ROYALTON TN WWTP
$0
penalties
4
viol.
8
insp.

ROYALTON TN WWTP

4244 BOLTON RD, Gasport, NY 14067

Inspections
8
Sep 1987 to Jun 2008 · 2 safety, 6 health
Violations
4
across 8 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 27, 2008Follow-Up (F) · Partial scope, Safety#306917006$00 viol.

Inspection #306917006

Dates

Opened
Jun 27, 2008
Closing Conference Date
Jun 27, 2008
Closed
Jun 27, 2008

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
19

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
221320 Sewage Treatment Facilities

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 5, 2008Planned (H) · Complete scope, Safety#306916099$01 viol.

Inspection #306916099

Dates

Opened
Feb 5, 2008
Closing Conference Date
Apr 15, 2008
Closed
Jun 27, 2008

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
19

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
221320 Sewage Treatment Facilities

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious16$0$0Sep 9, 2008--
Dec 2, 2002Follow-Up (F) · Partial scope, Health#302414768$00 viol.

Inspection #302414768

Dates

Opened
Dec 2, 2002
Closing Conference Date
Dec 2, 2002
Closed
Dec 2, 2002

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
221320 Sewage Treatment Facilities

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 20, 2002Monitoring (D) · Partial scope, Health#302414669$00 viol.

Inspection #302414669

Dates

Opened
Nov 20, 2002
Closing Conference Date
Nov 20, 2002
Closed
Nov 20, 2002

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
221320 Sewage Treatment Facilities

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 16, 2002Planned (H) · Complete scope, Health#302414487$02 viol.

Inspection #302414487

Dates

Opened
Oct 16, 2002
Closing Conference Date
Oct 16, 2002
Closed
Jan 6, 2003

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
221320 Sewage Treatment Facilities

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C05 IIC
Serious15$0$0Nov 27, 2002--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious15$0$0Nov 27, 2002--
Jan 27, 1998Follow-Up (F) · Partial scope, Health#301384822$00 viol.

Inspection #301384822

Dates

Opened
Jan 27, 1998
Closing Conference Date
Jan 27, 1998
Closed
Jan 27, 1998

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 7, 1997Planned (H) · Complete scope, Health#301383956$01 viol.

Inspection #301383956

Dates

Opened
Oct 7, 1997
Closing Conference Date
Oct 7, 1997
Closed
Jan 28, 1998

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D04 I
Serious15$0$0Feb 16, 1998--
Sep 24, 1987Planned (H) · Complete scope, Health#104727672$00 viol.

Inspection #104727672

Dates

Opened
Sep 24, 1987
Closing Conference Date
Sep 24, 1987
Closed
Nov 9, 1987

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4244 Bolton Rd, Gasport, NY 14067
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.146Permit-Required Confined Spaces2 citations · $0
1910.157Portable Fire Extinguishers1 citation · $0
1910.215Abrasive Wheel Machinery1 citation · $0

Industry comparison

BLS 2024 survey: sewage treatment facilities reported 1.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 40.1%; NAICS 22132 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Gasport, NY

All employers in Gasport →