Skip to content
SafetyRecord logoSafetyRecord
PETREX, INC.
$515
penalties
15
viol.
5
insp.

PETREX, INC.

2349 DORCON ROAD, WARREN, PA 16365NAICS 332439 Other Metal Container Manufacturing

Inspections
5
Apr 1983 to Mar 2023 · 3 safety, 2 health
Violations
15
across 5 inspections
Penalties on record
$515
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 1, 2023Complaint (B) · Partial scope, Health#346537640$00 viol.

Inspection #346537640

Dates

Opened
Mar 1, 2023
Closing Conference Date
Mar 1, 2023
Closed
Sep 1, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2349 Dorcon Road, Warren, PA 16365
Industry
332439 Other Metal Container Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Dec 22, 2016Planned (H) · Partial scope, Safety#341992998$00 viol.

Inspection #341992998

Dates

Opened
Dec 22, 2016
Closing Conference Date
Dec 22, 2016
Closed
Dec 23, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2349 Dorcon Road, Warren, PA 16365
Industry
332439 Other Metal Container Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 29, 2003Planned (H) · Partial scope, Health#122168479$4553 viol.

Inspection #122168479

Dates

Opened
Jul 29, 2003
Closing Conference Date
Jul 29, 2003
Closed
Dec 10, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
33

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$700
Penalties on Record
$455
Site Address
2349 Dorcon Road, Warren, PA 16365
Industry
332313 Plate Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious14$700$455Sep 30, 2003--
01001B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious14$0$0Sep 30, 2003--
01001C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 II
Serious14$0$0Sep 30, 2003--
Dec 28, 1998Planned (H) · Partial scope, Safety#300280104$04 viol.

Inspection #300280104

Dates

Opened
Dec 28, 1998
Closing Conference Date
Jan 4, 1999
Closed
Feb 3, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2349 Dorcon Road, Warren, PA 16365
Industry
332439 Other Metal Container Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Other11$0$0Jan 31, 1999--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Other11$0$0Jan 31, 1999--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other11$0$0Jan 31, 1999--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other22$0$0Jan 24, 1999--
Apr 15, 1983Planned (H) · Complete scope, Safety#12931523$608 viol.

Inspection #12931523

Dates

Opened
Apr 15, 1983
Closing Conference Date
Apr 15, 1983
Closed
Mar 22, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$120
Penalties on Record
$60
Site Address
2349 Crescent Park Extension, Warren, PA 16365
Industry
332439 Other Metal Container Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious1-$120$60May 13, 1983--
01001B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious1-$0$0Jun 7, 1983--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other3-$0$0May 13, 1983--
020021904.6
Determination of new cases
Other3-$0$0May 13, 1983--
020031910.23
Ladders
OSHA citation code: 19100023 C01
Other1-$0$0Jun 7, 1983--
020041910.23
Ladders
OSHA citation code: 19100023 D01 III
Other1-$0$0Jun 7, 1983--
020051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other1-$0$0Jun 7, 1983--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other1-$0$0Jun 7, 1983--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)3 citations · $0
1910.217Mechanical Power Presses3 citations · $455
1910.23Ladders2 citations · $0

Industry comparison

Violations per inspection
This employer3.0
Industry average3.3
Penalties per inspection
This employer$103
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WARREN, PA