Skip to content
SafetyRecord logoSafetyRecord
STANLEY FRONCZAK D/B/A CUSTOM PLATING & POLISHING
$10,170
penalties
78
viol.
2
insp.

STANLEY FRONCZAK D/B/A CUSTOM PLATING & POLISHING

3021 WEST LOCUST STREET, Milwaukee, WI 53210

Inspections
2
Jun 1988 to Sep 1990 · 2 safety, 0 health
Violations
78
across 2 inspections
Penalties on record
$10,170
latest amounts in DOL records
By classification
Serious 39Willful 5Repeat 11Other 23

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 19, 1990Follow-Up (F) · Complete scope, Safety#1932532$4,06038 viol.

Inspection #1932532

Dates

Opened
Sep 19, 1990
Closing Conference Date
Mar 1, 1991
Contested
Dec 28, 1990
Final Order
Aug 9, 1993
Closed
Mar 27, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19

Violations and Penalties

Total Violations
38
Violation Types
23 serious, 11 repeat, 4 other-than-serious
Initial Penalties
$17,040
Penalties on Record
$4,060
Site Address
3021 West Locust Street, Milwaukee, WI 53210
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)110 - 0.00005mg/m³
Cadmium Fume (as Cd)110 - 0.0008mg/m³
Copper Fume (as Cu)110 - 4.6973mg/m³
Hydrogen Chloride40 - 0.065ppm
Lead, Inorganic (as Pb)110 - 0.0799mg/m³
Nitric Acid40ppm
Nitrogen Dioxide60ppm
Silver, Metal and Soluble Compounds (as Ag)110 - 0.0045mg/m³
Sulfuric Acid30 - 0.061mg/m³
Tin, inorganic compounds (except oxides) (as Sn)80 - 0.0582mg/m³
Zinc Oxide Fume110 - 3.0099mg/m³

Violations

Violation list (25 of 38 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious111$2,500$170Dec 1, 1992Dec 28, 1990Aug 9, 1993
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious111$0$0Dec 1, 1992Dec 28, 1990Aug 9, 1993
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 J03
Serious12$350$100Jan 7, 1991Dec 28, 1990Aug 9, 1993
010031910.303
OSHA citation code: 19100303 G02 I
Serious11$640$170Dec 23, 1990Dec 28, 1990Aug 9, 1993
010041910.307
Hazardous (classified) locations
OSHA citation code: 19100307 B
Serious12$490$130Jan 7, 1991Dec 28, 1990Aug 9, 1993
010051910.1025
Lead
OSHA citation code: 19101025 D02
Serious111$420$110Mar 19, 1991Dec 28, 1990Aug 9, 1993
01006A1910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious111$350$95Jan 21, 1991Dec 28, 1990Aug 9, 1993
01006B1910.1025
Lead
OSHA citation code: 19101025 L02 I
Serious111$0$0Jan 7, 1991Dec 28, 1990Aug 9, 1993
020011910.22
OSHA citation code: 19100022 B01
Repeat16$560$150Dec 24, 1990Dec 28, 1990Aug 9, 1993
020021910.94
Ventilation
OSHA citation code: 19100094 D09 IV
Repeat11$700$190Dec 24, 1990Dec 28, 1990Aug 9, 1993
020031910.94
Ventilation
OSHA citation code: 19100094 D09 V
Repeat11$840$225Dec 24, 1990Dec 28, 1990Aug 9, 1993
020041910.132
General requirements
OSHA citation code: 19100132 A
Repeat12$560$150Dec 24, 1990Dec 28, 1990Aug 9, 1993
020051910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Repeat11$980$265Dec 24, 1990Dec 28, 1990Aug 9, 1993
020061910.141
Sanitation
OSHA citation code: 19100141 A03 I
Repeat110$280$75Dec 24, 1990Dec 28, 1990Aug 9, 1993
020071910.141
Sanitation
OSHA citation code: 19100141 D01
Repeat110$280$75Dec 24, 1990Dec 28, 1990Aug 9, 1993
020081910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Repeat15$280$75Dec 31, 1990Dec 28, 1990Aug 9, 1993
020091910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat31$980$260Jan 7, 1991Dec 28, 1990Aug 9, 1993
020101910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Repeat11$2,000$535Dec 24, 1990Dec 28, 1990Aug 9, 1993
030011904.2
OSHA citation code: 19040002 A
Other110$70$20Dec 31, 1990Dec 28, 1990Aug 9, 1993
030021904.4Other110$70$20Dec 31, 1990Dec 28, 1990Aug 9, 1993
030031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other12$140$35Jan 7, 1991Dec 28, 1990Aug 9, 1993
030041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Other12$140$35Jan 7, 1991Dec 28, 1990Aug 9, 1993
04001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Serious111$490$130Dec 1, 1992Mar 11, 1991Aug 9, 1993
04001B1910.1000
Air Contaminants
OSHA citation code: 19101000 F02 I
Serious111$0$0Dec 1, 1992Mar 11, 1991Aug 9, 1993
04002A1910.1025
Lead
OSHA citation code: 19101025 C01
Serious111$560$150Dec 1, 1992Mar 11, 1991Aug 9, 1993

