RALPH L. WADSWORTH CONSTRUCTION COMPANY, INC.
$5,410
penalties
57
viol.
2
insp.

RALPH L. WADSWORTH CONSTRUCTION COMPANY, INC.

BOISE-CHINDEN CONNECTOR, Boise, ID 83704

Inspections
2
Sep 1988 to May 1989 · 2 safety, 0 health
Violations
57
across 2 inspections
Penalties on record
$5,410
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 0Other 25

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 31, 1989Referral (C) · Complete scope, Safety#107027468$1,41013 viol.

Inspection #107027468

Dates

Opened
May 31, 1989
Closing Conference Date
Jun 2, 1989
Contested
Jul 14, 1989
Closed
Mar 23, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26
Related Activity
1 referral

Violations and Penalties

Total Violations
13
Violation Types
4 serious, 9 other-than-serious
Initial Penalties
$2,820
Penalties on Record
$1,410
Site Address
Boise-Chinden Connector, Boise, ID 83704
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Enforcement Outcome

Citation contest activity appears on Jul 14, 1989. Final orders are recorded through Nov 9, 1989. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious11$1,000$500Jun 18, 1989Jul 14, 1989Nov 9, 1989
010021926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 C04 IV
Serious11$240$120Jun 16, 1989-Nov 9, 1989
010031926.450
Scaffolding - Scope, Application, and Definitions
OSHA citation code: 19260450 A09
Serious110$480$240Jun 18, 1989-Nov 9, 1989
010041926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious110$1,000$500Jun 16, 1989-Nov 9, 1989
020011904.2
OSHA citation code: 19040002 A
Other110$100$50Jun 29, 1989-Nov 9, 1989
02002A1926.59
Hazard Communication
OSHA citation code: 19260059 E01
Other110$0$0Jul 17, 1989--
02002B1926.59
Hazard Communication
OSHA citation code: 19260059 G01
Other110$0$0Jul 17, 1989--
02002C1926.59
Hazard Communication
OSHA citation code: 19260059 H
Other110$0$0Jul 17, 1989--
020031926.350
Gas Welding and Cutting
OSHA citation code: 19260350 A09
Other21$0$0Jun 16, 1989--
020041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other11$0$0Jun 16, 1989--
020051926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 I
Other11$0$0Jun 16, 1989--
020061926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other11$0$0Jun 16, 1989--
020071926.450
Scaffolding - Scope, Application, and Definitions
OSHA citation code: 19260450 B12
Other11$0$0Jun 16, 1989--
Sep 14, 1988Planned (H) · Complete scope, Safety#17733130$4,00044 viol.

Inspection #17733130

Dates

Opened
Sep 14, 1988
Closing Conference Date
Sep 20, 1988
Contested
Dec 13, 1988
Final Order
Nov 13, 1989
Closed
Mar 23, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
44
Violation Types
28 serious, 16 other-than-serious
Initial Penalties
$10,390
Penalties on Record
$4,000
Site Address
Boise-Chinden Connector, Boise, ID 83704
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (25 of 44 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious160$810$270Dec 8, 1988Dec 13, 1988Nov 13, 1989
01001B1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious160$0$0Dec 1, 1988Dec 13, 1988Nov 13, 1989
010021926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious21$630$230Nov 25, 1988Dec 13, 1988Nov 13, 1989
010031926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious310$630$130Nov 25, 1988Dec 13, 1988Nov 13, 1989
010041926.300
General requirements
OSHA citation code: 19260300 B01
Serious11$360$100Nov 25, 1988Dec 13, 1988Nov 13, 1989
010051926.302
Power-Operated Hand Tools
OSHA citation code: 19260302 B01
Serious22$270$195Nov 25, 1988Dec 13, 1988Nov 13, 1989
010061926.304
Woodworking Tools
OSHA citation code: 19260304 F
Serious23$540$195Nov 25, 1988Dec 13, 1988Nov 13, 1989
010071926.304
Woodworking Tools
OSHA citation code: 19260304 F
Serious11$540$260Nov 25, 1988Dec 13, 1988Nov 13, 1989
010081926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious22$720$195Nov 25, 1988Dec 13, 1988Nov 13, 1989
010091926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIJ
Serious42$540$230Nov 25, 1988Dec 13, 1988Nov 13, 1989
01010A1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious71$630$195Nov 25, 1988Dec 13, 1988Nov 13, 1989
01010B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 V
Serious21$0$0Nov 25, 1988Dec 13, 1988Nov 13, 1989
01010C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 I
Serious11$0$0Nov 25, 1988Dec 13, 1988Nov 13, 1989
010111926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious42$540$165Nov 25, 1988Dec 13, 1988Nov 13, 1989
010121926.450
Scaffolding - Scope, Application, and Definitions
OSHA citation code: 19260450 A01
Serious22$450$165Nov 25, 1988Dec 13, 1988Nov 13, 1989
010131926.450
Scaffolding - Scope, Application, and Definitions
OSHA citation code: 19260450 A09
Serious21$450$130Nov 25, 1988Dec 13, 1988Nov 13, 1989
010141926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Serious18$360$130Nov 25, 1988Dec 13, 1988Nov 13, 1989
010151926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 B01
Serious210$360$165Nov 25, 1988Dec 13, 1988Nov 13, 1989
010161926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D01
Serious310$450$165Nov 28, 1988Dec 13, 1988Nov 13, 1989
010171926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D02
Serious26$450$195Nov 25, 1988Dec 13, 1988Nov 13, 1989
01018A1926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 F01
Serious410$230$230Nov 25, 1988Dec 13, 1988Nov 13, 1989
01018B1926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 F01 IV
Serious11$0$0Nov 25, 1988Dec 13, 1988Nov 13, 1989
01018C1926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 F01
Serious410$0$0Nov 25, 1988Dec 13, 1988Nov 13, 1989
01019A1926.550
OSHA citation code: 19260550 A01
Serious25$230$230Nov 25, 1988Dec 13, 1988Nov 13, 1989
01019B1926.550
OSHA citation code: 19260550 A05
Serious41$0$0Nov 25, 1988Dec 13, 1988Nov 13, 1989

Showing the 25 violations listed first by citation identifier. This inspection has 44 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)8 citations · $425
1926.500Scope, application, and definitions applicable to this subpart6 citations · $755
1926.450Scaffolding - Scope, Application, and Definitions5 citations · $535

Other inspected employers in Boise, ID