PHILLIPS MUSHROOM FARMS
$2,598
penalties
21
viol.
4
insp.

PHILLIPS MUSHROOM FARMS

BOX 146 RD #3 KOOLIN ROAD, Kennett Square, PA 19348

Inspections
4
Nov 1975 to Jun 2002 · 3 safety, 1 health
Violations
21
across 4 inspections
Penalties on record
$2,598
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 10, 2002Planned (H) · Complete scope, Safety#305369555$1,7887 viol.

Inspection #305369555

Dates

Opened
Jun 10, 2002
Closing Conference Date
Jun 10, 2002
Closed
Aug 30, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
120

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$2,750
Penalties on Record
$1,788
Site Address
1011 Kaolin Rd., Kennett Square, PA 19348
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 G01
Serious11$1,375$900Jul 31, 2002--
01001B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious11$0$0Jul 31, 2002--
01001C1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$0$0Jul 31, 2002--
01001D1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious21$0$0Aug 10, 2002--
01002A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 D
Serious11$1,375$888Jul 26, 2002--
01002B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious21$0$0Jul 31, 2002--
01002C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious11$0$0Jul 31, 2002--
Feb 18, 1976Follow-Up (F) · Complete scope, Safety#12731543$00 viol.

Inspection #12731543

Dates

Opened
Feb 18, 1976
Closing Conference Date
Feb 18, 1976
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Box 146 Rd #3 Koolin Road, Kennett Square, PA 19348
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 6, 1976Planned (H) · Complete scope, Health#12669180$02 viol.

Inspection #12669180

Dates

Opened
Feb 6, 1976
Closing Conference Date
Feb 19, 1976
Closed
Mar 11, 1976

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Box 146 Rd3 Kaolin Road, Kennett Square, PA 19348
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.5
Determination of Work-Relatedness
Other1-$0$0Feb 27, 1976--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Other1-$0$0Mar 9, 1976--
Nov 21, 1975Planned (H) · Complete scope, Safety#12647848$81012 viol.

Inspection #12647848

Dates

Opened
Nov 21, 1975
Closing Conference Date
Nov 21, 1975
Closed
Mar 3, 1976

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
12
Violation Types
1 serious, 11 other-than-serious
Initial Penalties
$810
Penalties on Record
$810
Site Address
Box 146 Rd 3 Kaolin Road, Kennett Square, PA 19348
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 A08
Other1-$0$0Jan 12, 1976--
010021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other1-$0$0Feb 9, 1976--
010031910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Other1-$40$40Feb 9, 1976--
010041910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 I
Other1-$0$0Feb 9, 1976--
010051910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 F
Other1-$40$40Feb 9, 1976--
010061910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other2-$0$0Jan 24, 1976--
010071910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 I
Other1-$0$0Mar 9, 1976--
010081910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03
Other1-$40$40Feb 9, 1976--
010091910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Other1-$40$40Feb 9, 1976--
010101910.309
OSHA citation code: 19100309 A 011017
Other1-$0$0Jan 12, 1976--
010111910.309
OSHA citation code: 19100309 A 004004
Other1-$0$0Jan 24, 1976--
020015A0001
General Duty Clause, Section 5(a)(1)
Serious1-$650$650Jan 12, 1976--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements4 citations · $900
1910.24Step Bolts and Manhole Steps3 citations · $80
1910.219Mechanical Power-Transmission Apparatus2 citations · $80

Other inspected employers in Kennett Square, PA

All employers in Kennett Square →