Skip to content
SafetyRecord logoSafetyRecord
LORMAN IRON & METAL CO., INC.
$5,807
penalties
22
viol.
5
insp.

LORMAN IRON & METAL CO., INC.

115 LOMAN STREET, Fort Atkinson, WI 53538

Inspections
5
Apr 1974 to Jan 2007 · 2 safety, 3 health
Violations
22
across 5 inspections
Penalties on record
$5,807
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 12, 2007Planned (H) · Complete scope, Health#308387836$3,7826 viol.

Inspection #308387836

Dates

Opened
Jan 12, 2007
Closing Conference Date
Mar 13, 2007
Closed
Mar 28, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$5,400
Penalties on Record
$3,782
Site Address
115 Lorman Street, Fort Atkinson, WI 53538
Industry
423930 Recyclable Material Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30.0110539 - 0.3559557mg/m³
Gravimetric DeterminationQC30.1799 - 1.1066mg/m³
Iron Oxide Fume30.0269196 - 0.0932018mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Particulates not otherwise regulated (Total Dust)30.1799 - 1.1066mg/m³
Sample WeightQC30.145 - 0.799mg
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30mg/m³

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
General requirements
OSHA citation code: 19100132 D01 I
Serious11$1,125$788Mar 20, 2007--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 E01
Serious11$1,125$788Mar 20, 2007--
010031910.335
Electrical - Safeguards
OSHA citation code: 19100335 A01 I
Serious12$1,125$788Mar 20, 2007--
010041910.335
Electrical - Safeguards
OSHA citation code: 19100335 A02 II
Serious22$1,125$788Mar 21, 2007--
010051910.1025
Lead
OSHA citation code: 19101025 H01
Serious11$900$630Mar 21, 2007--
020011910.1025
Lead
OSHA citation code: 19101025 D02
Other11$0$0Mar 20, 2007--
Feb 24, 2000Unprogrammed Related (G) · Partial scope, Health#300570223$00 viol.

Inspection #300570223

Dates

Opened
Feb 24, 2000
Closing Conference Date
Mar 15, 2000
Closed
Mar 21, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
115 Lorman Street, Fort Atkinson, WI 53538
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jul 14, 1993Planned (H) · Complete scope, Health#105944219$9509 viol.

Inspection #105944219

Dates

Opened
Jul 14, 1993
Closing Conference Date
Jul 16, 1993
Closed
Oct 14, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
9
Violation Types
7 serious, 2 other-than-serious
Initial Penalties
$950
Penalties on Record
$950
Site Address
115 Lorman St., Fort Atkinson, WI 53538
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30 - 0.0362mg/m³
Iron Oxide Fume30 - 0.2464mg/m³
Lead, Inorganic (as Pb)30 - 0.0093mg/m³
Manganese Fume (as Mn)30 - 0.002mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30 - 0.0163mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
OSHA citation code: 19100023 C01
Serious14$275$275Aug 24, 1993--
01001B1910.23
OSHA citation code: 19100023 D01 I
Serious11$0$0Aug 24, 1993--
01001C1910.24
OSHA citation code: 19100024 D
Serious14$0$0Aug 24, 1993--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious14$275$275Oct 22, 1993--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Serious440$0$0Oct 22, 1993--
01003A1910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious22$400$400Jul 27, 1993--
01003B1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious24$0$0Jul 27, 1993--
020011904.2
OSHA citation code: 19040002 A
Other210$0$0Aug 2, 1993--
020021910.38
OSHA citation code: 19100038 A05 III
Other11$0$0Oct 22, 1993--
Mar 6, 1991Complaint (B) · Partial scope, Safety#102510443$1,0252 viol.

Inspection #102510443

Dates

Opened
Mar 6, 1991
Closing Conference Date
Mar 6, 1991
Closed
May 13, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,025
Penalties on Record
$1,025
Site Address
115 Lorman St., Fort Atkinson, WI 53538
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$1,125$125Apr 11, 1991--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 E01
Serious12$900$900May 6, 1991--
Apr 17, 1974Planned (H) · Complete scope, Safety#15505761$505 viol.

Inspection #15505761

Dates

Opened
Apr 17, 1974
Closing Conference Date
Apr 17, 1974
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
70

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$50
Penalties on Record
$50
Site Address
115 Loman Street, Fort Atkinson, WI 53538
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D03 IV
Other1-$0$0Apr 30, 1974--
010021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 K01
Other1-$25$25Jun 17, 1974--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other1-$0$0May 13, 1974--
010041910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Other1-$25$25Jun 17, 1974--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other2-$0$0May 23, 1974--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead2 citations · $630
1910.232 citations · $275
1910.95Occupational Noise Exposure2 citations · $275

Chemical exposure sampling

Samples
83
Substances
16
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

BLS 2024 survey: recyclable material merchant wholesalers reported 3.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.0%; NAICS 42393 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Fort Atkinson, WI