PEASE & CURREN
75 PENNSYLVANIA AVE., WARWICK, RI 02888
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 16, 2026#349058487Jul 16, 2026OpenComplaint (B) · Partial scope, HealthOpen#349058487$00 viol.0 violations$0 in penalties
Inspection #349058487
Dates
- Opened
- Jul 16, 2026
- Closing Conference Date
- Jul 16, 2026
- Closed
- Open
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 75 Pennsylvania Avenue, Warwick, RI 02888
- Industry
- 331492 Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Sep 27, 2017#342666724Sep 27, 2017Planned (H) · Partial scope, Safety#342666724$2,5353 viol.3 violations$2,535 in penalties
Inspection #342666724
Dates
- Opened
- Sep 27, 2017
- Closing Conference Date
- Sep 27, 2017
- Final Order
- Oct 20, 2017
- Closed
- Oct 25, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 23
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $3,622
- Penalties on Record
- $2,535
- Site Address
- 75 Pennsylvania Avenue, Warwick, RI 02888
- Industry
- 331492 Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Serious | 1 | 1 | $3,622 | $2,535 | Nov 27, 2017 | - | Oct 20, 2017 |
| 01001B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $0 | $0 | Nov 27, 2017 | - | Oct 20, 2017 |
| 01001C | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 2 | 3 | $0 | $0 | Nov 27, 2017 | - | Oct 20, 2017 |
Jan 6, 2010#312344427Jan 6, 2010Planned (H) · No Inspection scope, Health#312344427$00 viol.0 violations$0 in penalties
Inspection #312344427
Dates
- Opened
- Jan 6, 2010
- Closing Conference Date
- Not recorded
- Closed
- Jan 7, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- 331492 Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jun 21, 2002#304988371Jun 21, 2002Planned (H) · Partial scope, Health#304988371$8767 viol.7 violations$876 in penalties
Inspection #304988371
Dates
- Opened
- Jun 21, 2002
- Closing Conference Date
- Aug 22, 2002
- Closed
- Nov 5, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 39
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 4 serious, 3 other-than-serious
- Initial Penalties
- $1,750
- Penalties on Record
- $876
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 7 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 7 | 0 - 0.0003375 | mg/m³ |
| Cadmium | 7 | 0 - 0.0014337 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 7 | 0 - 0.0338646 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 | mg/m³ |
| Copper Fume (as Cu) | 7 | 0 - 0.3431872 | mg/m³ |
| Iron Oxide Fume | 7 | 0 - 0.9476161 | mg/m³ |
| Lead, Inorganic (as Pb) | 7 | 0 - 0.0600729 | mg/m³ |
| Manganese Fume (as Mn) | 7 | 0 - 0.0184024 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 7 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 7 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 7 | 0 | mg/m³ |
| Zinc Oxide Fume | 7 | 0 - 0.1338223 | mg/m³ |
Violations
Violation list (5 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.24 Step Bolts and Manhole Steps OSHA citation code: 19100024 B | Serious | 1 | 1 | $525 | $263 | Sep 30, 2002 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 2 | $525 | $263 | Sep 30, 2002 | - | - |
| 01003A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 2 | $700 | $350 | Sep 30, 2002 | - | - |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 1 | $0 | $0 | Sep 27, 2002 | - | - |
| 02001 | 1910.1025 Lead OSHA citation code: 19101025 D06 II | Other | 2 | 2 | $0 | $0 | Nov 12, 2002 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jul 14, 1994#122514839Jul 14, 1994Planned (H) · Complete scope, Health#122514839$1,3145 viol.5 violations$1,314 in penalties
Inspection #122514839
Dates
- Opened
- Jul 14, 1994
- Closing Conference Date
- Nov 2, 1994
- Closed
- Jun 30, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 42
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $2,625
- Penalties on Record
- $1,314
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling8 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 6 | 0 | mg/m³ |
| Cadmium | 6 | 0 - 0.0033 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 - 0.1958 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 - 0.0119 | mg/m³ |
| Silver, Metal and Soluble Compounds (as Ag) | 6 | 0 - 0.1836 | mg/m³ |
