POWER ELECTRIC CORP
2039 KENNEDY BLVD, Jersey City, NJ 07305
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 2, 2008#311564678Jan 2, 2008Programmed Related (I) · Complete scope, Safety#311564678$2,5006 viol.6 violations$2,500 in penalties
Inspection #311564678
Dates
- Opened
- Jan 2, 2008
- Closing Conference Date
- Jan 10, 2008
- Closed
- Jul 17, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 10
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 1 serious, 5 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $2,500
- Site Address
- 77 Hudson Street, Jersey City, NJ 07302
- Industry
- 238210 Electrical Contractors and Other Wiring Installation Contractors
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (5 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 I02 I | Other | 2 | 4 | $1,500 | $1,000 | Jun 26, 2008 | - | - |
| 01001B | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B02 | Other | 1 | 4 | $0 | $0 | Jul 11, 2008 | - | - |
| 01002A | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIE | Other | 1 | 5 | $1,500 | $1,000 | Jun 26, 2008 | - | - |
| 01002B | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 G02 III | Other | 1 | 3 | $0 | $0 | Jul 11, 2008 | - | - |
| 01002C | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 J01 II | Other | 2 | 4 | $0 | $0 | Jul 11, 2008 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 12, 2007#310696315Mar 12, 2007Unprogrammed Related (G) · Partial scope, Safety#310696315$00 viol.0 violations$0 in penalties
Inspection #310696315
Dates
- Opened
- Mar 12, 2007
- Closing Conference Date
- Mar 12, 2007
- Closed
- Mar 12, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 9
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Christopher Columbus Blvd. & Marin Blvd., Jersey City, NJ 07302
- Industry
- 238210 Electrical Contractors and Other Wiring Installation Contractors
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Mar 6, 2000#303302749Mar 6, 2000Unprogrammed Related (G) · Partial scope, Safety#303302749$2701 viol.1 violation$270 in penalties
Inspection #303302749
Dates
- Opened
- Mar 6, 2000
- Closing Conference Date
- Aug 23, 2000
- Closed
- Sep 27, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 100
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $675
- Penalties on Record
- $270
- Site Address
- 175 Warren Street, Jersey City, NJ 07303
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Other | 1 | 1 | $675 | $270 | Sep 1, 2000 | - | - |
May 9, 1997#300024064May 9, 1997Unprogrammed Related (G) · Complete scope, Safety#300024064$2533 viol.3 violations$253 in penalties
Inspection #300024064
Dates
- Opened
- May 9, 1997
- Closing Conference Date
- May 12, 1997
- Closed
- Jun 3, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $394
- Penalties on Record
- $253
- Site Address
- 155 Washington Street, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 B02 | Serious | 1 | - | $169 | $120 | May 16, 1997 | - | - |
| 01002A | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 A01 | Serious | 1 | - | $225 | $133 | May 29, 1997 | - | - |
| 01002B | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 | Serious | 1 | - | $0 | $0 | May 29, 1997 | - | - |
Feb 3, 1997#300022092Feb 3, 1997Unprogrammed Related (G) · Partial scope, Safety#300022092$01 viol.1 violation$0 in penalties
Inspection #300022092
Dates
- Opened
- Feb 3, 1997
- Closing Conference Date
- Feb 4, 1997
- Closed
- Feb 14, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 17
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 155 Washington Street, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIE | Other | 2 | 2 | $0 | $0 | Feb 10, 1997 | - | - |
Sep 23, 1993#107198814Sep 23, 1993Programmed Related (I) · Complete scope, Safety#107198814$00 viol.0 violations$0 in penalties
Inspection #107198814
Dates
- Opened
- Sep 23, 1993
- Closing Conference Date
- Sep 23, 1993
- Closed
- Oct 1, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 155 Washington Street, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Nov 24, 1992#108659939Nov 24, 1992Unprogrammed Related (G) · Complete scope, Safety#108659939$02 viol.2 violations$0 in penalties
Inspection #108659939
Dates
- Opened
- Nov 24, 1992
- Closing Conference Date
- Nov 25, 1992
- Closed
- Feb 4, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 155 Washington Street, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 A04 | Other | 1 | 2 | $0 | $0 | Jan 28, 1993 | - | - |
| 01002 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B01 | Other | 1 | 2 | $0 | $0 | Jan 27, 1993 | - | - |
Apr 30, 1987#100873041Apr 30, 1987Planned (H) · Complete scope, Safety#100873041$00 viol.0 violations$0 in penalties
Inspection #100873041
Dates
- Opened
- Apr 30, 1987
- Closing Conference Date
- Aug 17, 1987
- Closed
- Aug 17, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 10
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 145 12th Street, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 10, 1986#100175140Oct 10, 1986Planned (H) · Complete scope, Safety#100175140$8954 viol.4 violations$895 in penalties
Inspection #100175140
Dates
- Opened
- Oct 10, 1986
- Closing Conference Date
- Dec 18, 1986
- Closed
- Mar 31, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 39
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $1,280
- Penalties on Record
- $895
- Site Address
- 145 12th St, Jersey City, NJ 07302
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.28 Personal Protective Equipment OSHA citation code: 19260028 A | Serious | 1 | 1 | $480 | $335 | Mar 5, 1987 | - | - |
| 01002A | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Serious | 1 | 1 | $320 | $225 | Mar 5, 1987 | - | - |
| 01002B | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F07 IVC | Serious | 1 | 1 | $0 | $0 | Mar 19, 1987 | - | - |
| 01003 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 F01 | Serious | 1 | 1 | $480 | $335 | Mar 5, 1987 | - | - |
Nov 19, 1981#11101706Nov 19, 1981Planned (H) · Complete scope, Safety#11101706$01 viol.1 violation$0 in penalties
Inspection #11101706
Dates
- Opened
- Nov 19, 1981
- Closing Conference Date
- Nov 20, 1981
- Closed
- Dec 31, 1981
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Van Wagenen Apartments 11, Jersey City, NJ 07036
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.401 OSHA citation code: 19260401 J03 | Other | 1 | - | $0 | $0 | Nov 19, 1981 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
13 inspections, 1975 to 2008. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source