PENRECO
$19,125
Penalties
14
Violations
2
Inspections

PENRECO

4401 PARK AVENUE, DICKINSON, TX 77539

NAICS 325199: All Other Basic Organic Chemical Manufacturing - Records current through Mar 20, 2008

PENRECO has had 2 OSHA inspections since Feb 14, 2007, resulting in 14 violations and $19,125 in penalties on record.

As reported in the U.S. Department of Labor OSHA enforcement database. Having inspection records is common for businesses in regulated industries. Penalty amounts may differ from final amounts after settlement or judicial review.

14Serious
0Willful
0Repeat
0Other

Overview

  • This establishment has 2 OSHA inspections on record.
  • According to public OSHA enforcement data, this location was most recently inspected on March 20, 2008. That inspection has since been closed.
  • Out of 14 violations documented at this establishment, 14 were classified as Serious, or 100% of all citations.
  • The inspection record at this location contains no willful violation citations.
  • The OSHA record at this location does not include any repeat violation citations.
  • All inspections at this establishment have been closed.

Data sourced from the U.S. Department of Labor OSHA enforcement database. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conferences, settlements, or adjudication. Having an inspection record is common in regulated industries and does not by itself indicate unsafe conditions. This is not an official OSHA resource and does not constitute legal advice.

Industry Comparison vs. Chemical Manufacturing

Violations per Inspection
7.0Above avg
Industry avg: 2.7 (12,129 employers)
Penalties per Inspection
$9,563Above avg
Industry avg: $3,703 (12,129 employers)
Most Cited Standards5 standards

Ranked by citation count across this employer's inspections on record. Counts and penalties are exact sums from violations linked to those inspections.

StandardCitationsPenalties
1910.119Process Safety Management of Highly Hazardous Chemicals8$10,125
1910.120Hazardous Waste Operations and Emergency Response2$3,000
1910.147Control of Hazardous Energy (Lockout/Tagout)2$3,000
1910.165Employee Alarm Systems1$1,500
5A0001General Duty Clause, Section 5(a)(1)1$1,500
Enforcement Timeline2 inspections, 2007-2008
Rotate your device to landscape to view the enforcement timeline visually. The full inspection records list is below.

Each row is one OSHA inspection on record. Markers show openings, contest activity, final orders, and closures. Full record detail for each inspection is listed below.

Inspection
#310267430
Follow-Up
#310260872
Planned
200720082009201020112012201320142015201620172018201920202021202220232024202520262027NOW
Penalty on record
$0
$19,125
OpenedOn recordContest recordedFinal order recordedClosedNo close date in feed

Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).

Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.

Inspection Records2007 - 2008

Full record for each inspection on file. Includes type, scope, violations on record, and current penalty.

Other Inspected Employers in DICKINSON, TX

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.