Skip to content
SafetyRecord logoSafetyRecord
SOUTH FLORIDA ALUMINUM, INC.
$10,053
penalties
22
viol.
5
insp.

SOUTH FLORIDA ALUMINUM, INC.

1230 WINGFIELD STREET, Lake Worth, FL 33460

Inspections
5
May 1989 to May 2012 · 3 safety, 2 health
Violations
22
across 5 inspections
Penalties on record
$10,053
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 31, 2012Referral (C) · Partial scope, Health#334543337$02 viol.

Inspection #334543337

Dates

Opened
May 31, 2012
Closing Conference Date
May 31, 2012
Final Order
Sep 13, 2012
Closed
Sep 12, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$3,200
Penalties on Record
$0
Site Address
1230 Wingfield St, Lake Worth, FL 33460
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
General requirements
OSHA citation code: 19100132 A
Other11$1,600$0Sep 10, 2012-Sep 13, 2012
010021910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Other113$1,600$0Sep 10, 2012-Sep 13, 2012
May 31, 2012Referral (C) · Partial scope, Health#334521358$1,6004 viol.

Inspection #334521358

Dates

Opened
May 31, 2012
Closing Conference Date
May 31, 2012
Final Order
Sep 28, 2012
Closed
Jan 28, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$3,200
Penalties on Record
$1,600
Site Address
1230 Wingfield St, Lake Worth, FL 33460
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious11$2,000$800Sep 28, 2012-Sep 28, 2012
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$1,200$800Sep 10, 2012-Sep 28, 2012
020011910.37
OSHA citation code: 19100037 A03
Other11$0$0-Sep 28, 2012
020021910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other11$0$0Oct 22, 2012-Sep 28, 2012
May 14, 2012Planned (H) · Complete scope, Safety#334405339$7,4408 viol.

Inspection #334405339

Dates

Opened
May 14, 2012
Closing Conference Date
May 14, 2012
Final Order
Jul 9, 2012
Closed
May 1, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$12,400
Penalties on Record
$7,440
Site Address
1230 Wingfield St, Lake Worth, FL 33460
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious52$2,000$1,400Jun 14, 2012-Jul 9, 2012
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious32$1,200$640Jun 14, 2012-Jul 9, 2012
01003A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious11$1,600$1,000Jun 14, 2012-Jul 9, 2012
01003B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$0$0Jun 14, 2012-Jul 9, 2012
010041910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious32$2,000$1,200Jun 14, 2012-Jul 9, 2012
010051910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious42$2,000$1,200Jun 14, 2012-Jul 9, 2012
010061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious21$2,000$1,000Jun 20, 2012-Jul 9, 2012
010071910.304
Wiring design and protection
OSHA citation code: 19100304 G05
Serious32$1,600$1,000Jun 14, 2012-Jul 9, 2012
Jun 9, 2003Planned (H) · Complete scope, Safety#306179680$1,0134 viol.

Inspection #306179680

Dates

Opened
Jun 9, 2003
Closing Conference Date
Jun 9, 2003
Closed
Jul 30, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$1,350
Penalties on Record
$1,013
Site Address
1230 Wingfield Street, Lake Worth, FL 33460
Industry
332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
OSHA citation code: 19100036 B04
Serious14$300$226Jul 28, 2003--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious42$375$281Jul 28, 2003--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious23$375$281Jul 28, 2003--
010041910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious14$300$225Jul 28, 2003--
May 25, 1989Unprogrammed Related (G) · Complete scope, Safety#18392555$04 viol.

Inspection #18392555

Dates

Opened
May 25, 1989
Closing Conference Date
Jun 6, 1989
Closed
Jul 14, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1230 Wingfield Street, Lake Worth, FL 33460
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.59
Hazard Communication
OSHA citation code: 19260059 E01
Other25$0$0Jul 19, 1989--
01001B1926.59
Hazard Communication
OSHA citation code: 19260059 G08
Other25$0$0Jul 19, 1989--
01001C1926.59
Hazard Communication
OSHA citation code: 19260059 H
Other25$0$0Jul 19, 1989--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other25$0$0Jun 18, 1989--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $2,962
1926.59Hazard Communication3 citations · $0
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $2,040

Other inspected employers in Lake Worth, FL

All employers in Lake Worth →