Skip to content
SafetyRecord logoSafetyRecord
LITTLE SILVER ELECTRIC
$1,182
penalties
3
viol.
3
insp.

LITTLE SILVER ELECTRIC

HEXGON BUILDING, FT. MONMOUTH, TINTON AVENUE, TINTON FALLS, NJ 07703

Inspections
3
Mar 1985 to Apr 2003 · 2 safety, 1 health
Violations
3
across 3 inspections
Penalties on record
$1,182
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 16, 2003Programmed Related (I) · Partial scope, Safety#306337932$7882 viol.

Inspection #306337932

Dates

Opened
Apr 16, 2003
Closing Conference Date
Apr 16, 2003
Closed
May 30, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,050
Penalties on Record
$788
Site Address
Seabrook Village, Tinton Falls, NJ 07753
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious11$525$394May 6, 2003--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 II
Serious22$525$394May 6, 2003--
Oct 3, 2001Programmed Related (I) · Partial scope, Safety#303393391$3941 viol.

Inspection #303393391

Dates

Opened
Oct 3, 2001
Closing Conference Date
Oct 3, 2001
Closed
Jan 24, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
95

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$525
Penalties on Record
$394
Site Address
Seabrook Village, Tinton Falls, NJ 07753
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Serious11$525$394Oct 29, 2001--
Mar 19, 1985Complaint (B) · Partial scope, Health#986729$00 viol.

Inspection #986729

Dates

Opened
Mar 19, 1985
Closing Conference Date
Mar 19, 1985
Closed
Jan 15, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
40
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hexgon Building, Ft. Monmouth, Tinton Avenue, Tinton Falls, NJ 07703
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)3 citations · $1,182

Industry comparison

BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in TINTON FALLS, NJ

All employers in TINTON FALLS →