Showing the 25 violations listed first by citation identifier. This inspection has 38 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 16, 1988FatalityAccident (A) · Complete scope, Safety#103468641$6,11040 viol.

Inspection #103468641

Dates

Opened
Jun 16, 1988
Closing Conference Date
Sep 14, 1988
Contested
Oct 3, 1988
Final Order
Nov 6, 1989
Closed
Mar 27, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 accident

Violations and Penalties

Total Violations
40
Violation Types
16 serious, 5 willful, 19 other-than-serious
Initial Penalties
$18,520
Penalties on Record
$6,110
Site Address
3021 West Locust Street, Milwaukee, WI 53210
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityJun 15, 1988

Electric shock - ground fault in electroplating tank

Injury: Electric ShockBody part: Body SystemSource: VibrationEvent: Shock

Chemical Exposure Sampling21 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)1614P / 2A0mg/m³
Beryllium and Beryllium Compounds (as Be)1413P / 1A0mg/m³
Cadmium Fume (as Cd)1614P / 2A0 - 0.0225mg/m³
Chromic Acid and Chromates (as CrO3)10mg/m³
Chromium, Metal and Insoluble Salts1614P / 2A0 - 0.0032mg/m³
Cobalt, Metal, Dust and Fume (as Co)1614P / 2A0mg/m³
Copper Fume (as Cu)1614P / 2A0 - 0.1378mg/m³
Cyanide (as Cn)10mg/m³
Hydrogen Cyanide10ppm
Iron Oxide Fume1614P / 2A0 - 11.5305mg/m³
Lead, Inorganic (as Pb)1614P / 2A0 - 0.0144mg/m³
Manganese Fume (as Mn)1614P / 2A0 - 0.0509mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)1614P / 2A0mg/m³
Nickel, Metal and Insoluble compounds (as Ni)1614P / 2A0 - 0.1564mg/m³
Nitric Oxide30.39 - 1.1ppm
Nitrogen Dioxide30 - 7ppm
Particulates not otherwise regulated (Respirable Fraction)1413P / 1A0mg/m³
Particulates not otherwise regulated (Total Dust)90mg/m³
Sulfuric Acid10.36mg/m³
Vanadium fume (as V2O5)1614P / 2A0 - 0.0039mg/m³
Zinc Oxide Fume1614P / 2A0 - 0.1041mg/m³

