MISSISSIPPI POLYMERS
2733 SOUTH HARPER ROAD, CORINTH, MS 38834 · NAICS 326199 All Other Plastics Product Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 3, 2024#347459042May 3, 2024Referral (C) · Partial scope, Safety#347459042$19,0413 viol.3 violations$19,041 in penalties
Inspection #347459042
Dates
- Opened
- May 3, 2024
- Closing Conference Date
- May 3, 2024
- Final Order
- Aug 6, 2024
- Closed
- Oct 9, 2024
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 106
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $31,734
- Penalties on Record
- $19,041
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326113 Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C05 I | Serious | 1 | 2 | $10,578 | $6,347 | - | Aug 6, 2024 | |
| 01002 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 D04 I | Serious | 1 | 2 | $10,578 | $6,347 | - | Aug 6, 2024 | |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 2 | $10,578 | $6,347 | - | Aug 6, 2024 |
Aug 3, 2016#341672103Aug 3, 2016Referral (C) · Partial scope, Safety#341672103$12,6983 viol.3 violations$12,698 in penalties
Inspection #341672103
Dates
- Opened
- Aug 3, 2016
- Closing Conference Date
- Aug 3, 2016
- Final Order
- Oct 17, 2016
- Closed
- Oct 24, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 160
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $21,164
- Penalties on Record
- $12,698
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326199 All Other Plastics Product Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 4 | $10,582 | $6,349 | Oct 26, 2016 | - | Oct 17, 2016 |
| 01001B | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I A | Serious | 1 | 4 | $0 | $0 | Oct 26, 2016 | - | Oct 17, 2016 |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 4 | $10,582 | $6,349 | - | Oct 17, 2016 |
Feb 2, 2016#341215549Feb 2, 2016Referral (C) · Complete scope, Safety#341215549$17,93012 viol.12 violations$17,930 in penalties
Inspection #341215549
Dates
- Opened
- Feb 2, 2016
- Closing Conference Date
- Feb 4, 2016
- Final Order
- May 17, 2016
- Closed
- Oct 12, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 160
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 9 serious, 3 other-than-serious
- Initial Penalties
- $24,300
- Penalties on Record
- $17,930
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326199 All Other Plastics Product Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (7 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 OSHA citation code: 19100022 A02 | Serious | 1 | 1 | $2,700 | $1,970 | - | May 17, 2016 | |
| 01002 | 1910.136 Foot Protection OSHA citation code: 19100136 A | Serious | 4 | 4 | $3,600 | $2,620 | Aug 1, 2016 | - | May 17, 2016 |
| 01003A | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I A | Serious | 7 | 15 | $6,300 | $4,900 | Jun 7, 2016 | - | May 17, 2016 |
| 01003B | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 D03 | Serious | 7 | 15 | $0 | $0 | Jun 7, 2016 | - | May 17, 2016 |
| 01004A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 6 | $6,300 | $4,500 | Jun 7, 2016 | - | May 17, 2016 |
| 01005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 3 | 5 | $2,700 | $1,970 | May 23, 2016 | - | May 17, 2016 |
| 01005B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04 I | Serious | 3 | 6 | $0 | $0 | May 23, 2016 | - | May 17, 2016 |
Showing the 7 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 7, 2015#340979228Oct 7, 2015Referral (C) · Partial scope, Safety#340979228$18,0557 viol.7 violations$18,055 in penalties
Inspection #340979228
Dates
- Opened
- Oct 7, 2015
- Closing Conference Date
- Oct 9, 2015
- Final Order
- Feb 2, 2016
- Closed
- Jun 15, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 160
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 7 serious
- Initial Penalties
- $28,080
- Penalties on Record
- $18,055
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326113 Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 C01 | Serious | 1 | 2 | $3,825 | $2,500 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01002 | 1910.24 OSHA citation code: 19100024 H | Serious | 1 | 2 | $2,295 | $1,500 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01003 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I A | Serious | 1 | 4 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01004 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 D03 | Serious | 1 | 3 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 2 | 3 | $3,060 | $1,950 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01005B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04 II | Serious | 1 | 3 | $0 | $0 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01006 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F01 I | Serious | 1 | 2 | $6,300 | $4,035 | - | Feb 2, 2016 |
Oct 1, 2015#340958495Oct 1, 2015Referral (C) · Partial scope, Safety#340958495$18,0906 viol.6 violations$18,090 in penalties
Inspection #340958495
Dates
- Opened
- Oct 1, 2015
- Closing Conference Date
- Oct 1, 2015
- Final Order
- Feb 2, 2016
- Closed
- Apr 4, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 160
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $28,260
- Penalties on Record
- $18,090
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326113 Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 OSHA citation code: 19100022 C | Serious | 1 | 3 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01002 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I A | Serious | 1 | 4 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01003 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 D03 | Serious | 1 | 4 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 3 | $6,300 | $4,035 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04 I | Serious | 2 | 2 | $3,060 | $1,950 | Feb 5, 2016 | - | Feb 2, 2016 |
| 01005B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04 II | Serious | 1 | 2 | $0 | $0 | Feb 5, 2016 | - | Feb 2, 2016 |
Apr 4, 2012#333870822Apr 4, 2012Planned (H) · Complete scope, Health#333870822$1,0332 viol.2 violations$1,033 in penalties
Inspection #333870822
Dates
- Opened
- Apr 4, 2012
- Closing Conference Date
- Apr 5, 2012
- Final Order
- Jun 15, 2012
- Closed
- Jun 15, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $1,721
- Penalties on Record
- $1,033
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326199 All Other Plastics Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 I | Serious | 1 | 2 | $1,721 | $1,033 | - | Jun 15, 2012 | |
| 02001 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 III | Other | 1 | 1 | $0 | $0 | - | Jun 15, 2012 |
Jul 27, 2006#308771575Jul 27, 2006Complaint (B) · Partial scope, Health#308771575$3,7509 viol.9 violations$3,750 in penalties
Inspection #308771575
Dates
- Opened
- Jul 27, 2006
- Closing Conference Date
- Sep 25, 2006
- Closed
- Dec 5, 2006
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 270
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 9 serious
- Initial Penalties
- $3,750
- Penalties on Record
- $3,750
- Site Address
- 2733 South Harper Road, Corinth, MS 38834
- Industry
- 326199 All Other Plastics Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (7 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D02 | Serious | 1 | 2 | $1,875 | $1,875 | Nov 24, 2006 | - | - |
| 01001B | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D03 | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
| 01001C | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D04 I | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
| 01001D | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D06 | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
| 01001E | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D08 | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
| 01001F | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D09 | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
| 01001G | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 D10 | Serious | 1 | 2 | $0 | $0 | Nov 24, 2006 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
7 inspections, 2006 to 2024. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Industry comparison
Plastics and Rubber Products Manufacturing, 12,561 employers with OSHA inspections. Arithmetic from DOL records.