Skip to content
SafetyRecord logoSafetyRecord
STERLING ENGINEERING AND FABRICATION, INC.
$14,837
penalties
5
viol.
5
insp.

STERLING ENGINEERING AND FABRICATION, INC.

101 JERRY DOWD DR., CARROLLTON, GA 30117NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
5
Aug 2015 to Jan 2025 · 2 safety, 3 health
Violations
5
across 5 inspections
Penalties on record
$14,837
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 23, 2025Complaint (B) · Partial scope, Health#347996076$2,9791 viol.

Inspection #347996076

Dates

Opened
Jan 23, 2025
Closing Conference Date
Jan 23, 2025
Final Order
Aug 1, 2025
Closed
Jan 20, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$4,965
Penalties on Record
$2,979
Site Address
101 Jerry Dowd Dr., Carrollton, GA 30117
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious11$4,965$2,979-Aug 1, 2025
Jan 23, 2025Complaint (B) · Partial scope, Safety#347995664$9,1052 viol.

Inspection #347995664

Dates

Opened
Jan 23, 2025
Closing Conference Date
Jan 23, 2025
Final Order
Aug 5, 2025
Closed
Sep 3, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$9,931
Penalties on Record
$9,105
Site Address
101 Jerry Dowd Dr., Carrollton, GA 30117
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1910.184
Slings
OSHA citation code: 19100184 I09 IV
Serious18$0$0Aug 6, 2025-Aug 5, 2025
010021910.252
General requirements
OSHA citation code: 19100252 B03
Serious18$9,931$9,105Aug 6, 2025-Aug 5, 2025
Jun 3, 2020Follow-Up (F) · Partial scope, Health#344775069$00 viol.

Inspection #344775069

Dates

Opened
Jun 3, 2020
Closing Conference Date
Jun 3, 2020
Closed
Sep 4, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 Jerry Dowd Dr., Carrollton, GA 30117
Industry
332312 Fabricated Structural Metal Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 3, 2019Planned (H) · Complete scope, Health#344375167$2,7532 viol.

Inspection #344375167

Dates

Opened
Oct 3, 2019
Closing Conference Date
Nov 7, 2019
Final Order
Apr 29, 2020
Closed
Sep 14, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$4,588
Penalties on Record
$2,753
Site Address
101 Jerry Dowd Dr., Carrollton, GA 30117
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.252
General requirements
OSHA citation code: 19100252 B02 III
Serious16$4,588$2,753-Apr 29, 2020
020011910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Other11$0$0-Apr 29, 2020
Aug 31, 2015Planned (H) · No Inspection scope, Safety#340887058$00 viol.

Inspection #340887058

Dates

Opened
Aug 31, 2015
Closing Conference Date
Aug 31, 2015
Closed
Sep 1, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 Jerry Dowd Dr., Carrollton, GA 30117
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection2 citations · $2,979
1910.252General requirements2 citations · $11,858
1910.184Slings1 citation · $0

Industry comparison

Violations per inspection
This employer1.0
Industry average3.3
Penalties per inspection
This employer$2,967
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,892 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CARROLLTON, GA

All employers in CARROLLTON →