Skip to content
SafetyRecord logoSafetyRecord
STERLING TIRE & RUBBER CO., INC.
$7,120
penalties
26
viol.
8
insp.

STERLING TIRE & RUBBER CO., INC.

COLBERT INDUSTRIAL PARK, Tuscumbia, AL 35674

Inspections
8
Apr 1979 to Mar 1991 · 8 safety, 0 health
Violations
26
across 8 inspections
Penalties on record
$7,120
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 20, 1991Planned (H) · Complete scope, Safety#106945561$5,25011 viol.

Inspection #106945561

Dates

Opened
Mar 20, 1991
Closing Conference Date
Mar 21, 1991
Closed
May 17, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$5,250
Penalties on Record
$5,250
Site Address
Colbert Industrial Park, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,225$1,225May 3, 1991--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious110$525$525Apr 16, 1991--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 I02
Serious16$875$875Apr 19, 1991--
01004A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious160$875$875May 3, 1991--
01004B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 D04 I
Serious1-$0$0Apr 16, 1991--
01005A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious12$875$875Apr 16, 1991--

Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 22, 1987Follow-Up (F) · Partial scope, Safety#101884815$00 viol.

Inspection #101884815

Dates

Opened
Jan 22, 1987
Closing Conference Date
Jan 23, 1987
Closed
Jan 27, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Colbert Industrial Park, Tuscumbia, AL 35660
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 12, 1986Follow-Up (F) · Partial scope, Safety#100323500$00 viol.

Inspection #100323500

Dates

Opened
Nov 12, 1986
Closing Conference Date
Nov 12, 1986
Closed
Dec 15, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Colbert Industrial Park, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 30, 1986Complaint (B) · Partial scope, Safety#101882595$4805 viol.

Inspection #101882595

Dates

Opened
Jul 30, 1986
Closing Conference Date
Jul 30, 1986
Closed
Mar 17, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$480
Penalties on Record
$480
Site Address
Colbert Industrial Park, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.303
OSHA citation code: 19100303 B01 I
Serious11$480$480Sep 26, 1986--
01001B1910.303
OSHA citation code: 19100303 E
Serious11$0$0Sep 26, 1986--
01001C1910.303
OSHA citation code: 19100303 G02 I
Serious11$0$0Sep 26, 1986--
01001D1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 IIIG
Serious11$0$0Sep 26, 1986--
01001E1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 II
Serious11$0$0Sep 26, 1986--

Failure to Abate Penalties1 citation, $160 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001C#100323500Dec 10, 1986$160--
Sep 5, 1985Planned (H) · Complete scope, Safety#2090660$9105 viol.

Inspection #2090660

Dates

Opened
Sep 5, 1985
Closing Conference Date
Sep 5, 1985
Closed
Feb 4, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$910
Penalties on Record
$910
Site Address
Colbert Industrial Park, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious12$210$210Sep 21, 1985--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious12$210$210Sep 21, 1985--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious15$280$280Sep 21, 1985--
010041910.244
Other Portable Tools and Equipment
OSHA citation code: 19100244 B
Serious11$210$210Oct 21, 1985--
020011904.2
OSHA citation code: 19040002 A
Other2-$0$0Sep 22, 1985--
Mar 9, 1982Planned (H) · Records Only scope, Safety#13272430$00 viol.

Inspection #13272430

Dates

Opened
Mar 9, 1982
Closing Conference Date
Mar 9, 1982
Closed
Mar 9, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Colbert Industrial Park, Tuscumbia, AL 33674
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 2, 1979Follow-Up (F) · Complete scope, Safety#13270319$00 viol.

Inspection #13270319

Dates

Opened
Aug 2, 1979
Closing Conference Date
Aug 2, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Colbert Industrial Park And H, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 19, 1979Planned (H) · Complete scope, Safety#13270087$4805 viol.

Inspection #13270087

Dates

Opened
Apr 19, 1979
Closing Conference Date
Apr 19, 1979
Closed
Aug 9, 1979

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$480
Penalties on Record
$480
Site Address
Colbert Industrial Park And Hi, Tuscumbia, AL 35674
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.216
Mills and Calenders in the Rubber and Plastics Industries
OSHA citation code: 19100216 C01
Serious1-$320$320Jun 30, 1979--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious2-$160$160Jun 30, 1979--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Other1-$0$0Jun 30, 1979--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Other1-$0$0Jun 30, 1979--
020031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other4-$0$0Jun 30, 1979--
Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Wiring methods, components, and equipment for general use4 citations · $875
1910.3034 citations · $480
1910.219Mechanical Power-Transmission Apparatus3 citations · $1,035

Other inspected employers in Tuscumbia, AL

All employers in Tuscumbia →