NITTERHOUSE MASONRY PRODUCTS, LLC
$23,796
penalties
28
viol.
7
insp.

NITTERHOUSE MASONRY PRODUCTS, LLC

859 CLEVELAND AVENUE, Chambersburg, PA 17201NAICS 327390 Other Concrete Product Manufacturing

Inspections
7
Oct 1990 to Aug 2024 · 6 safety, 1 health
Violations
28
across 7 inspections
Penalties on record
$23,796
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 23, 2024Follow-Up (F) · Partial scope, Safety#347708810$8,0003 viol.

Inspection #347708810

Dates

Opened
Aug 23, 2024
Closing Conference Date
Aug 23, 2024
Final Order
Dec 18, 2024
Closed
Mar 20, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$4,839
Penalties on Record
$8,000
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327390 Other Concrete Product Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1910.28
OSHA citation code: 19100028 B01 I
Other11$0$4,000Dec 19, 2024-Dec 18, 2024
01002A1910.303
OSHA citation code: 19100303 B08 I
Other11$4,839$4,000-Dec 18, 2024
01002B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02 I
Other11$0$0-Dec 18, 2024
Jun 28, 2023Planned (H) · Partial scope, Health#346801251$00 viol.

Inspection #346801251

Dates

Opened
Jun 28, 2023
Closing Conference Date
Jun 28, 2023
Closed
Dec 18, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327390 Other Concrete Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 28, 2023Referral (C) · Partial scope, Safety#346798580$8,9687 viol.

Inspection #346798580

Dates

Opened
Jun 28, 2023
Closing Conference Date
Jun 28, 2023
Contested
Dec 7, 2023
Final Order
Mar 12, 2024
Closed
Apr 15, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 3 other-than-serious
Initial Penalties
$18,749
Penalties on Record
$8,968
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327390 Other Concrete Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious15$6,250$3,500Dec 18, 2023Dec 7, 2023Mar 12, 2024
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious15$0$0Dec 18, 2023Dec 7, 2023Mar 12, 2024
010021910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 A
Serious14$4,687$2,343Dec 18, 2023Dec 7, 2023Mar 12, 2024
010031910.303
OSHA citation code: 19100303 G02 I
Serious15$6,250$3,125Dec 14, 2023Dec 7, 2023Mar 12, 2024
020011904.32
Annual Summary
OSHA citation code: 19040032 B03
Other150$1,562$0Dec 18, 2023Dec 7, 2023Mar 12, 2024
020021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C05 II D
Other15$0$0Dec 18, 2023Dec 7, 2023Mar 12, 2024
020031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A04
Other122$0$0Dec 7, 2023Mar 12, 2024
May 28, 2010Planned (H) · Records Only scope, Safety#314239690$00 viol.

Inspection #314239690

Dates

Opened
May 28, 2010
Closing Conference Date
May 28, 2010
Closed
Jun 2, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
39

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 27, 2004Planned (H) · Complete scope, Safety#305842171$6,00016 viol.

Inspection #305842171

Dates

Opened
Jul 27, 2004
Closing Conference Date
Jul 27, 2004
Closed
Sep 8, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
54

Violations and Penalties

Total Violations
16
Violation Types
16 serious
Initial Penalties
$11,925
Penalties on Record
$6,000
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious24$1,125$700Sep 13, 2004--
010021910.36
OSHA citation code: 19100036 D01
Serious13$675$400Aug 20, 2004--
010031910.145
Specifications for Accident Prevention Signs and Tags
OSHA citation code: 19100145 C03
Serious11$675$0Sep 13, 2004--
010041910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$900$500Sep 13, 2004--
010051910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A06
Serious12$675$0Sep 13, 2004--
010061910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious11$675$400Sep 13, 2004--
010071910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious12$675$400Sep 13, 2004--

Showing the 7 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 12, 2002Planned (H) · Complete scope, Safety#300416070$8282 viol.

Inspection #300416070

Dates

Opened
Mar 12, 2002
Closing Conference Date
Mar 20, 2002
Closed
Apr 30, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
40

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,275
Penalties on Record
$828
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327390 Other Concrete Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 C
Serious12$1,275$828Apr 16, 2002--
020011910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other12$0$0Mar 26, 2002--
Oct 15, 1990Planned (H) · Complete scope, Safety#102719739$00 viol.

Inspection #102719739

Dates

Opened
Oct 15, 1990
Closing Conference Date
Oct 16, 1990
Closed
Nov 6, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
859 Cleveland Avenue, Chambersburg, PA 17201
Industry
327390 Other Concrete Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.178Powered Industrial Trucks4 citations · $800
1910.219Mechanical Power-Transmission Apparatus3 citations · $1,000
1910.147The control of hazardous energy (lockout/tagout)3 citations · $3,500

Industry comparison

Violations per inspection
This employer4.0
Industry average3.3
Penalties per inspection
This employer$3,399
Industry average$2,354

Nonmetallic Mineral Product Manufacturing, 16,980 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Chambersburg, PA

All employers in Chambersburg →