Skip to content
SafetyRecord logoSafetyRecord
SUPERIOR STEEL ERECTORS, INC.
$875
penalties
10
viol.
4
insp.

SUPERIOR STEEL ERECTORS, INC.

8249 WATERFORD ROAD, PASADENA, MD 21122

Inspections
4
Jan 1991 to Jan 2000 · 3 safety, 1 health
Violations
10
across 4 inspections
Penalties on record
$875
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 14, 2000Planned (H) · No Inspection scope, Health#302887104$00 viol.

Inspection #302887104

Dates

Opened
Jan 14, 2000
Closing Conference Date
Not recorded
Closed
Jan 20, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8249 Waterfaord Road, Pasadena, MD 21122
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 30, 1991Follow-Up (F) · Partial scope, Safety#104453253$00 viol.

Inspection #104453253

Dates

Opened
Jul 30, 1991
Closing Conference Date
Jul 30, 1991
Closed
Aug 7, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8249 Waterford Road, Pasadena, MD 21122
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 15, 1991Follow-Up (F) · Partial scope, Safety#104416334$00 viol.

Inspection #104416334

Dates

Opened
May 15, 1991
Closing Conference Date
May 15, 1991
Closed
Jun 26, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8249 Waterford Road, Pasadena, MD 21122
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 10, 1991Planned (H) · Complete scope, Safety#104450119$87510 viol.

Inspection #104450119

Dates

Opened
Jan 10, 1991
Closing Conference Date
Jan 10, 1991
Closed
Mar 18, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
10
Violation Types
7 serious, 3 other-than-serious
Initial Penalties
$1,980
Penalties on Record
$875
Site Address
8249 Waterfaord Road, Pasadena, MD 21122
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F 4
Serious11$330$100Feb 25, 1991--
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A E IIIF
Serious11$330$150Feb 25, 1991--
030011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B 2
Serious13$330$175Feb 25, 1991--
040011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J 1 I
Serious11$330$150Feb 25, 1991--
050011910.1200
Hazard Communication
OSHA citation code: 19101200 E 1
Serious11$330$150Feb 25, 1991--
06001A1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B 2 II
Serious11$330$150Feb 25, 1991--
06001B1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B 4 III
Serious11$0$0Feb 25, 1991--
070011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q 1
Other11$0$0Feb 24, 1991--
070021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A 4
Other11$0$0Feb 25, 1991--
07003912.3102
OSHA citation code: 09123102 A
Other125$0$0Feb 25, 1991--

Failure to Abate Penalties1 citation, $430 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
05001#104416334Jun 4, 1991$430--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $475
1910.253Oxygen-Fuel Gas Welding and Cutting2 citations · $150
1910.215Abrasive Wheel Machinery1 citation · $0

Other inspected employers in PASADENA, MD

All employers in PASADENA →