SPORT-CRAFT, INC.
500 HOUCK RD., PERRY, FL 32347
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 8, 1996#18005058May 8, 1996Monitoring (D) · Partial scope, Health#18005058$00 viol.0 violations$0 in penalties
Inspection #18005058
Dates
- Opened
- May 8, 1996
- Closing Conference Date
- May 8, 1996
- Closed
- May 17, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 79
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 500 Houck Rd., Perry, FL 32347
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Mar 19, 1996#18004812Mar 19, 1996Monitoring (D) · Partial scope, Health#18004812$00 viol.0 violations$0 in penalties
Inspection #18004812
Dates
- Opened
- Mar 19, 1996
- Closing Conference Date
- Mar 19, 1996
- Closed
- Apr 10, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 79
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 500 Houck Rd., Perry, FL 32347
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Nov 29, 1995#18003848Nov 29, 1995Monitoring (D) · Partial scope, Health#18003848$00 viol.0 violations$0 in penalties
Inspection #18003848
Dates
- Opened
- Nov 29, 1995
- Closing Conference Date
- Nov 29, 1995
- Closed
- Feb 8, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 79
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 500 Houck Rd., Perry, FL 32347
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Nov 30, 1994#110094026Nov 30, 1994Planned (H) · Complete scope, Health#110094026$3,00014 viol.14 violations$3,000 in penalties
Inspection #110094026
Dates
- Opened
- Nov 30, 1994
- Closing Conference Date
- Dec 2, 1994
- Closed
- Jul 25, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 79
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 13 serious, 1 other-than-serious
- Initial Penalties
- $3,000
- Penalties on Record
- $3,000
- Site Address
- 500 Houck Rd., Perry, FL 32347
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 2 | - | $500 | $500 | Jul 5, 1996 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 M01 | Serious | 2 | - | $0 | $0 | Jun 25, 1996 | - | - |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 II | Serious | 1 | 4 | $375 | $375 | Feb 19, 1995 | - | - |
| 01003A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C07 | Serious | 3 | - | $500 | $500 | Mar 22, 1995 | - | - |
| 01003B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 D05 | Serious | 3 | - | $0 | $0 | Mar 22, 1995 | - | - |
| 01003C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | - | $0 | $0 | Feb 10, 1995 | - | - |
| 01004A | 1910.108 Dip Tanks (Reserved) OSHA citation code: 19100108 C01 | Serious | 1 | 4 | $450 | $450 | May 6, 1995 | - | - |
| 01004B | 1910.108 Dip Tanks (Reserved) OSHA citation code: 19100108 C05 | Serious | 1 | 4 | $0 | $0 | May 6, 1995 | - | - |
| 01004C | 1910.108 Dip Tanks (Reserved) OSHA citation code: 19100108 F01 | Serious | 1 | 4 | $0 | $0 | Feb 7, 1995 | - | - |
| 01005 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 G02 | Serious | 2 | 4 | $425 | $425 | Feb 10, 1995 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 4, 1986#101782894Nov 4, 1986Planned (H) · Complete scope, Safety#101782894$21010 viol.10 violations$210 in penalties
Inspection #101782894
Dates
- Opened
- Nov 4, 1986
- Closing Conference Date
- Nov 5, 1986
- Closed
- Dec 9, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 205
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 1 serious, 9 other-than-serious
- Initial Penalties
- $210
- Penalties on Record
- $210
- Site Address
- 500 Houck Rd., Perry, FL 32347
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 D01 | Serious | 1 | 1 | $210 | $210 | Dec 3, 1986 | - | - |
| 02001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 I | Other | 3 | 8 | $0 | $0 | Dec 3, 1986 | - | - |
| 02002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B10 | Other | 3 | 1 | $0 | $0 | Dec 3, 1986 | - | - |
| 02003 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Other | 1 | 6 | $0 | $0 | Dec 3, 1986 | - | - |
| 02004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Other | 1 | 8 | $0 | $0 | Dec 3, 1986 | - | - |
| 02005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Other | 1 | 4 | $0 | $0 | Dec 3, 1986 | - | - |
| 02006 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A02 IVC | Other | 1 | 8 | $0 | $0 | Dec 3, 1986 | - | - |
| 02007 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 1 | 4 | $0 | $0 | Dec 3, 1986 | - | - |
| 02008 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Other | 1 | 6 | $0 | $0 | Dec 3, 1986 | - | - |
| 02009 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Other | 2 | 6 | $0 | $0 | Dec 3, 1986 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1986 to 1996. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.