Inspection records
Mar 28, 1996#102943818Mar 28, 1996Planned (H) · Complete scope, Health#102943818$5,00019 viol.19 violations$5,000 in penalties
Inspection #102943818
Dates
- Opened
- Mar 28, 1996
- Closing Conference Date
- Jul 31, 1996
- Closed
- May 2, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 27
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 15 serious, 4 other-than-serious
- Initial Penalties
- $7,425
- Penalties on Record
- $5,000
- Site Address
- Route 113, Box 218, Kimberton, PA 19442
- Industry
- 325510 Paint and Coating Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (19 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 C01 | Serious | 1 | 5 | $1,100 | $750 | Sep 21, 1996 | - | - |
| 01004 | 1910.106 OSHA citation code: 19100106 E06 I | Serious | 1 | 27 | $1,100 | $750 | Aug 29, 1996 | - | - |
| 01005 | 1910.106 OSHA citation code: 19100106 E09 III | Serious | 1 | 27 | $825 | $750 | Aug 23, 1996 | - | - |
| 01006 | 1910.106 OSHA citation code: 19100106 E03 IV | Serious | 1 | 27 | $1,375 | $900 | Jan 1, 1997 | - | - |
| 01007A | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 D02 IA | Serious | 1 | 27 | $825 | $800 | Oct 1, 1996 | - | - |
| 01007B | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 D02 IB | Serious | 1 | 27 | $0 | $0 | Nov 1, 1996 | - | - |
| 01007C | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 F01 IIA | Serious | 1 | 27 | $0 | $0 | Apr 1, 1997 | - | - |
| 01007D | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 F01 IIIC | Serious | 1 | 27 | $0 | $0 | Apr 1, 1997 | - | - |
| 01007E | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 F03 | Serious | 1 | 27 | $0 | $0 | Apr 1, 1997 | - | - |
| 01007F | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 G01 II | Serious | 1 | 12 | $0 | $0 | Sep 21, 1996 | - | - |
| 01007G | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 G02 | Serious | 1 | 12 | $0 | $0 | May 1, 1997 | - | - |
| 01007H | 1910.119 Process Safety Management of Highly Hazardous Chemicals OSHA citation code: 19100119 L01 | Serious | 1 | 12 | $0 | $0 | Oct 1, 1996 | - | - |
| 01008 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 III | Serious | 1 | 27 | $825 | $250 | Aug 29, 1996 | - | - |
| 01009A | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 2 | 12 | $825 | $250 | Sep 5, 1996 | - | - |
| 01009B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 2 | 27 | $0 | $0 | Sep 5, 1996 | - | - |
| 02001 | 1910.22 OSHA citation code: 19100022 D01 | Other | 1 | 5 | $0 | $0 | Sep 21, 1996 | - | - |
| 02002 | 1910.37 OSHA citation code: 19100037 Q02 | Other | 1 | 27 | $0 | $0 | Sep 5, 1996 | - | - |
| 02003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 F02 I | Other | 1 | 12 | $0 | $0 | Aug 29, 1996 | - | - |
| 02004 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 K01 III | Other | 1 | 10 | $550 | $550 | Nov 1, 1996 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
Standards cited
Industry comparison
Chemical Manufacturing, 11,963 employers with OSHA inspections. Arithmetic from DOL records.