| Tin, inorganic compounds (except oxides) (as Sn) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 - 0.0916 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | 1 | $875 | $438 | Nov 10, 1994 | - | - |
| 01002 | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 2 | 3 | $875 | $438 | Jul 1, 1995 | - | - |
| 01003 | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 2 | 3 | $875 | $438 | Jul 1, 1995 | - | - |
| 02001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G06 | Other | 1 | 1 | $0 | $0 | Dec 22, 1994 | - | - |
| 02002 | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 C01 I | Other | 1 | 1 | $0 | $0 | Dec 22, 1994 | - | - |
Dec 28, 1988#100775287Dec 28, 1988Monitoring (D) · Partial scope, Health#100775287$00 viol.0 violations$0 in penalties
Inspection #100775287
Dates
- Opened
- Dec 28, 1988
- Closing Conference Date
- Jan 3, 1989
- Closed
- Feb 15, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 17 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 16 | 0 - 0.0009 | mg/m³ |
| Cadmium Fume (as Cd) | 17 | 0 - 0.0134 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 17 | 0 - 0.0121 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 17 | 0 - 0.0124 | mg/m³ |
| Copper Fume (as Cu) | 17 | 0 - 0.8429 | mg/m³ |
| Iron Oxide Fume | 17 | 0 - 10.0523 | mg/m³ |
| Lead, Inorganic (as Pb) | 17 | 0 - 0.32 | mg/m³ |
| Manganese Fume (as Mn) | 17 | 0 - 0.2879 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 17 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 17 | 0 - 0.0482 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 16 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 17 | 0 | mg/m³ |
| Zinc Oxide Fume | 17 | 0 - 0.3138 | mg/m³ |
Dec 18, 1987#18263970Dec 18, 1987Monitoring (D) · Partial scope, Health#18263970$2,3526 viol.6 violations$2,352 in penalties
Inspection #18263970
Dates
- Opened
- Dec 18, 1987
- Closing Conference Date
- Feb 5, 1988
- Closed
- Apr 20, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 2 repeat, 4 other-than-serious
- Initial Penalties
- $3,360
- Penalties on Record
- $2,352
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (5 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B03 | Repeat | 1 | 2 | $1,680 | $1,176 | Feb 23, 1988 | - | - |
| 01002 | 1910.1025 Lead OSHA citation code: 19101025 J01 I | Repeat | 2 | 2 | $1,680 | $1,176 | Feb 23, 1988 | - | - |
| 02001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B09 | Other | 2 | 4 | $0 | $0 | Mar 7, 1988 | - | - |
| 02002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 I | Other | 1 | 1 | $0 | $0 | Feb 23, 1988 | - | - |
| 02003 | 1910.141 Sanitation OSHA citation code: 19100141 A04 II | Other | 1 | 40 | $0 | $0 | Feb 23, 1988 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 14, 1986#101401560Nov 14, 1986Monitoring (D) · Partial scope, Health#101401560$2,13531 viol.31 violations$2,135 in penalties
Inspection #101401560
Dates
- Opened
- Nov 14, 1986
- Closing Conference Date
- Mar 19, 1987
- Closed
- Mar 2, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 31
- Violation Types
- 9 serious, 19 repeat, 3 other-than-serious
- Initial Penalties
- $3,050
- Penalties on Record
- $2,135
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling16 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3225P / 7A | 0 - 0.0218 | mg/m³ |
| Arsenic, Inorganic | 3 | 0 - 0.0006 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3124P / 7A | 0 - 0.0006 | mg/m³ |
| Cadmium Fume (as Cd) | 3225P / 7A | 0 - 0.4928 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3225P / 7A | 0 - 0.0354 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3225P / 7A | 0 - 0.0232 | mg/m³ |
| Copper Fume (as Cu) | 3225P / 7A | 0 - 2.1979 | mg/m³ |
| Iron Oxide Fume | 3225P / 7A | 0 - 2.766 | mg/m³ |
| Lead, Inorganic (as Pb) | 3225P / 7A | 0 - 0.5015 | mg/m³ |
| Manganese Fume (as Mn) | 3225P / 7A | 0 - 0.0592 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3225P / 7A | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3225P / 7A | 0 - 0.2579 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 4736P / 11A | 0 | mg/m³ |
| Silver, Metal and Soluble Compounds (as Ag) | 11 | 0 - 0.73 | mg/m³ |
| Vanadium fume (as V2O5) | 3225P / 7A | 0 - 0.0047 | mg/m³ |
| Zinc Oxide Fume | 3225P / 7A | 0 - 1.2573 | mg/m³ |
Violations
