$1,460
penalties
16
viol.
5
insp.

REESE ENTERPRISES, INC./ASTRO PLASTICS

16350 ASHER AVE., ROSEMOUNT, MN 55068

Inspections
5
Aug 1989 to May 2002 · 5 safety, 0 health
Violations
16
across 5 inspections
Penalties on record
$1,460
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 21, 2002Planned (H) · Complete scope, Safety#305288110$4204 viol.

Inspection #305288110

Dates

Opened
May 21, 2002
Closing Conference Date
May 21, 2002
Closed
Jun 27, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$600
Penalties on Record
$420
Site Address
16350 Asher Ave., Rosemount, MN 55068
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B06 I
Serious11$500$350Jun 4, 2002--
02001A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B03
Other11$100$70Jun 4, 2002--
02001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other11$0$0Jun 4, 2002--
020021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Other71$0$0Jun 17, 2002--
Jan 6, 1994Follow-Up (F) · Partial scope, Safety#120394937$00 viol.

Inspection #120394937

Dates

Opened
Jan 6, 1994
Closing Conference Date
Jan 6, 1994
Closed
Jan 12, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
16350 Asher Ave., Rosemount, MN 55068
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Sep 1, 1993Planned (H) · Complete scope, Safety#120414651$4406 viol.

Inspection #120414651

Dates

Opened
Sep 1, 1993
Closing Conference Date
Sep 1, 1993
Closed
Dec 16, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$440
Penalties on Record
$440
Site Address
16350 Asher Ave., Rosemount, MN 55068
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$220$220Dec 31, 1993--
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H03
Serious11$220$220Oct 12, 1993--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other11$0$0Oct 18, 1993--
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Other11$0$0Dec 31, 1993--
020031910.217
Mechanical Power Presses
OSHA citation code: 19100217 B06 I
Other11$0$0Oct 12, 1993--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other14$0$0Oct 12, 1993--
Oct 12, 1989Follow-Up (F) · Partial scope, Safety#107736456$00 viol.

Inspection #107736456

Dates

Opened
Oct 12, 1989
Closing Conference Date
Oct 12, 1989
Closed
Oct 20, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
44

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
16350 Asher Ave., Rosemount, MN 55068
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 17, 1989Planned (H) · Complete scope, Safety#107748063$6006 viol.

Inspection #107748063

Dates

Opened
Aug 17, 1989
Closing Conference Date
Aug 17, 1989
Closed
Oct 12, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
44

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$600
Penalties on Record
$600
Site Address
16350 Asher Ave., Rosemount, MN 55068
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C 2 ID
Serious11$400$400Sep 18, 1989--
010021910.184
Slings
OSHA citation code: 19100184 D
Serious11$200$200Sep 25, 1989--
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G 2 III
Other11$0$0Sep 18, 1989--
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A 1
Other11$0$0Sep 18, 1989--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 G 1 I
Other11$0$0Sep 18, 1989--
020045206070001Other144$0$0Oct 10, 1989--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $750
1910.303Electrical - General Requirements2 citations · $0
1910.147Control of Hazardous Energy (Lockout/Tagout)2 citations · $0

Other inspected employers in ROSEMOUNT, MN

All employers in ROSEMOUNT →