Skip to content
SafetyRecord logoSafetyRecord
LORMAR MANUFACTURING, INC.
$2,175
penalties
16
viol.
3
insp.

LORMAR MANUFACTURING, INC.

115 S MATHER ST, LEROY, MN 55951

Inspections
3
Dec 1994 to May 1995 · 2 safety, 1 health
Violations
16
across 3 inspections
Penalties on record
$2,175
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 19, 1995Follow-Up (F) · Partial scope, Safety#120407648$00 viol.

Inspection #120407648

Dates

Opened
May 19, 1995
Closing Conference Date
May 19, 1995
Closed
Jul 19, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
115 S Mather St, Leroy, MN 55951
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 17, 1995Referral (C) · Partial scope, Health#120410816$00 viol.

Inspection #120410816

Dates

Opened
Jan 17, 1995
Closing Conference Date
Jan 17, 1995
Closed
Feb 23, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
115 S Mather St, Leroy, MN 55951
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Dec 15, 1994Complaint (B) · Complete scope, Safety#120380191$2,17516 viol.

Inspection #120380191

Dates

Opened
Dec 15, 1994
Closing Conference Date
Dec 15, 1994
Contested
Jan 19, 1995
Closed
Nov 14, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 complaint

Violations and Penalties

Total Violations
16
Violation Types
15 serious, 1 other-than-serious
Initial Penalties
$11,025
Penalties on Record
$2,175
Site Address
115 S Mather St, Leroy, MN 55951
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Enforcement Outcome

Citation contest activity appears on Jan 19, 1995. Final orders are recorded through May 18, 1995. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
Stairways
OSHA citation code: 19100025 D02 XII
Serious11$525$75Mar 21, 1995Jan 19, 1995May 18, 1995
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Serious17$175$25Mar 21, 1995Jan 19, 1995May 18, 1995
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious16$1,050$150Mar 21, 1995Jan 19, 1995May 18, 1995
010041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C03
Serious16$1,750$250Mar 21, 1995Jan 19, 1995May 18, 1995
010051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious16$1,050$150Mar 21, 1995Jan 19, 1995May 18, 1995
010061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Serious17$525$525Mar 21, 1995--
010071910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious11$1,050$150Jan 20, 1995Jan 19, 1995May 18, 1995
010081910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious11$525$75Jan 20, 1995Jan 19, 1995May 18, 1995
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious57$1,050$150Mar 21, 1995Jan 19, 1995May 18, 1995
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious11$525$75Mar 21, 1995Jan 19, 1995May 18, 1995
010115205067501Serious11$875$125Feb 3, 1995Jan 19, 1995May 18, 1995
010125205.850Serious33$700$100Mar 21, 1995Jan 19, 1995May 18, 1995
010135206070001Serious17$700$100Mar 21, 1995Jan 19, 1995May 18, 1995
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious11$175$175Mar 21, 1995--
020025210.420Serious17$350$50Jan 21, 1995Jan 19, 1995May 18, 1995
02003182065308Other17$0$0Mar 21, 1995--

Failure to Abate Penalties2 citations, $3,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01013#120407648Jul 17, 1995$2,500Jul 25, 1995Oct 13, 1995
02003#120407648Jul 17, 1995$500Jul 25, 1995Oct 13, 1995
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $550
1910.25Stairways1 citation · $75
1910.37Maintenance, Safeguards, and Operational Features for Exit Routes1 citation · $25

Other inspected employers in LEROY, MN