Skip to content
SafetyRecord logoSafetyRecord
MEADVILLE REDI-MIX CONCRETE
$9,695
penalties
21
viol.
8
insp.

MEADVILLE REDI-MIX CONCRETE

ROUTE 322 R D 6, Meadville, PA 16335NAICS 327320 Ready-Mix Concrete Manufacturing

Inspections
8
Aug 1983 to Feb 2018 · 7 safety, 1 health
Violations
21
across 8 inspections
Penalties on record
$9,695
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 2Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 1, 2018Planned (H) · Partial scope, Safety#342924024$00 viol.

Inspection #342924024

Dates

Opened
Feb 1, 2018
Closing Conference Date
Not recorded
Closed
Mar 7, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
19824 Conchranton Road, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 2, 2006Programmed Related (I) · Complete scope, Safety#113171003$00 viol.

Inspection #113171003

Dates

Opened
Feb 2, 2006
Closing Conference Date
Feb 2, 2006
Closed
Feb 2, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Student Housing Complex, Highland Avenue, Meadville, PA 16335
Industry
238110 Poured Concrete Foundation and Structure Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 5, 2005Planned (H) · Partial scope, Safety#306457656$4554 viol.

Inspection #306457656

Dates

Opened
Oct 5, 2005
Closing Conference Date
Oct 5, 2005
Closed
May 16, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$700
Penalties on Record
$455
Site Address
19824 Cochranton Road, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious13$700$455May 8, 2006--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious13$0$0May 8, 2006--
01001C1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious13$0$0May 8, 2006--
020011904.5
OSHA citation code: 19040005 B
Other25$0$0Feb 22, 2006--
Jul 25, 2005Programmed Related (I) · Partial scope, Safety#306458829$2401 viol.

Inspection #306458829

Dates

Opened
Jul 25, 2005
Closing Conference Date
Jul 25, 2005
Closed
Aug 2, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$375
Penalties on Record
$240
Site Address
764 Bessemer Commerce Park, Suite 105, Meadville, PA 16335
Industry
238110 Poured Concrete Foundation and Structure Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.601
Motor Vehicles
OSHA citation code: 19260601 B04
Serious12$375$240Aug 13, 2005--
Aug 16, 2001FatalityAccident (A) · Partial scope, Safety#303706683$6,0002 viol.

Inspection #303706683

Dates

Opened
Aug 16, 2001
Closing Conference Date
Sep 4, 2001
Closed
Nov 7, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
37
Related Activity
1 accident

Violations and Penalties

Total Violations
2
Violation Types
2 repeat
Initial Penalties
$6,000
Penalties on Record
$6,000
Site Address
19824 Cochranton Road, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityAug 15, 2001

Employee killed in fall into concrete aggregate bin

Injury: ConcussionBody part: HeadSource: PersonEvent: Fall (Same Level)

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Repeat14$6,000$6,000Oct 16, 2001--
01001B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D01
Repeat14$0$0Oct 16, 2001--
Apr 23, 2001Planned (H) · Partial scope, Health#303705768$3,00014 viol.

Inspection #303705768

Dates

Opened
Apr 23, 2001
Closing Conference Date
Apr 23, 2001
Closed
Jul 11, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
22

Violations and Penalties

Total Violations
14
Violation Types
7 serious, 7 other-than-serious
Initial Penalties
$6,300
Penalties on Record
$3,000
Site Address
19824 Cochranton Road, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.22
OSHA citation code: 19100022 A01
Serious12$1,575$1,000Jul 18, 2001--
01001B1910.23
OSHA citation code: 19100023 E02
Serious11$0$0Jul 18, 2001--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious11$3,000$1,300Jul 18, 2001--
01002B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D01
Serious11$0$0Jul 18, 2001--
01002C1910.22
OSHA citation code: 19100022 C
Serious11$0$0Jul 18, 2001--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$675$500Jul 18, 2001--

Showing the 6 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 28, 1986Planned (H) · Records Only scope, Safety#17472903$00 viol.

Inspection #17472903

Dates

Opened
Jan 28, 1986
Closing Conference Date
Jan 28, 1986
Closed
Feb 3, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
P.o. Box 418, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 30, 1983Planned (H) · Records Only scope, Safety#12850350$00 viol.

Inspection #12850350

Dates

Opened
Aug 30, 1983
Closing Conference Date
Aug 30, 1983
Closed
Sep 1, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Route 322 R D 6, Meadville, PA 16335
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection4 citations · $100
1910.146Permit-Required Confined Spaces4 citations · $7,300
1910.147The control of hazardous energy (lockout/tagout)2 citations · $455

Industry comparison

Violations per inspection
This employer2.6
Industry average3.3
Penalties per inspection
This employer$1,212
Industry average$2,354

Nonmetallic Mineral Product Manufacturing, 16,983 employers with OSHA inspections. Arithmetic from DOL records.