PEERLESS PRODUCTS, INC.
2403 S. MAIN, FT. SCOTT, KS 66701
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 4, 2001#303795280Jan 4, 2001Planned (H) · Complete scope, Health#303795280$3,1886 viol.6 violations$3,188 in penalties
Inspection #303795280
Dates
- Opened
- Jan 4, 2001
- Closing Conference Date
- Jan 19, 2001
- Closed
- Feb 22, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 264
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $6,375
- Penalties on Record
- $3,188
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 I08 | Serious | 1 | 18 | $1,700 | $850 | Feb 21, 2001 | - | - |
| 01002 | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 H04 | Serious | 1 | 4 | $1,700 | $850 | Feb 21, 2001 | - | - |
| 01003 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 4 | $1,275 | $638 | Feb 21, 2001 | - | - |
| 01004 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 2 | 5 | $1,700 | $850 | Feb 21, 2001 | - | - |
| 02001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G06 | Other | 1 | 45 | $0 | $0 | Feb 21, 2001 | - | - |
| 02002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G07 | Other | 1 | 18 | $0 | $0 | Feb 21, 2001 | - | - |
Jan 4, 2001#303795272Jan 4, 2001Planned (H) · Complete scope, Safety#303795272$2,3397 viol.7 violations$2,339 in penalties
Inspection #303795272
Dates
- Opened
- Jan 4, 2001
- Closing Conference Date
- Jan 19, 2001
- Closed
- Feb 22, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 264
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 5 serious, 2 other-than-serious
- Initial Penalties
- $4,675
- Penalties on Record
- $2,339
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C03 | Serious | 1 | 18 | $2,125 | $1,063 | Feb 21, 2001 | - | - |
| 01002A | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Serious | 1 | 18 | $1,275 | $638 | Jan 24, 2001 | - | - |
| 01002B | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 II | Serious | 1 | 18 | $0 | $0 | Jan 24, 2001 | - | - |
| 01003A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 26 | $1,275 | $638 | Jan 24, 2001 | - | - |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 6 | $0 | $0 | Jan 24, 2001 | - | - |
| 02001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L | Other | 1 | 26 | $0 | $0 | Feb 21, 2001 | - | - |
| 02002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 I | Other | 1 | 22 | $0 | $0 | Jan 24, 2001 | - | - |
Sep 14, 1998#301014445Sep 14, 1998Planned (H) · Partial scope, Safety#301014445$4,69612 viol.12 violations$4,696 in penalties
Inspection #301014445
Dates
- Opened
- Sep 14, 1998
- Closing Conference Date
- Sep 16, 1998
- Closed
- Feb 2, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 245
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 9 serious, 3 other-than-serious
- Initial Penalties
- $9,350
- Penalties on Record
- $4,696
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 I | Serious | 41 | 77 | $1,700 | $850 | Jun 30, 1999 | - | - |
| 01001B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 II | Serious | 33 | 77 | $0 | $0 | Mar 18, 1999 | - | - |
| 01002A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 II | Serious | 261 | 77 | $1,700 | $850 | Jan 31, 2000 | - | - |
| 01002B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 III | Serious | 261 | 77 | $0 | $0 | Jan 31, 2000 | - | - |
| 01003A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 261 | 77 | $2,975 | $1,488 | Jan 31, 2000 | - | - |
| 01003B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 ID | Serious | 1 | 7 | $0 | $0 | Jun 30, 1999 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D09 IV | Serious | 261 | 77 | $1,700 | $850 | Jan 31, 2000 | - | - |
| 01005A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B01 | Serious | 3 | 17 | $1,275 | $658 | Mar 18, 1999 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 10, 1995#106590888Jan 10, 1995Complaint (B) · Partial scope, Health#106590888$9752 viol.2 violations$975 in penalties
Inspection #106590888
Dates
- Opened
- Jan 10, 1995
- Closing Conference Date
- Jan 11, 1995
- Closed
- Feb 9, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 300
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $975
- Penalties on Record
- $975
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 150 | $975 | $975 | Feb 28, 1995 | - | - |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 II | Other | 1 | 20 | $0 | $0 | Feb 28, 1995 | - | - |
Jul 10, 1987#106029697Jul 10, 1987Referral (C) · Partial scope, Safety#106029697$00 viol.0 violations$0 in penalties
Inspection #106029697
Dates
- Opened
- Jul 10, 1987
- Closing Conference Date
- Jul 20, 1987
- Closed
- Jul 10, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 330
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Apr 2, 1987#103119616Apr 2, 1987Planned (H) · Complete scope, Safety#103119616$2405 viol.5 violations$240 in penalties
Inspection #103119616
Dates
- Opened
- Apr 2, 1987
- Closing Conference Date
- Apr 3, 1987
- Closed
- May 18, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 268
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 2 serious, 3 other-than-serious
- Initial Penalties
- $240
- Penalties on Record
- $240
- Site Address
- 2403 S. Main, Ft. Scott, KS 66701
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $240 | $240 | May 7, 1987 | - | - |
| 01001B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 5 | 8 | $0 | $0 | Jun 1, 1987 | - | - |
| 02001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B05 I | Other | 4 | 8 | $0 | $0 | Jun 1, 1987 | - | - |
| 02002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 8 | 7 | $0 | $0 | Jun 1, 1987 | - | - |
| 02003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Other | 4 | 7 | $0 | $0 | Jun 1, 1987 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1987 to 2001. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.