Skip to content
SafetyRecord logoSafetyRecord
PORTEC INC RAILCAR DIVISION
$420
penalties
6
viol.
3
insp.

PORTEC INC RAILCAR DIVISION

HWY 29 EAST, WINDER, GA 30680

Inspections
3
Apr 1984 to Oct 1984 · 1 safety, 2 health
Violations
6
across 3 inspections
Penalties on record
$420
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 25, 1984Complaint (B) · Partial scope, Health#1176700$00 viol.

Inspection #1176700

Dates

Opened
Oct 25, 1984
Closing Conference Date
Jan 30, 1985
Closed
Jan 30, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
600
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hwy 29 East, Winder, GA 30680
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)80mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Cadmium Fume (as Cd)80mg/m³
Chromium, Metal and Insoluble Salts80 - 0.0036mg/m³
Cobalt, Metal, Dust and Fume (as Co)80mg/m³
Copper Fume (as Cu)80.0231 - 0.0961mg/m³
Iron Oxide Fume81.2614 - 4.9116mg/m³
Lead, Inorganic (as Pb)80mg/m³
Manganese Fume (as Mn)80.1648 - 0.5992mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)80 - 0.0216mg/m³
Nickel, Metal and Insoluble compounds (as Ni)80mg/m³
Particulates not otherwise regulated (Respirable Fraction)80mg/m³
Toluene70 - 2.5ppm
Vanadium fume (as V2O5)80mg/m³
Xylene70 - 10ppm
Zinc Oxide Fume81.3604 - 3.4344mg/m³
May 22, 1984Referral (C) · Complete scope, Health#1212588$00 viol.

Inspection #1212588

Dates

Opened
May 22, 1984
Closing Conference Date
Sep 7, 1984
Closed
Sep 26, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
353
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hwy 29 East, Winder, GA 30680
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling19 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Barium (Insoluble Compounds)20mg/m³
Barium, Soluble Compounds (as Ba)40mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Cadmium Fume (as Cd)90mg/m³
Chromium, Metal and Insoluble Salts90 - 0.0027mg/m³
Cobalt, Metal, Dust and Fume (as Co)90mg/m³
Copper Fume (as Cu)90 - 0.0255mg/m³
Fluorides (as F)20mg/m³
Hydrogen Fluoride (as F)20ppm
Iron Oxide Fume90.4652 - 5.5235mg/m³
Lead, Inorganic (as Pb)90mg/m³
Manganese Fume (as Mn)90.1258 - 1.2696mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90mg/m³
Particulates not otherwise regulated (Respirable Fraction)130mg/m³
Particulates not otherwise regulated (Total Dust)20mg/m³
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90 - 0.0153mg/m³
Apr 30, 1984Planned (H) · Complete scope, Safety#1212885$4206 viol.

Inspection #1212885

Dates

Opened
Apr 30, 1984
Closing Conference Date
May 2, 1984
Closed
Sep 26, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
323

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$420
Penalties on Record
$420
Site Address
Hwy 29 East, Winder, GA 30680
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.29
OSHA citation code: 19100029 A03 VI
Serious24$210$210May 16, 1984--
01001B1910.29
OSHA citation code: 19100029 A03 VI
Serious24$0$0May 16, 1984--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious11$210$210May 16, 1984--
020011910.304
Wiring design and protection
OSHA citation code: 19100304 A02
Other113$0$0May 16, 1984--
020021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other113$0$0May 16, 1984--
020031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other113$0$0May 16, 1984--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.292 citations · $210
1910.304Wiring design and protection2 citations · $0
1910.215Abrasive Wheel Machinery1 citation · $0

Chemical exposure sampling

Samples
268
Substances
21
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in WINDER, GA