Skip to content
SafetyRecord logoSafetyRecord
SME STEEL CONTRACTORS
$0
penalties
3
viol.
2
insp.
Inspections
2
Nov 1999 to Feb 2003 · 0 safety, 2 health
Violations
3
across 2 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 0Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 25, 2003Complaint (B) · Partial scope, Health#305516130$02 viol.

Inspection #305516130

Dates

Opened
Feb 25, 2003
Closing Conference Date
Feb 26, 2003
Closed
May 7, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
136
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
669 West Quinn Road, Building 28, Pocatello, ID 83201
Industry
811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)80mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Cadmium80mg/m³
Chromium, Metal and Insoluble Salts80mg/m³
Cobalt, Metal, Dust and Fume (as Co)80mg/m³
Copper Fume (as Cu)80 - 0.0200091mg/m³
Fluorides (as F)30.57 - 3.5mg/m³
Gravimetric DeterminationQC26.8391 - 6.8645mg/m³
Iron Oxide Fume84.5659204 - 16.6420898mg/m³
Lead, Inorganic (as Pb)80mg/m³
Manganese Fume (as Mn)80.6483062 - 4.4012885mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)80mg/m³
Nickel, Metal and Insoluble compounds (as Ni)80mg/m³
Particulates not otherwise regulated (Total Dust)26.8391 - 6.8645mg/m³
Sample WeightQC22.197 - 2.743mg
Vanadium fume (as V2O5)80mg/m³
Zinc Oxide Fume80 - 0.4434351mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other130$0$0May 14, 2003--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other1136$0$0May 29, 2003--
Nov 3, 1999Referral (C) · Partial scope, Health#302582929$01 viol.

Inspection #302582929

Dates

Opened
Nov 3, 1999
Closing Conference Date
Nov 3, 1999
Closed
Jan 21, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
180
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
669 West Quinn Road, Building 28, Pocatello, ID 83201
Industry
811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20.000033 - 0.000046mg/m³
Cadmium20 - 0.0002mg/m³
Chromium, Metal and Insoluble Salts20.0016 - 0.0021mg/m³
Cobalt, Metal, Dust and Fume (as Co)20 - 0.000335mg/m³
Copper Fume (as Cu)20.0173 - 0.0177mg/m³
Iron Oxide Fume23.0207 - 4.9445mg/m³
Lead, Inorganic (as Pb)20 - 0.0027mg/m³
Manganese Fume (as Mn)20.1906 - 0.456mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20 - 0.000611mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20.0019 - 0.0026mg/m³
Vanadium fume (as V2O5)20.0012 - 0.0014mg/m³
Zinc Oxide Fume20.0105 - 0.0146mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other11$0$0Dec 14, 1999--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection1 citation · $0
1910.178Powered Industrial Trucks1 citation · $0
1910.1200Hazard Communication1 citation · $0

Chemical exposure sampling

Samples
139
Substances
17
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer1.5
Industry average3.2
Penalties per inspection
This employer$0
Industry average$1,576

Repair and Maintenance, 33,743 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.5%; NAICS 8113 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in POCATELLO, ID

All employers in POCATELLO →