Skip to content
SafetyRecord logoSafetyRecord
PAC UNITED CORP. LTD.
$35,400
penalties
13
viol.
2
insp.

PAC UNITED CORP. LTD.

2-STORY RESIDENTIAL PROJECT, DEDEDO, GU 96912

Inspections
2
Feb 1995 to Sep 1998 · 2 safety, 0 health
Violations
13
across 2 inspections
Penalties on record
$35,400
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 2Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 22, 1998Follow-Up (F) · No Inspection scope, Safety#109338947$00 viol.

Inspection #109338947

Dates

Opened
Sep 22, 1998
Closing Conference Date
Sep 22, 1998
Closed
Sep 22, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2-Story Residential Project, Dededo, GU 96912
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 9, 1995Referral (C) · Partial scope, Safety#106189335$35,40013 viol.

Inspection #106189335

Dates

Opened
Feb 9, 1995
Closing Conference Date
Feb 9, 1995
Contested
Aug 31, 1995
Final Order
Dec 13, 1995
Closed
Oct 12, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
74
Related Activity
1 referral

Violations and Penalties

Total Violations
13
Violation Types
11 serious, 2 repeat
Initial Penalties
$35,400
Penalties on Record
$35,400
Site Address
2-Story Residential Project, Dededo, GU 96912
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D03
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010051926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D07
Serious12$1,500$1,500Aug 3, 1995Aug 31, 1995Dec 13, 1995
010061926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010071926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E04
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
010081926.703
Concrete and Masonry - Cast-in-Place Concrete
OSHA citation code: 19260703 B03
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
01009A1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Serious12$3,000$3,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
01009B1926.1052
Stairways (Construction)
OSHA citation code: 19261052 C04
Serious12$0$0Aug 3, 1995Aug 31, 1995Dec 13, 1995
010101926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious12$2,100$2,100Aug 3, 1995Aug 31, 1995Dec 13, 1995
020011926.25
Housekeeping
OSHA citation code: 19260025 A
Repeat12$1,800$1,800Aug 3, 1995Aug 31, 1995Dec 13, 1995
020021926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 D01
Repeat12$6,000$6,000Aug 3, 1995Aug 31, 1995Dec 13, 1995
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements5 citations · $13,500
1926.1052Stairways (Construction)2 citations · $3,000
1926.405Electrical - Wiring Methods (Construction)1 citation · $3,000

Other inspected employers in DEDEDO, GU