PRO ELECTRIC, INC.
3525 GARDNER, Kansas City, MO 64120
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 11, 2016#341318202Mar 11, 2016Planned (H) · Partial scope, Safety#341318202$00 viol.0 violations$0 in penalties
Inspection #341318202
Dates
- Opened
- Mar 11, 2016
- Closing Conference Date
- Mar 11, 2016
- Closed
- Jul 7, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 9401 N Oak Trafficway, Kansas City, MO 64154
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Aug 31, 2000#303208813Aug 31, 2000Programmed Related (I) · Complete scope, Safety#303208813$5001 viol.1 violation$500 in penalties
Inspection #303208813
Dates
- Opened
- Aug 31, 2000
- Closing Conference Date
- Aug 31, 2000
- Closed
- Sep 12, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $1,000
- Penalties on Record
- $500
- Site Address
- 1760 & 1770 North Corrington Ave, Kansas City, MO 64120
- Industry
- Not classified in OSHA's inspection record.
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Other | 1 | 3 | $1,000 | $500 | Sep 7, 2000 | - | - |
Jun 23, 1999#302247556Jun 23, 1999Referral (C) · Partial scope, Safety#302247556$00 viol.0 violations$0 in penalties
Inspection #302247556
Dates
- Opened
- Jun 23, 1999
- Closing Conference Date
- Jul 7, 1999
- Closed
- Jul 7, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 6
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1100 Main Street, 12th Floor, Kansas City, MO 64105
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Sep 27, 1989#101387132Sep 27, 1989Planned (H) · Complete scope, Safety#101387132$1801 viol.1 violation$180 in penalties
Inspection #101387132
Dates
- Opened
- Sep 27, 1989
- Closing Conference Date
- Sep 27, 1989
- Closed
- Oct 17, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 17
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $180
- Penalties on Record
- $180
- Site Address
- 9501 Hillcrest, Kansas City, MO 64137
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.701 Concrete and Masonry Construction - General Requirements OSHA citation code: 19260701 B | Serious | 1 | 1 | $180 | $180 | Oct 12, 1989 | - | - |
Jul 12, 1989#100895937Jul 12, 1989Planned (H) · Complete scope, Safety#100895937$05 viol.5 violations$0 in penalties
Inspection #100895937
Dates
- Opened
- Jul 12, 1989
- Closing Conference Date
- Jul 12, 1989
- Closed
- Sep 11, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Bldg. D - 25th & Mcgee, Kansas City, MO 64108
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Other | 1 | 2 | $0 | $0 | Aug 7, 1989 | - | - |
| 01002 | 1926.59 Hazard Communication OSHA citation code: 19260059 E01 | Other | 5 | 2 | $0 | $0 | Aug 7, 1989 | - | - |
| 01003 | 1926.59 Hazard Communication OSHA citation code: 19260059 F04 II | Other | 5 | 2 | $0 | $0 | Aug 7, 1989 | - | - |
| 01004 | 1926.59 Hazard Communication OSHA citation code: 19260059 G01 | Other | 5 | 2 | $0 | $0 | Aug 7, 1989 | - | - |
| 01005 | 1926.59 Hazard Communication OSHA citation code: 19260059 H | Other | 2 | 2 | $0 | $0 | Aug 7, 1989 | - | - |
Jul 5, 1989#101872661Jul 5, 1989Planned (H) · Complete scope, Safety#101872661$1802 viol.2 violations$180 in penalties
Inspection #101872661
Dates
- Opened
- Jul 5, 1989
- Closing Conference Date
- Jul 5, 1989
- Closed
- Jul 26, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $180
- Penalties on Record
- $180
- Site Address
- 700 East 12th Street, Kansas City, MO 64106
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 E10 | Serious | 1 | 1 | $180 | $180 | Jul 21, 1989 | - | - |
| 01001B | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 E04 | Serious | 1 | 1 | $0 | $0 | Jul 21, 1989 | - | - |
Dec 2, 1988#100898626Dec 2, 1988Planned (H) · Complete scope, Safety#100898626$01 viol.1 violation$0 in penalties
Inspection #100898626
Dates
- Opened
- Dec 2, 1988
- Closing Conference Date
- Dec 2, 1988
- Closed
- Dec 27, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3530 Chelsea, Kansas City, MO 64129
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 G01 I | Other | 1 | 1 | $0 | $0 | Dec 18, 1988 | - | - |
Apr 12, 1988#100899160Apr 12, 1988Planned (H) · Complete scope, Safety#100899160$01 viol.1 violation$0 in penalties
Inspection #100899160
Dates
- Opened
- Apr 12, 1988
- Closing Conference Date
- Apr 12, 1988
- Closed
- Jun 6, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 10525 Nw Ambassador, Kansas City, MO 64152
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 IIJ | Other | 1 | 1 | $0 | $0 | Apr 25, 1988 | - | - |
Mar 4, 1986#17590720Mar 4, 1986Planned (H) · Complete scope, Safety#17590720$03 viol.3 violations$0 in penalties
Inspection #17590720
Dates
- Opened
- Mar 4, 1986
- Closing Conference Date
- Mar 5, 1986
- Closed
- Mar 21, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 14th & Genessee, Kansas City, MO 64102
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 G | Other | 5 | 3 | $0 | $0 | Mar 17, 1986 | - | - |
| 01002 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 H03 I | Other | 3 | 3 | $0 | $0 | Mar 27, 1986 | - | - |
| 01003 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 E01 III | Other | 1 | 3 | $0 | $0 | Mar 18, 1986 | - | - |
Jul 11, 1985#100038975Jul 11, 1985Planned (H) · Complete scope, Safety#100038975$00 viol.0 violations$0 in penalties
Inspection #100038975
Dates
- Opened
- Jul 11, 1985
- Closing Conference Date
- Jul 11, 1985
- Closed
- Jul 11, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3901 Main, Kansas City, MO 64111
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
13 inspections, 1982 to 2016. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: nonresidential building construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 6.8%; NAICS 2362 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source