Violation list (5 of 31 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1025 Lead OSHA citation code: 19101025 I04 III | Serious | 3 | 3 | $250 | $175 | Apr 17, 1987 | - | - |
| 01001B | 1910.1025 Lead OSHA citation code: 19101025 I04 IV | Serious | 1 | 1 | $0 | $0 | Apr 17, 1987 | - | - |
| 01002A | 1910.1200 Hazard Communication OSHA citation code: 19101200 D06 | Serious | 1 | 40 | $300 | $210 | May 15, 1987 | - | - |
| 01002B | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 40 | $0 | $0 | May 15, 1987 | - | - |
| 01002C | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 II | Serious | 100 | 40 | $0 | $0 | May 15, 1987 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 31 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 14, 1985#930693May 14, 1985Planned (H) · Complete scope, Health#930693$1,50059 viol.59 violations$1,500 in penalties
Inspection #930693
Dates
- Opened
- May 14, 1985
- Closing Conference Date
- Nov 18, 1985
- Closed
- Feb 16, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 59
- Violation Types
- 32 serious, 27 other-than-serious
- Initial Penalties
- $3,000
- Penalties on Record
- $1,500
- Site Address
- 75 Pennsylvania Ave., Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling17 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 9 | 0 - 0.0708 | mg/m³ |
| Arsenic, Inorganic | 1 | 0.049 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 9 | 0 - 0.007 | mg/m³ |
| Cadmium Fume (as Cd) | 9 | 0.0044 - 0.458 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 9 | 0 - 0.0522 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 9 | 0 - 0.0113 | mg/m³ |
| Copper Fume (as Cu) | 9 | 0.0048 - 2.8027 | mg/m³ |
| Iron Oxide Fume | 9 | 0.0085 - 7.3366 | mg/m³ |
| Lead, Inorganic (as Pb) | 9 | 0 - 0.2537 | mg/m³ |
| Manganese Fume (as Mn) | 9 | 0 - 0.1712 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 9 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 9 | 0 - 0.2942 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 22 | 0 | mg/m³ |
| Platinum (as Pt), soluble salts | 3 | 0 - 0.0025 | mg/m³ |
| Silver, Metal and Soluble Compounds (as Ag) | 8 | 0.0063 - 1.3 | mg/m³ |
| Vanadium fume (as V2O5) | 9 | 0 | mg/m³ |
| Zinc Oxide Fume | 9 | 0.0163 - 1.3539 | mg/m³ |
Violations
Violation list (5 of 59 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 B01 | Serious | 1 | 3 | $400 | $200 | Feb 18, 1986 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 B08 | Serious | 1 | 3 | $0 | $0 | Dec 26, 1985 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 B10 | Serious | 1 | 3 | $0 | $0 | Feb 18, 1986 | - | - |
| 01001D | 1910.134 Respiratory Protection OSHA citation code: 19100134 C | Serious | 1 | 3 | $0 | $0 | Feb 18, 1986 | - | - |
| 01001E | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 | Serious | 1 | 3 | $0 | $0 | Feb 18, 1986 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 59 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 28, 1982#10275766May 28, 1982Planned (H) · Complete scope, Safety#10275766$42025 viol.25 violations$420 in penalties
Inspection #10275766
Dates
- Opened
- May 28, 1982
- Closing Conference Date
- Jun 22, 1982
- Closed
- Aug 11, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 25
- Violation Types
- 3 serious, 22 other-than-serious
- Initial Penalties
- $420
- Penalties on Record
- $420
- Site Address
- 75 Pennsylvania Ave, Warwick, RI 02888
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 25 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A04 | Serious | 6 | - | $300 | $300 | Oct 18, 1982 | - | - |
| 01001B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | - | $0 | $0 | May 30, 1983 | - | - |
| 01001C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F01 | Serious | 1 | - | $0 | $0 | May 30, 1983 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Other | 1 | - | $0 | $0 | Oct 18, 1982 | - | - |
| 02002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Other | 2 | - | $0 | $0 | Jul 26, 1982 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 25 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
10 inspections, 1982 to 2026. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
BLS 2024 survey: secondary smelting, refining, and alloying of nonferrous metal (except copper and aluminum) reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 14.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source