,800 | $1,260 | Dec 2, 2010 | - | - |
Aug 6, 2010#313206203Aug 6, 2010Complaint (B) · Partial scope, Health#313206203$00 viol.0 violations$0 in penalties
Inspection #313206203
Dates
- Opened
- Aug 6, 2010
- Closing Conference Date
- Sep 28, 2010
- Closed
- Oct 27, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 370
- Related Activity
- 1 complaint, 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 630 Douglas Street, Uxbridge, MA 01569
- Industry
- 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 2 | 0 | mg/m³ |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 2010 to 2013. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Electrical Equipment, Appliance, and Component Manufacturing, 4,599 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: all other miscellaneous electrical equipment and component manufacturing reported 1.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 21.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source