Skip to content
SafetyRecord logoSafetyRecord
NEPTUNE DEPARTMENT OF PUBLIC WORKS
$67,000
penalties
38
viol.
4
insp.

NEPTUNE DEPARTMENT OF PUBLIC WORKS

41 TFH WAY, Neptune, NJ 07753NAICS 561210 Facilities Support Services

Inspections
4
Apr 2003 to Feb 2021 · 3 safety, 1 health
Violations
38
across 4 inspections
Penalties on record
$67,000
latest amounts in DOL records
By classification
Serious 23Willful 0Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 4, 2021Complaint (B) · Partial scope, Health#345136113$00 viol.

Inspection #345136113

Dates

Opened
Feb 4, 2021
Closing Conference Date
Feb 4, 2021
Closed
Sep 1, 2021

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2201 Heck Ave., Neptune, NJ 07753
Industry
561210 Facilities Support Services

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Aug 3, 2016Follow-Up (F) · Partial scope, Safety#341668994$00 viol.

Inspection #341668994

Dates

Opened
Aug 3, 2016
Closing Conference Date
Aug 3, 2016
Closed
Aug 3, 2016

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
51

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2201 Heck Ave., Neptune, NJ 07753
Industry
561210 Facilities Support Services

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 1, 2016Planned (H) · Complete scope, Safety#341518868$67,00027 viol.

Inspection #341518868

Dates

Opened
Jun 1, 2016
Closing Conference Date
Jun 1, 2016
Final Order
Aug 3, 2016
Closed
Aug 3, 2016

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
51

Violations and Penalties

Total Violations
27
Violation Types
12 serious, 15 other-than-serious
Initial Penalties
$67,000
Penalties on Record
$67,000
Site Address
2201 Heck Ave., Neptune, NJ 07753
Industry
561210 Facilities Support Services

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 27 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 D01
Serious551$4,000$4,000Aug 3, 2016-Aug 3, 2016
010021910.24
OSHA citation code: 19100024 F
Serious151$4,000$4,000Jul 6, 2016-Aug 3, 2016
010031910.26
OSHA citation code: 19100026 C02 VII
Serious151$4,000$4,000Jun 28, 2016-Aug 3, 2016
010041910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious951$4,000$4,000Aug 1, 2016-Aug 3, 2016
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious151$4,000$4,000Jul 1, 2016-Aug 3, 2016
010061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious251$4,000$4,000Jun 24, 2016-Aug 3, 2016
010071910.303
OSHA citation code: 19100303 G01 I
Serious251$4,000$4,000Jul 1, 2016-Aug 3, 2016
010081910.303
OSHA citation code: 19100303 G02 II
Serious551$4,000$4,000Jul 1, 2016-Aug 3, 2016
010091910.304
Wiring design and protection
OSHA citation code: 19100304 G05
Serious151$5,000$5,000-Aug 3, 2016
010101910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 IV
Serious151$5,000$5,000Jul 1, 2016-Aug 3, 2016
010111910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious251$5,000$5,000-Aug 3, 2016
01012N.J.S.A.
OSHA citation code: N.J.S.A. 34:6A-33(A)
Serious251$5,000$5,000Aug 3, 2016-Aug 3, 2016

Showing the 12 violations listed first by citation identifier. This inspection has 27 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 10, 2003Planned (H) · Complete scope, Safety#306244583$011 viol.

Inspection #306244583

Dates

Opened
Apr 10, 2003
Closing Conference Date
Apr 10, 2003
Closed
Jul 28, 2003

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
11
Violation Types
11 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
41 Tfh Way, Neptune, NJ 07753
Industry
561210 Facilities Support Services

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
OSHA citation code: 19100036 D01
Serious415$0$0May 1, 2003--
010021910.106
OSHA citation code: 19100106 G07
Serious115$0$0Jun 30, 2003--
010031910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious115$0$0May 1, 2003--
010041910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious215$0$0Jun 30, 2003--
010051910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M12
Serious115$0$0Jun 30, 2003--
010061910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious115$0$0Jun 30, 2003--
010071910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious115$0$0May 1, 2003--
010081910.303
OSHA citation code: 19100303 B01 I
Serious315$0$0May 1, 2003--
010091910.303
OSHA citation code: 19100303 B01 III
Serious215$0$0May 1, 2003--
010101910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 I
Serious315$0$0Jun 30, 2003--
010111910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious115$0$0Jun 30, 2003--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.3034 citations · $8,000
1910.146Permit-Required Confined Spaces3 citations · $3,000
1910.305Wiring methods, components, and equipment for general use3 citations · $5,000

Industry comparison

Violations per inspection
This employer9.5
Industry average1.6
Penalties per inspection
This employer$16,750
Industry average$1,886

Administrative and Support Services, 52,419 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: facilities support services reported 2.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.4%; NAICS 5612 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Neptune, NJ

All employers in Neptune →