Skip to content
SafetyRecord logoSafetyRecord
TARMAC MID-ALANTIC INC.
$18,725
penalties
26
viol.
1
insp.

TARMAC MID-ALANTIC INC.

22963 CONCRETE PLAZA, STERLING, VA 20166

Inspections
1
Nov 1993 to Nov 1993 · 1 safety, 0 health
Violations
26
across 1 inspection
Penalties on record
$18,725
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 9, 1993Accident (A) · Complete scope, Safety#123680894$18,72526 viol.

Inspection #123680894

Dates

Opened
Nov 9, 1993
Closing Conference Date
Nov 23, 1993
Closed
Jun 22, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50
Related Activity
1 accident

Violations and Penalties

Total Violations
26
Violation Types
19 serious, 7 other-than-serious
Initial Penalties
$24,700
Penalties on Record
$18,725
Site Address
22963 Concrete Plaza, Sterling, VA 20166
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Violations

Violation list (26 of 26 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
Ladders
OSHA citation code: 19100023 A03
Serious22$1,625$1,625Apr 4, 1994--
01001B1910.23
Ladders
OSHA citation code: 19100023 A03 I
Serious12$0$0Mar 4, 1994--
010021910.23
Ladders
OSHA citation code: 19100023 C01
Serious54$1,625$1,625Apr 4, 1994--
010031910.23
Ladders
OSHA citation code: 19100023 C02
Serious23$1,625$1,625Apr 4, 1994--
010041910.26
Dockboards
OSHA citation code: 19100026 A01
Serious12$1,625$1,625Mar 4, 1994--
010051910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B01
Serious16$1,300$650Apr 4, 1994--
010061910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q06
Serious16$1,300$650Apr 4, 1994--
010071910.106
Flammable Liquids
OSHA citation code: 19100106 G03 III
Serious140$2,275$1,175Apr 4, 1994--
010081910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious44$1,625$1,625Apr 4, 1994--
010091910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious11$1,625$625Apr 4, 1994--
010101910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious24$1,625$1,625Apr 4, 1994--
010111910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious14$1,625$1,625Apr 4, 1994--
01012A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$1,625$1,625Jun 4, 1994--
01012B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$0$0Mar 4, 1994--
010131910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious14$1,625$825Mar 17, 1994--
010141910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A04
Serious24$1,625$825Jun 4, 1994--
01015A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$1,300$650Mar 4, 1994--
01015B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Mar 4, 1994--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other14$0$0Mar 4, 1994--
020021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIG
Other12$0$0Mar 4, 1994--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other13$0$0Mar 4, 1994--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious22$0$0Mar 4, 1994--
020051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other12$0$0Mar 17, 1994--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other12$0$0Mar 4, 1994--
020071910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other24$0$0Mar 10, 1994--
020081910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Other59$650$325Mar 10, 1994--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $0
1910.23Ladders4 citations · $4,875
1910.212General Requirements for All Machines (Machine Guarding)4 citations · $3,275

Other inspected employers in STERLING, VA

All employers in STERLING →