8
Feb 1990 to Oct 2000 · 5 safety, 3 health
Violations
35
across 8 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 21

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 5, 2000Follow-Up (F) · Partial scope, Safety#302282447$00 viol.

Inspection #302282447

Dates

Opened
Oct 5, 2000
Closing Conference Date
Oct 6, 2000
Closed
Oct 11, 2000

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2 North Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 31, 2000Planned (H) · Complete scope, Safety#301631503$013 viol.

Inspection #301631503

Dates

Opened
Jul 31, 2000
Closing Conference Date
Jul 31, 2000
Closed
Oct 11, 2000

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
13
Violation Types
4 serious, 9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2 North Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious16$0$0Aug 30, 2000--
010021910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D09 III
Serious13$0$0Oct 24, 2000--
010031910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 II
Serious13$0$0Oct 2, 2000--
010041926.601
Motor Vehicles
OSHA citation code: 19260601 B10
Serious31$0$0Dec 29, 2000--
020011910.37
OSHA citation code: 19100037 Q01
Other19$0$0Nov 15, 2000--
020021910.106
OSHA citation code: 19100106 G03 III
Other16$0$0Dec 29, 2000--

Showing the 6 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 4, 1997Follow-Up (F) · Partial scope, Safety#301627402$00 viol.

Inspection #301627402

Dates

Opened
Sep 4, 1997
Closing Conference Date
Sep 4, 1997
Closed
Sep 4, 1997

Inspection

Advance Notice
Yes
Owner Type
Local government
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 10, 1997Monitoring (D) · Partial scope, Safety#301626768$00 viol.

Inspection #301626768

Dates

Opened
Jul 10, 1997
Closing Conference Date
Jul 10, 1997
Closed
Jul 15, 1997

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jun 12, 1997Planned (H) · Complete scope, Safety#301626396$07 viol.

Inspection #301626396

Dates

Opened
Jun 12, 1997
Closing Conference Date
Jun 12, 1997
Closed
Sep 4, 1997

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 A09
Serious14$0$0Aug 22, 1997--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious14$0$0Aug 8, 1997--
010031910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious14$0$0Aug 1, 1997--
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other14$0$0Aug 22, 1997--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other14$0$0Aug 8, 1997--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other34$0$0Aug 8, 1997--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 23, 1990Follow-Up (F) · Partial scope, Health#104925375$00 viol.

Inspection #104925375

Dates

Opened
Jul 23, 1990
Closing Conference Date
Jul 23, 1990
Closed
Jul 23, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 13, 1990Follow-Up (F) · Partial scope, Health#104924790$00 viol.

Inspection #104924790

Dates

Opened
Jun 13, 1990
Closing Conference Date
Jun 13, 1990
Closed
Jun 13, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 6, 1990Planned (H) · Complete scope, Health#104880943$015 viol.

Inspection #104880943

Dates

Opened
Feb 6, 1990
Closing Conference Date
Feb 6, 1990
Closed
Jul 24, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
15
Violation Types
7 serious, 8 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
N Church St, Hunt, NY 14846
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 A05 IIB
Serious11$0$0Apr 24, 1990--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious13$0$0Apr 24, 1990--
010031910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious13$0$0Apr 24, 1990--
010041910.252
General requirements
OSHA citation code: 19100252 E02 III
Serious13$0$0Apr 24, 1990--
010051910.252
General requirements
OSHA citation code: 19100252 F02 IB
Serious13$0$0Apr 24, 1990--
010061910.1001
Asbestos
OSHA citation code: 19101001 D02 I
Serious13$0$0Apr 24, 1990--

Showing the 6 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties4 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 4 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01004#104924808Jun 20, 1990---
01005#104924808Jun 20, 1990---

Showing the 2 FTA rows present in the first 6 citations on this inspection. OSHA's record shows 4 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication8 citations · $0
1910.147The control of hazardous energy (lockout/tagout)3 citations · $0
1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0