Skip to content
SafetyRecord logoSafetyRecord
LLOYD CONSTRUCTION COMPANY INC.
$4,200
penalties
14
viol.
27
insp.

LLOYD CONSTRUCTION COMPANY INC.

975 N SILVERBELL, TUCSON, AZ 85745

Inspections
27
Apr 1992 to Dec 2020 · 22 safety, 5 health
Violations
14
across 27 inspections
Penalties on record
$4,200
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 5, 1997Planned (H) · Partial scope, Safety#126994789$00 viol.

Inspection #126994789

Dates

Opened
Mar 5, 1997
Closing Conference Date
Mar 5, 1997
Closed
Mar 10, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1000 North Tucson Blvd., Himmel Park (pool), Tucson, AZ 85716
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 25, 1996Planned (H) · Partial scope, Safety#126993823$00 viol.

Inspection #126993823

Dates

Opened
Nov 25, 1996
Closing Conference Date
Nov 25, 1996
Closed
Nov 25, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3725 N. Flowing Wells Rd., Tucson, AZ 85705
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 31, 1996Follow-Up (F) · Partial scope, Health#126993062$00 viol.

Inspection #126993062

Dates

Opened
Jul 31, 1996
Closing Conference Date
Jul 31, 1996
Closed
Jul 31, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3255 West 21st Street, Tucson, AZ 85711
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 15, 1996Planned (H) · Complete scope, Health#126992155$1,2503 viol.

Inspection #126992155

Dates

Opened
May 15, 1996
Closing Conference Date
May 15, 1996
Contested
Jul 19, 1996
Final Order
Mar 27, 1997
Closed
May 21, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
90

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$2,500
Penalties on Record
$1,250
Site Address
3255 West 21st Street, Tucson, AZ 85711
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious11$1,250$625Jul 7, 1996Jul 19, 1996Mar 27, 1997
010021926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious210$1,250$625Jul 7, 1996Jul 19, 1996Mar 27, 1997
020011926.59
Hazard Communication
OSHA citation code: 19260059 H
Other11$0$0Jul 7, 1996Jul 19, 1996Mar 27, 1997
May 15, 1996Planned (H) · Complete scope, Health#126992148$4501 viol.

Inspection #126992148

Dates

Opened
May 15, 1996
Closing Conference Date
May 15, 1996
Closed
Jul 24, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$600
Penalties on Record
$450
Site Address
3255 West 21st Street, Tucson, AZ 85711
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious24$600$450Jun 29, 1996--
Nov 3, 1994Planned (H) · Complete scope, Safety#115619652$01 viol.

Inspection #115619652

Dates

Opened
Nov 3, 1994
Closing Conference Date
Nov 3, 1994
Closed
Apr 28, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2760 East Airport Drive, Tucson, AZ 85706
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.350
Gas Welding and Cutting
OSHA citation code: 19260350 J
Other11$0$0Dec 17, 1994--
Apr 29, 1992Planned (H) · Complete scope, Safety#115593618$02 viol.

Inspection #115593618

Dates

Opened
Apr 29, 1992
Closing Conference Date
Apr 29, 1992
Closed
Jun 8, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
975 N Silverbell, Tucson, AZ 85745
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Other15$0$0May 11, 1992--
010021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other15$0$0May 11, 1992--
Inspections 21 to 27 of 27, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.701Concrete and Masonry Construction - General Requirements3 citations · $1,075
1926.405Electrical - Wiring Methods (Construction)2 citations · $0
1926.350Gas Welding and Cutting2 citations · $0

Other inspected employers in TUCSON, AZ

All employers in TUCSON →