Skip to content
SafetyRecord logoSafetyRecord
NEWCOURT INC
$7,025
penalties
24
viol.
6
insp.

NEWCOURT INC

150 EARLAND DRIVE, New Holland, PA 17557NAICS 332321 Metal Window and Door Manufacturing

Inspections
6
Jul 1978 to Apr 2003 · 5 safety, 1 health
Violations
24
across 6 inspections
Penalties on record
$7,025
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 30, 2003Planned (H) · Partial scope, Safety#112669932$4,2008 viol.

Inspection #112669932

Dates

Opened
Apr 30, 2003
Closing Conference Date
Apr 30, 2003
Closed
Jul 9, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$4,200
Site Address
150 Earland Drive, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$600$600Jul 14, 2003--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$800$800Jul 14, 2003--
010031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious11$800$800Jul 14, 2003--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$800$800Jul 14, 2003--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Jul 14, 2003--
010051910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious11$600$600Jul 14, 2003--
010061910.303
OSHA citation code: 19100303 B02
Serious11$600$600Jul 14, 2003--
020011910.303
OSHA citation code: 19100303 G01 I
Other11$0$0Jul 14, 2003--
Apr 8, 1998Planned (H) · No Inspection scope, Safety#116195173$00 viol.

Inspection #116195173

Dates

Opened
Apr 8, 1998
Closing Conference Date
Apr 8, 1998
Closed
Apr 13, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
18

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
150 Earland Drive, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 21, 1994Planned (H) · No Inspection scope, Safety#123182057$1,9255 viol.

Inspection #123182057

Dates

Opened
Sep 21, 1994
Closing Conference Date
Oct 27, 1994
Closed
Dec 31, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,925
Penalties on Record
$1,925
Site Address
150 Earland Drive, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Serious11$1,225$1,225Jan 8, 1995--
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$700$700Jan 8, 1995--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$0$0Jan 8, 1995--
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other11$0$0Jan 8, 1995--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other120$0$0Jan 8, 1995--
Nov 14, 1983Planned (H) · Complete scope, Safety#12523650$00 viol.

Inspection #12523650

Dates

Opened
Nov 14, 1983
Closing Conference Date
Nov 14, 1983
Closed
Nov 28, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
150 Earland Dr, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 3, 1978Complaint (B) · Complete scope, Health#12529400$00 viol.

Inspection #12529400

Dates

Opened
Aug 3, 1978
Closing Conference Date
Jul 6, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Yes
Owner Type
Not recorded
Union Status
No
Number of Employees
29
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
150 Earland Drive, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jul 11, 1978Complaint (B) · Complete scope, Safety#12532966$90011 viol.

Inspection #12532966

Dates

Opened
Jul 11, 1978
Closing Conference Date
Aug 4, 1978
Contested
Sep 15, 1978
Closed
Apr 10, 1979

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
18
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
5 serious, 6 other-than-serious
Initial Penalties
$900
Penalties on Record
$900
Site Address
150 Earland Drive, New Holland, PA 17557
Industry
332321 Metal Window and Door Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious1-$240$240Sep 23, 1978Sep 15, 1978-
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious1-$240$240Sep 8, 1978Sep 15, 1978-
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious1-$240$240Sep 23, 1978Sep 15, 1978-
01004A1910.309
OSHA citation code: 19100309 A 011017
Serious1-$180$180Aug 31, 1978Sep 15, 1978-
01004B1910.309
OSHA citation code: 19100309 A 025045
Serious1-$0$0Aug 31, 1978Sep 15, 1978-
020011910.23
OSHA citation code: 19100023 C01
Other2-$0$0Sep 8, 1978--
020021910.132
General requirements
OSHA citation code: 19100132 A
Other1-$0$0Sep 23, 1978--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 A02
Other2-$0$0Aug 31, 1978--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus4 citations · $1,500
1910.212General Requirements for All Machines (Machine Guarding)4 citations · $1,640
1910.3094 citations · $180

Industry comparison

Violations per inspection
This employer4.0
Industry average3.3
Penalties per inspection
This employer$1,171
Industry average$2,302

Fabricated Metal Product Manufacturing, 45,931 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal window and door manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in New Holland, PA

All employers in New Holland →