Skip to content
SafetyRecord logoSafetyRecord
PENN COMPRESSION MOLDING INC
$23,650
penalties
29
viol.
6
insp.

PENN COMPRESSION MOLDING INC

309 COMPONENTS DR., SMITHFIELD, NC 27577

Inspections
6
Mar 1990 to Aug 2011 · 5 safety, 1 health
Violations
29
across 6 inspections
Penalties on record
$23,650
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 5Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 24, 2011Referral (C) · Complete scope, Health#315450197$00 viol.

Inspection #315450197

Dates

Opened
Aug 24, 2011
Closing Conference Date
Sep 15, 2011
Closed
Oct 24, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
53
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
326199 All Other Plastics Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Apr 7, 2009Complaint (B) · Partial scope, Safety#312879166$00 viol.

Inspection #312879166

Dates

Opened
Apr 7, 2009
Closing Conference Date
Apr 7, 2009
Closed
Apr 23, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
326199 All Other Plastics Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

May 26, 1999Planned (H) · No Inspection scope, Safety#302643275$00 viol.

Inspection #302643275

Dates

Opened
May 26, 1999
Closing Conference Date
May 26, 1999
Closed
May 26, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 20, 1993Planned (H) · Complete scope, Safety#111113759$4,9008 viol.

Inspection #111113759

Dates

Opened
Dec 20, 1993
Closing Conference Date
Dec 20, 1993
Closed
Apr 25, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
8
Violation Types
4 serious, 4 other-than-serious
Initial Penalties
$4,900
Penalties on Record
$4,900
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious210$1,225$1,225Mar 3, 1994--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious25$1,225$1,225Mar 3, 1994--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious240$1,225$1,225Mar 3, 1994--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Serious1-$1,225$1,225Mar 3, 1994--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other140$0$0Mar 30, 1994--
020021910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 A
Other12$0$0Mar 3, 1994--
020031910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other1020$0$0Mar 3, 1994--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 I
Other140$0$0Mar 3, 1994--
Aug 15, 1991Follow-Up (F) · Partial scope, Safety#18476721$16,0006 viol.

Inspection #18476721

Dates

Opened
Aug 15, 1991
Closing Conference Date
Oct 24, 1991
Contested
Jan 30, 1992
Final Order
Jun 16, 1992
Closed
Feb 24, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
34

Violations and Penalties

Total Violations
6
Violation Types
1 serious, 5 repeat
Initial Penalties
$16,000
Penalties on Record
$16,000
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A01
Repeat212$3,520$3,520Jan 13, 1992Jan 30, 1992Jun 16, 1992
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Repeat11$3,520$3,520Jan 13, 1992Jan 30, 1992Jun 16, 1992
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Repeat212$3,520$3,520Jan 13, 1992Jan 30, 1992Jun 16, 1992
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Repeat12$3,520$3,520Jan 13, 1992Jan 30, 1992Jun 16, 1992
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Repeat12$160$160Jan 13, 1992Jan 30, 1992Jun 16, 1992
030011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious212$1,760$1,760Jan 13, 1992Jan 30, 1992Jun 16, 1992
Mar 6, 1990Planned (H) · Complete scope, Safety#18460832$2,75015 viol.

Inspection #18460832

Dates

Opened
Mar 6, 1990
Closing Conference Date
Mar 13, 1990
Closed
Jun 26, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
54

Violations and Penalties

Total Violations
15
Violation Types
8 serious, 7 other-than-serious
Initial Penalties
$2,750
Penalties on Record
$2,750
Site Address
309 Components Dr., Smithfield, NC 27577
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 A
Serious212$350$350Jun 9, 1990--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A01
Serious212$350$350Apr 30, 1990--
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious554$400$400Apr 30, 1990--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious212$350$350Jun 9, 1990--
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious13$200$200Apr 30, 1990--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Serious13$350$350Apr 30, 1990--
010071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious13$350$350Apr 30, 1990--
010081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious56$400$400Apr 30, 1990--

Showing the 8 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment10 citations · $11,675
1910.304Electrical - Wiring Design and Protection6 citations · $10,240
1910.303Electrical - General Requirements4 citations · $1,575

Other inspected employers in SMITHFIELD, NC

All employers in SMITHFIELD →