Skip to content
SafetyRecord logoSafetyRecord
MEXICO CSD ELEM SCHOOL
$0
penalties
20
viol.
8
insp.

MEXICO CSD ELEM SCHOOL

26 ACADEMY ST, MEXICO, NY 13114

Inspections
8
Dec 1990 to Mar 2015 · 8 safety, 0 health
Violations
20
across 8 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 27, 2015Follow-Up (F) · Partial scope, Safety#340503606$00 viol.

Inspection #340503606

Dates

Opened
Mar 27, 2015
Closing Conference Date
Mar 27, 2015
Closed
Mar 27, 2015

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
71

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 23, 2015Planned (H) · Complete scope, Safety#340205632$04 viol.

Inspection #340205632

Dates

Opened
Jan 23, 2015
Closing Conference Date
Jan 23, 2015
Final Order
Mar 6, 2015
Closed
Mar 27, 2015

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
71

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Serious171$0$0Mar 30, 2015-Mar 6, 2015
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV A
Serious171$0$0Mar 30, 2015-Mar 6, 2015
010031910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 I
Serious271$0$0Mar 30, 2015-Mar 6, 2015
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 A04
Other371$0$0Mar 30, 2015-Mar 6, 2015
Feb 17, 2011Follow-Up (F) · Partial scope, Safety#313567190$00 viol.

Inspection #313567190

Dates

Opened
Feb 17, 2011
Closing Conference Date
Feb 17, 2011
Closed
Feb 17, 2011

Inspection

Advance Notice
Yes
Owner Type
Local government
Union Status
Yes
Number of Employees
69

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 30, 2010Planned (H) · Complete scope, Safety#313566580$07 viol.

Inspection #313566580

Dates

Opened
Nov 30, 2010
Closing Conference Date
Nov 30, 2010
Closed
Feb 17, 2011

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
69

Violations and Penalties

Total Violations
7
Violation Types
5 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 IB
Serious269$0$0Mar 11, 2011--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IX
Serious169$0$0Mar 11, 2011--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious1269$0$0Mar 11, 2011--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02 I
Serious369$0$0Mar 11, 2011--
010051910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious169$0$0Mar 11, 2011--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other169$0$0Mar 11, 2011--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 18, 2004Follow-Up (F) · Partial scope, Safety#307658211$00 viol.

Inspection #307658211

Dates

Opened
Nov 18, 2004
Closing Conference Date
Nov 18, 2004
Closed
Nov 18, 2004

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
42

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 1, 2004Planned (H) · Complete scope, Safety#307657791$05 viol.

Inspection #307657791

Dates

Opened
Oct 1, 2004
Closing Conference Date
Oct 1, 2004
Closed
Nov 18, 2004

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
42

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
611110 Elementary and Secondary Schools

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 A08
Serious110$0$0Dec 2, 2004--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious110$0$0Nov 2, 2004--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 E01 IV
Serious110$0$0Nov 2, 2004--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious110$0$0Dec 2, 2004--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other110$0$0Dec 2, 2004--
Feb 14, 1991Follow-Up (F) · Partial scope, Safety#104955000$00 viol.

Inspection #104955000

Dates

Opened
Feb 14, 1991
Closing Conference Date
Feb 14, 1991
Closed
Feb 14, 1991

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 12, 1990Planned (H) · Complete scope, Safety#104954250$04 viol.

Inspection #104954250

Dates

Opened
Dec 12, 1990
Closing Conference Date
Dec 12, 1990
Closed
Feb 19, 1991

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
40

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
26 Academy St, Mexico, NY 13114
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious110$0$0Mar 8, 1991--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious110$0$0Mar 8, 1991--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F01
Serious110$0$0Mar 8, 1991--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 III
Other15$0$0Jan 6, 1991--
Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $0
1910.303Electrical - General Requirements4 citations · $0
1910.219Mechanical Power-Transmission Apparatus2 citations · $0

Industry comparison

BLS 2024 survey: elementary and secondary schools reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 4.7%; NAICS 6111 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in MEXICO, NY