Violations

Violation list (25 of 40 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 D09 I
Serious15$250$125Oct 28, 1988Oct 3, 1988Nov 6, 1989
010021910.94
Ventilation
OSHA citation code: 19100094 D09 II
Serious14$150$75Sep 23, 1988Oct 3, 1988Nov 6, 1989
010031910.94
Ventilation
OSHA citation code: 19100094 D09 IV
Serious14$250$125Sep 23, 1988Oct 3, 1988Nov 6, 1989
010041910.94
Ventilation
OSHA citation code: 19100094 D09 V
Serious15$300$150Sep 23, 1988Oct 3, 1988Nov 6, 1989
010051910.94
Ventilation
OSHA citation code: 19100094 D09 VII
Serious14$200$100Oct 7, 1988Oct 3, 1988Nov 6, 1989
010061910.94
Ventilation
OSHA citation code: 19100094 D09 VIII
Serious13$250$125Oct 7, 1988Oct 3, 1988Nov 6, 1989
010071910.94
Ventilation
OSHA citation code: 19100094 D09 XI
Serious13$200$100Sep 23, 1988Oct 3, 1988Nov 6, 1989
010081910.94
Ventilation
OSHA citation code: 19100094 D10
Serious13$350$175Oct 28, 1988Oct 3, 1988Nov 6, 1989
010091910.132
General requirements
OSHA citation code: 19100132 A
Serious11$150$75Sep 17, 1988Oct 3, 1988Nov 6, 1989
010101910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious21$640$270Sep 23, 1988Oct 3, 1988Nov 6, 1989
01011A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious12$640$270Sep 17, 1988Oct 3, 1988Nov 6, 1989
01011B1910.1000
Air Contaminants
OSHA citation code: 19101000 B02
Serious12$0$0Mar 16, 1989Oct 3, 1988Nov 6, 1989
01011C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious12$0$0Mar 16, 1989Oct 3, 1988Nov 6, 1989
010121910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious41$0$150Oct 7, 1988Oct 3, 1988Nov 6, 1989
010131910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Serious33$640$270Sep 17, 1988Oct 3, 1988Nov 6, 1989
010141910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious14$200$100Sep 17, 1988Oct 3, 1988Nov 6, 1989
020011910.303
OSHA citation code: 19100303 B01
Willful15$9,000$2,250Sep 17, 1988Oct 3, 1988Nov 6, 1989
02002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Willful18$3,600$900Oct 7, 1988Oct 3, 1988Nov 6, 1989
02002B1910.1200
Hazard Communication
OSHA citation code: 19101200 F04 I
Willful18$0$0Oct 7, 1988Oct 3, 1988Nov 6, 1989
02002C1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Willful18$0$0Oct 28, 1988Oct 3, 1988Nov 6, 1989
02002D1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Willful18$0$0Oct 7, 1988Oct 3, 1988Nov 6, 1989
030011910.22
OSHA citation code: 19100022 B01
Other25$100$50Sep 17, 1988Oct 3, 1988Nov 6, 1989
030021910.94
Ventilation
OSHA citation code: 19100094 D02 I
Other18$100$50Oct 28, 1988Oct 3, 1988Nov 6, 1989
030031910.94
Ventilation
OSHA citation code: 19100094 D12 III
Other13$100$50Oct 7, 1988Oct 3, 1988Nov 6, 1989
030041910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other13$100$50Oct 28, 1988Oct 3, 1988Nov 6, 1989

Showing the 25 violations listed first by citation identifier. This inspection has 40 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties7 citations, $4,940 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 7 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01006#1932532Dec 17, 1990$1,320Dec 28, 1990Sep 23, 1992
02002A#1932532Dec 17, 1990$1,200Dec 28, 1990Sep 23, 1992
02002B#1932532Dec 17, 1990-Dec 28, 1990Sep 23, 1992
02002D#1932532Dec 17, 1990-Dec 28, 1990Sep 23, 1992
03002#1932532Dec 17, 1990$800Dec 28, 1990Sep 23, 1992
03004#1932532Dec 17, 1990$1,070Dec 28, 1990Sep 23, 1992

Showing the 6 FTA rows present in the first 25 citations on this inspection. OSHA's record shows 7 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead16 citations · $985
1910.94Ventilation12 citations · $1,490
1910.141Sanitation6 citations · $275

Chemical exposure sampling

Samples
333
Substances
25
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in Milwaukee, WI