Skip to content
SafetyRecord logoSafetyRecord
MUHLENBERG READY MIX CO INC
$1,190
penalties
23
viol.
5
insp.

MUHLENBERG READY MIX CO INC

FRONT STREET, Central City, KY 42330

Inspections
5
Nov 1982 to Feb 1996 · 5 safety, 0 health
Violations
23
across 5 inspections
Penalties on record
$1,190
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 19

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 7, 1996Planned (H) · Complete scope, Safety#124603549$7504 viol.

Inspection #124603549

Dates

Opened
Feb 7, 1996
Closing Conference Date
Feb 7, 1996
Closed
Apr 5, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$750
Penalties on Record
$750
Site Address
Front Street, Central City, KY 42330
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious11$750$750Apr 17, 1996--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other11$0$0Apr 17, 1996--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other11$0$0Apr 17, 1996--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other11$0$0Apr 17, 1996--
Jan 13, 1988Planned (H) · Complete scope, Safety#2800225$4407 viol.

Inspection #2800225

Dates

Opened
Jan 13, 1988
Closing Conference Date
Jan 13, 1988
Contested
Apr 5, 1988
Closed
Jan 23, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$440
Penalties on Record
$440
Site Address
Front Street, Central City, KY 42330
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Apr 5, 1988. Final orders are recorded through May 2, 1988. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$160$160Mar 4, 1988Apr 5, 1988May 2, 1988
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Mar 4, 1988--
010021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious11$280$280Feb 29, 1988Apr 5, 1988May 2, 1988
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$0$0Feb 29, 1988--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other16$0$0Apr 1, 1988--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other16$0$0Apr 1, 1988--
020041910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other16$0$0Apr 1, 1988--
Feb 15, 1985Planned (H) · Complete scope, Safety#14779722$02 viol.

Inspection #14779722

Dates

Opened
Feb 15, 1985
Closing Conference Date
Feb 15, 1985
Closed
May 7, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Front Street, Central City, KY 42330
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 G03 III
Other15$0$0May 6, 1985--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$0$0May 6, 1985--
Feb 7, 1983Follow-Up (F) · Partial scope, Safety#13924808$00 viol.

Inspection #13924808

Dates

Opened
Feb 7, 1983
Closing Conference Date
Feb 7, 1983
Closed
Mar 8, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Front St, Central City, KY 42330
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 1, 1982Planned (H) · Complete scope, Safety#13924188$010 viol.

Inspection #13924188

Dates

Opened
Nov 1, 1982
Closing Conference Date
Nov 1, 1982
Closed
Mar 8, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
10
Violation Types
10 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Front St, Central City, KY 42330
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 G08
Other3-$0$0Jan 24, 1983--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other1-$0$0Feb 14, 1983--
010031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other2-$0$0Feb 14, 1983--
010041910.303
OSHA citation code: 19100303 F
Other1-$0$0Jan 18, 1983--
010051910.304
Wiring design and protection
OSHA citation code: 19100304 A02
Other5-$0$0Jan 31, 1983--
010061910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other5-$0$0Jan 31, 1983--
010071910.304
Wiring design and protection
OSHA citation code: 19100304 F05 VC1
Other1-$0$0Jan 31, 1983--
010081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other2-$0$0Jan 31, 1983--
010091910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 II
Other1-$0$0Jan 31, 1983--
010101910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Other1-$0$0Jan 31, 1983--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $0
1910.304Wiring design and protection4 citations · $280
1910.305Wiring methods, components, and equipment for general use3 citations · $0

Other inspected employers in Central City, KY

All employers in Central City →