Skip to content
SafetyRecord logoSafetyRecord
PURSTAT ENGINEERED TECHNOLOGIES
$30,000
penalties
24
viol.
1
insp.

PURSTAT ENGINEERED TECHNOLOGIES

21 OLD FARM ROAD, LEWISTON, ME 04240NAICS 326112 Plastics Packaging Film and Sheet (including Laminated) Manufacturing

Inspections
1
Jul 2013 to Jul 2013 · 1 safety, 0 health
Violations
24
across 1 inspection
Penalties on record
$30,000
latest amounts in DOL records
By classification
Serious 22Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 9, 2013Planned (H) · Complete scope, Safety#339173627$30,00024 viol.

Inspection #339173627

Dates

Opened
Jul 9, 2013
Closing Conference Date
Jul 24, 2013
Final Order
Aug 8, 2013
Closed
Jul 26, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
29

Violations and Penalties

Total Violations
24
Violation Types
22 serious, 2 other-than-serious
Initial Penalties
$43,400
Penalties on Record
$30,000
Site Address
21 Old Farm Road, Lewiston, ME 04240
Industry
326112 Plastics Packaging Film and Sheet (including Laminated) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (24 of 24 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious15$2,100$1,449Aug 5, 2013-Aug 8, 2013
010021910.23
Ladders
OSHA citation code: 19100023 A08 II
Serious25$2,100$1,449Aug 7, 2013-Aug 8, 2013
010031910.23
Ladders
OSHA citation code: 19100023 C01
Serious56$3,500$2,415Sep 26, 2013-Aug 8, 2013
010041910.23
Ladders
OSHA citation code: 19100023 D01 III
Serious13$2,800$1,932Sep 26, 2013-Aug 8, 2013
01005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 II
Serious22$3,500$2,415Aug 1, 2013-Aug 8, 2013
01005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 II D
Serious22$0$0Aug 1, 2013-Aug 8, 2013
01005C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious12$0$0Aug 7, 2013-Aug 8, 2013
01005D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Serious11$0$0Aug 1, 2013-Aug 8, 2013
01006A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious11$2,800$1,932Aug 1, 2013-Aug 8, 2013
01006B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I A
Serious11$0$0Aug 1, 2013-Aug 8, 2013
010071910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 F03 I
Serious12$3,500$2,415Aug 1, 2013-Aug 8, 2013
010081910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$2,800$1,932Aug 1, 2013-Aug 8, 2013
01010A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious129$3,500$2,415Sep 30, 2013-Aug 8, 2013
01010B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Serious129$0$0Aug 28, 2013-Aug 8, 2013
010111910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$2,800$1,932Aug 14, 2013-Aug 8, 2013
010121910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious12$2,800$1,932Aug 5, 2013-Aug 8, 2013
010131910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious11$2,100$1,449Aug 14, 2013-Aug 8, 2013
010141910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01
Serious14$2,100$1,449-Aug 8, 2013
01015A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious12$2,100$1,449Aug 1, 2013-Aug 8, 2013
01015B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 C04
Serious12$0$0Aug 1, 2013-Aug 8, 2013
01016A1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious12$4,900$3,435Aug 30, 2013-Aug 8, 2013
01016B1910.335
Electrical - Safeguards
OSHA citation code: 19100335 A01 I
Serious12$0$0Aug 30, 2013-Aug 8, 2013
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other120$0$0Aug 28, 2013-Aug 8, 2013
020021910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 I
Other12$0$0Aug 5, 2013-Aug 8, 2013
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $6,762
1910.23Ladders3 citations · $5,796
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $1,449

Industry comparison

Violations per inspection
This employer24.0
Industry average2.8
Penalties per inspection
This employer$30,000
Industry average$3,080

Plastics and Rubber Products Manufacturing, 12,550 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: plastics packaging film and sheet (including laminated) manufacturing reported 2.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 14.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in LEWISTON, ME