MARROS EQUIP. & TRUCKS INC.
MOUND RD. RT. 414, WATERLOO, NY 13165
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 2, 1988#102648730Jun 2, 1988Planned (H) · Complete scope, Safety#102648730$81019 viol.19 violations$810 in penalties
Inspection #102648730
Dates
- Opened
- Jun 2, 1988
- Closing Conference Date
- Jun 2, 1988
- Closed
- Aug 5, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 19
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 11 serious, 8 other-than-serious
- Initial Penalties
- $810
- Penalties on Record
- $810
- Site Address
- Mound Rd. Rt. 414, Waterloo, NY 13165
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (19 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C05 | Serious | 2 | 2 | $150 | $150 | Jul 8, 1988 | - | - |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 1 | $90 | $90 | Jul 8, 1988 | - | - |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 2 | 1 | $0 | $0 | Jul 8, 1988 | - | - |
| 01003 | 1910.243 Guarding of Portable Powered Tools OSHA citation code: 19100243 C01 | Serious | 4 | 4 | $120 | $120 | Jul 8, 1988 | - | - |
| 01004A | 1910.252 General requirements OSHA citation code: 19100252 A02 IIB | Serious | 9 | 4 | $90 | $90 | Jul 8, 1988 | - | - |
| 01004B | 1910.252 General requirements OSHA citation code: 19100252 A02 IID | Serious | 1 | 1 | $0 | $0 | Jul 8, 1988 | - | - |
| 01004C | 1910.252 General requirements OSHA citation code: 19100252 A02 IVC | Serious | 1 | 3 | $0 | $0 | Jul 8, 1988 | - | - |
| 01005 | 1910.303 OSHA citation code: 19100303 G02 I | Serious | 1 | 2 | $150 | $150 | Jul 8, 1988 | - | - |
| 01006 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F04 | Serious | 5 | 5 | $120 | $120 | Jul 8, 1988 | - | - |
| 01007A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 10 | $90 | $90 | Jul 8, 1988 | - | - |
| 01007B | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 10 | $0 | $0 | Jul 8, 1988 | - | - |
| 02001 | 1904.2 OSHA citation code: 19040002 A | Other | 1 | 10 | $0 | $0 | Jun 24, 1988 | - | - |
| 02002 | 1910.22 OSHA citation code: 19100022 B01 | Other | 1 | 4 | $0 | $0 | Jul 8, 1988 | - | - |
| 02003 | 1910.37 OSHA citation code: 19100037 Q01 | Other | 3 | 6 | $0 | $0 | Jul 8, 1988 | - | - |
| 02004 | 1910.141 Sanitation OSHA citation code: 19100141 A03 I | Other | 3 | 10 | $0 | $0 | Jul 8, 1988 | - | - |
| 02005 | 1910.303 OSHA citation code: 19100303 F | Other | 2 | 1 | $0 | $0 | Jul 8, 1988 | - | - |
| 02006 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Other | 3 | 3 | $0 | $0 | Jul 8, 1988 | - | - |
| 02007 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B02 | Other | 1 | 1 | $0 | $0 | Jul 8, 1988 | - | - |
| 02008 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 II | Other | 1 | 1 | $0 | $0 | Jul 8, 1988 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.