Skip to content
SafetyRecord logoSafetyRecord
SATER ELECTRIC
$4,177
penalties
86
viol.
21
insp.

SATER ELECTRIC

(EDMUND BALL BLDG) 117 N MCKINLEY AVE, MUNCIE, IN 47304

Inspections
21
Dec 1982 to Jul 2007 · 19 safety, 2 health
Violations
86
across 21 inspections
Penalties on record
$4,177
latest amounts in DOL records
By classification
Serious 30Willful 0Repeat 4Other 52

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 17, 2007Planned (H) · Complete scope, Safety#311123343$00 viol.

Inspection #311123343

Dates

Opened
Jul 17, 2007
Closing Conference Date
Jul 18, 2007
Closed
Aug 8, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1601 E. 16th Street, Muncie, IN 47302
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 18, 2007Complaint (B) · Partial scope, Health#308198829$7979 viol.

Inspection #308198829

Dates

Opened
Jun 18, 2007
Closing Conference Date
Sep 13, 2007
Closed
Apr 14, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
88
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
8 serious, 1 other-than-serious
Initial Penalties
$1,225
Penalties on Record
$797
Site Address
801 North Walnut Street, Muncie, IN 47305
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.1101
Asbestos
OSHA citation code: 19261101 E01
Serious112$875$569Jan 10, 2008--
01001B1926.1101
Asbestos
OSHA citation code: 19261101 F01 I
Serious112$0$0Feb 1, 2008--
01001C1926.1101
Asbestos
OSHA citation code: 19261101 F02 I
Serious112$0$0Feb 1, 2008--
01001D1926.1101
Asbestos
OSHA citation code: 19261101 G09 I
Serious112$0$0Jan 3, 2008--
01001E1926.1101
Asbestos
OSHA citation code: 19261101 G09 IV
Serious112$0$0Jan 10, 2008--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 8, 2007Unprogrammed Related (G) · Partial scope, Health#310370002$01 viol.

Inspection #310370002

Dates

Opened
Jan 8, 2007
Closing Conference Date
Jan 25, 2007
Closed
May 1, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
13

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Muncie Central High School, Muncie, IN 47304
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Other13$0$0Apr 12, 2007--
Jan 22, 2004Planned (H) · Complete scope, Safety#307317776$01 viol.

Inspection #307317776

Dates

Opened
Jan 22, 2004
Closing Conference Date
Jan 23, 2004
Closed
Jun 3, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1809 West Riverside, Muncie, IN 47303
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
020011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 E01
Other115$0$0May 14, 2004--
May 29, 2003Planned (H) · Complete scope, Safety#306158692$1,1009 viol.

Inspection #306158692

Dates

Opened
May 29, 2003
Closing Conference Date
Jun 3, 2003
Closed
Aug 14, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
9
Violation Types
5 serious, 4 other-than-serious
Initial Penalties
$2,800
Penalties on Record
$1,100
Site Address
Music Instruction Building, Muncie, IN 47303
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.153
Liquefied Petroleum Gas (LP-Gas)
OSHA citation code: 19260153 H05
Serious120$875$500Jul 21, 2003--
01002B1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 D01
Serious120$0$100Jul 21, 2003--
010031926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious120$875$300Jul 21, 2003--
010041926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F07 IVC
Serious120$525$100Jul 21, 2003--
010051926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Serious120$525$100Jul 21, 2003--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 15, 1995Planned (H) · Complete scope, Safety#123985863$05 viol.

Inspection #123985863

Dates

Opened
May 15, 1995
Closing Conference Date
May 16, 1995
Closed
Jul 19, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(children's Museum&convention Ctr.)401 S.high St., Muncie, IN 47305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head protection
OSHA citation code: 19260100 C
Other11$0$0Jul 21, 1995--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other18$0$0Jul 21, 1995--
010031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B01
Other18$0$0Jul 21, 1995--
010041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other18$0$0Jul 21, 1995--
010051926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Other11$0$0Jul 21, 1995--
Apr 14, 1992Follow-Up (F) · Partial scope, Safety#108643362$00 viol.

Inspection #108643362

Dates

Opened
Apr 14, 1992
Closing Conference Date
Apr 14, 1992
Closed
May 1, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(youth Opportunity Center) 3316 Kilgore Avenue, Muncie, IN 47308
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 17, 1991Planned (H) · Complete scope, Safety#108576489$02 viol.

Inspection #108576489

Dates

Opened
Dec 17, 1991
Closing Conference Date
Dec 17, 1991
Closed
May 1, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(youth Opportunity Center) 3316 Kilgore Avenue, Muncie, IN 47308
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 EIV
Other11$0$0Mar 22, 1992--
010021926.150
Fire Protection (Construction)
OSHA citation code: 19260150 A01
Other11$0$0Mar 22, 1992--
Aug 12, 1991Complaint (B) · Partial scope, Safety#108625559$2401 viol.

Inspection #108625559

Dates

Opened
Aug 12, 1991
Closing Conference Date
Aug 12, 1991
Closed
Dec 23, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
4
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$240
Penalties on Record
$240
Site Address
(ball Arena) 1699 Bethel Avenue, Muncie, IN 47304
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious11$240$240Nov 16, 1991--
Apr 26, 1991Unprogrammed Related (G) · Complete scope, Safety#108625393$1,2008 viol.

Inspection #108625393

Dates

Opened
Apr 26, 1991
Closing Conference Date
May 31, 1991
Closed
Aug 6, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
30

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 3 repeat, 3 other-than-serious
Initial Penalties
$1,200
Penalties on Record
$1,200
Site Address
Ball State Arena Ball State University, Muncie, IN 47306
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 D10
Serious130$480$480Jul 21, 1991--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 E01 I
Serious13$240$240Jul 21, 1991--
020011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 A
Repeat11$160$160Jul 21, 1991--
020021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Repeat11$160$160Jul 21, 1991--
020031926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Repeat110$160$160Jul 21, 1991--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 10 of 21, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.150Fire Protection (Construction)10 citations · $0
1926.1101Asbestos8 citations · $569
1926.404Electrical - Wiring Design and Protection (Construction)8 citations · $880

Industry comparison

BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in MUNCIE, IN