Skip to content
SafetyRecord logoSafetyRecord
R P CONSTRUCTION COMPANY INC
$3,860
penalties
22
viol.
3
insp.

R P CONSTRUCTION COMPANY INC

723 ST. MARYS ST., Raleigh, NC 27605

Inspections
3
Jan 1991 to Feb 1998 · 3 safety, 0 health
Violations
22
across 3 inspections
Penalties on record
$3,860
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 1Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 13, 1998Unprogrammed Related (G) · Partial scope, Safety#302117593$1,5003 viol.

Inspection #302117593

Dates

Opened
Feb 13, 1998
Closing Conference Date
Mar 5, 1998
Closed
Jan 14, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$1,875
Penalties on Record
$1,500
Site Address
2815 Capitol Blvd, Raleigh, NC 27606
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Repeat12$1,500$1,300May 5, 1998--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H02 II
Serious12$375$200May 5, 1998--
030011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Other11$0$0Apr 22, 1998--
Sep 17, 1997Planned (H) · Complete scope, Safety#301960779$50012 viol.

Inspection #301960779

Dates

Opened
Sep 17, 1997
Closing Conference Date
Sep 30, 1997
Closed
Feb 20, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
12
Violation Types
8 serious, 4 other-than-serious
Initial Penalties
$500
Penalties on Record
$500
Site Address
Agricultural Communication Bldg, N.c. State Univ., Raleigh, NC 27607
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious25$350$350Jan 29, 1998--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01 I
Serious12$0$0Jan 29, 1998--
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 I
Serious12$0$0Jan 29, 1998--
01001D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 II
Serious12$0$0Jan 29, 1998--
01001E1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious12$0$0Jan 29, 1998--
01001F1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious12$0$0Jan 29, 1998--
01001G1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious12$0$0Jan 29, 1998--
010021926.1051
Stairways - General Requirements (Construction)
OSHA citation code: 19261051 A
Serious12$150$150Jan 29, 1998--
020011926.25
Housekeeping
OSHA citation code: 19260025 B
Other12$0$0Jan 29, 1998--
020021926.150
Fire Protection (Construction)
OSHA citation code: 19260150 A04
Other12$0$0Jan 29, 1998--
020031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 I
Other12$0$0Jan 29, 1998--
020041926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other12$0$0Jan 29, 1998--
Jan 15, 1991Planned (H) · Complete scope, Safety#15312481$1,8607 viol.

Inspection #15312481

Dates

Opened
Jan 15, 1991
Closing Conference Date
Jan 18, 1991
Contested
Apr 22, 1991
Final Order
Jun 30, 1992
Closed
Aug 19, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$2,740
Penalties on Record
$1,860
Site Address
723 St. Marys St., Raleigh, NC 27605
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious14$880$880Mar 3, 1991Apr 22, 1991Jun 30, 1992
010021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious14$880$0Mar 3, 1991Apr 22, 1991Jun 30, 1992
010031926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D01
Serious44$880$880Mar 3, 1991Apr 22, 1991Jun 30, 1992
020011926.152
OSHA citation code: 19260152 A01
Other14$0$0Mar 6, 1991Apr 22, 1991Jun 30, 1992
020021926.200
Accident Prevention Signs and Tags
OSHA citation code: 19260200 H01
Other34$100$100Mar 6, 1991Apr 22, 1991Jun 30, 1992
020031926.350
Gas Welding and Cutting
OSHA citation code: 19260350 A09
Other14$0$0Mar 6, 1991Apr 22, 1991Jun 30, 1992
020041926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 E01 V
Other14$0$0Mar 6, 1991Apr 22, 1991Jun 30, 1992
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements8 citations · $1,500
1926.500Scope, application, and definitions applicable to this subpart2 citations · $880
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $880

Other inspected employers in Raleigh, NC

All employers in Raleigh →