Skip to content
SafetyRecord logoSafetyRecord
LIST INDUSTRIES INC.
$212,495
penalties
67
viol.
15
insp.

LIST INDUSTRIES INC.

401 NW 12TH AVE., DEERFIELD BEACH, FL 33442

Inspections
15
Nov 1989 to Oct 2023 · 10 safety, 5 health
Violations
67
across 15 inspections
Penalties on record
$212,495
latest amounts in DOL records
By classification
Serious 47Willful 0Repeat 5Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 19, 2023Referral (C) · Partial scope, Safety#347046799$12,9051 viol.

Inspection #347046799

Dates

Opened
Oct 19, 2023
Closing Conference Date
Apr 5, 2024
Final Order
May 6, 2024
Closed
Jun 24, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
170
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$16,131
Penalties on Record
$12,905
Site Address
401 Jim Moran Boulevard, Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.255
Resistance Welding
OSHA citation code: 19100255 B04
Serious13$16,131$12,905May 28, 2024-May 6, 2024
Jul 8, 2020Referral (C) · Partial scope, Safety#344824313$72,8496 viol.

Inspection #344824313

Dates

Opened
Jul 8, 2020
Closing Conference Date
Sep 21, 2020
Final Order
Dec 3, 2020
Closed
Dec 1, 2021

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
210
Related Activity
1 referral

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 repeat
Initial Penalties
$106,796
Penalties on Record
$72,849
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

HospitalizationJul 1, 2020

Employee's finger is crushed in punch press

Event: Caught In or Between

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious13$8,482$5,089-Dec 3, 2020
01001B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious13$0$0-Dec 3, 2020
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious13$10,603$6,362-Dec 3, 2020
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$0$0-Dec 3, 2020
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious11$13,494$9,446-Dec 3, 2020

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 28, 2019Referral (C) · Partial scope, Safety#344411889$5,7801 viol.

Inspection #344411889

Dates

Opened
Oct 28, 2019
Closing Conference Date
Oct 28, 2019
Final Order
May 11, 2020
Closed
May 27, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
500
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$9,639
Penalties on Record
$5,780
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

HospitalizationOct 24, 2019

Employee's fingertip is amputated in power press

Event: Caught In or Between

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$9,639$5,780May 12, 2020-May 11, 2020
Jan 20, 2017Referral (C) · Partial scope, Safety#342040805$00 viol.

Inspection #342040805

Dates

Opened
Jan 20, 2017
Closing Conference Date
Feb 2, 2017
Closed
Feb 2, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
401 Jim Moran Blvd, Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Oct 14, 2016Planned (H) · Complete scope, Health#341848935$10,8647 viol.

Inspection #341848935

Dates

Opened
Oct 14, 2016
Closing Conference Date
Oct 14, 2016
Final Order
May 1, 2017
Closed
Dec 6, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
5 serious, 2 other-than-serious
Initial Penalties
$10,864
Penalties on Record
$10,864
Site Address
401 Jim Moran Blvd, Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious340$5,432$5,432-May 1, 2017
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 II B
Serious11$0$0Apr 10, 2017-May 1, 2017
01001C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 II C
Serious11$0$0-May 1, 2017
01001D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious140$0$0Apr 24, 2017-May 1, 2017
010021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01 I
Serious14$5,432$5,432Apr 10, 2017-May 1, 2017

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 21, 2012Planned (H) · Complete scope, Safety#335954392$16,2186 viol.

Inspection #335954392

Dates

Opened
Aug 21, 2012
Closing Conference Date
Aug 31, 2012
Final Order
Nov 1, 2012
Closed
Mar 19, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
150

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$16,218
Penalties on Record
$16,218
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$3,366$3,366Oct 26, 2012-Nov 1, 2012
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious12$3,366$3,366-Nov 1, 2012
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious12$3,366$3,366-Nov 1, 2012
010041910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious14$3,060$3,060-Nov 1, 2012
010051910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 IV
Serious12$3,060$3,060-Nov 1, 2012

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 13, 2011Referral (C) · Partial scope, Safety#315359257$32,9002 viol.

Inspection #315359257

Dates

Opened
Dec 13, 2011
Closing Conference Date
Dec 14, 2011
Closed
Mar 19, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 repeat
Initial Penalties
$56,000
Penalties on Record
$32,900
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 IV
Serious24$7,000$3,500Mar 1, 2012--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Repeat14$49,000$29,400Feb 27, 2012--
Oct 15, 2008Complaint (B) · Partial scope, Health#312149941$26,3254 viol.

Inspection #312149941

Dates

Opened
Oct 15, 2008
Closing Conference Date
Feb 23, 2009
Closed
Mar 17, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
420
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 repeat
Initial Penalties
$40,500
Penalties on Record
$26,325
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium40mg/m³
Chromic Acid and Chromates (as CrO3)40mg/m³
Chromium, Metal and Insoluble Salts40mg/m³
Chromium (VI) - TWA40mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40 - 0.013673mg/m³
Iron Oxide Fume40mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious15$1,500$975Mar 19, 2009--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious12$1,500$975Feb 26, 2009--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat33$25,000$16,250Mar 19, 2009--
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Repeat12$12,500$8,125Mar 5, 2009--
Jun 14, 2007Referral (C) · Partial scope, Safety#311082176$13,5003 viol.

Inspection #311082176

Dates

Opened
Jun 14, 2007
Closing Conference Date
Jun 15, 2007
Closed
Oct 24, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
270
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$13,500
Penalties on Record
$13,500
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

AmputationHospitalizationJun 6, 2007

Employee amputates fingers in power press

Injury: AmputationBody part: Finger(s)Source: Bodily MotionEvent: Caught In or Between

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious13$3,500$3,500Aug 27, 2007--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious13$5,000$5,000Sep 4, 2007--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C08
Serious13$5,000$5,000Aug 27, 2007--
Mar 26, 2007Planned (H) · Complete scope, Safety#310216858$4,2194 viol.

Inspection #310216858

Dates

Opened
Mar 26, 2007
Closing Conference Date
Mar 27, 2007
Closed
Apr 30, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
180

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$5,625
Penalties on Record
$4,219
Site Address
401 Jim Moran Blvd., Deerfield Beach, FL 33442
Industry
337215 Showcase, Partition, Shelving, and Locker Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious12$1,875$1,407May 7, 2007--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,875$1,406Apr 16, 2007--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious12$1,875$1,406May 7, 2007--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other120$0$0May 7, 2007--
Inspections 1 to 10 of 15, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure9 citations · $6,257
1910.212General Requirements for All Machines (Machine Guarding)9 citations · $81,994
1910.217Mechanical Power Presses8 citations · $45,731

Chemical exposure sampling

Samples
160
Substances
21
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

BLS 2024 survey: showcase, partition, shelving, and locker manufacturing reported 4.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.6%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in DEERFIELD BEACH, FL