THE RIBEIRO CORP
5401 LONGLEY LANE, RENO, NV 89502
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 20, 2002#305755530Aug 20, 2002Complaint (B) · Partial scope, Health#305755530$00 viol.0 violations$0 in penalties
Inspection #305755530
Dates
- Opened
- Aug 20, 2002
- Closing Conference Date
- Aug 23, 2002
- Closed
- Aug 23, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6770 S. Mccarran Blvd. (quail Court), Reno, NV 89509
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Aug 14, 2001#304583214Aug 14, 2001Planned (H) · Complete scope, Safety#304583214$03 viol.3 violations$0 in penalties
Inspection #304583214
Dates
- Opened
- Aug 14, 2001
- Closing Conference Date
- Aug 14, 2001
- Closed
- Aug 20, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6770 S. Mccarran Blvd. (quail Court), Reno, NV 89509
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 H | Other | 1 | 1 | $0 | $0 | Aug 16, 2001 | - | - |
| 01002 | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 I | Other | 2 | 1 | $0 | $0 | Aug 15, 2001 | - | - |
| 01003 | 1926.200 Accident Prevention Signs and Tags OSHA citation code: 19260200 C01 | Other | 1 | 2 | $0 | $0 | Aug 15, 2001 | - | - |
Feb 13, 1998#301958278Feb 13, 1998Planned (H) · Complete scope, Safety#301958278$1,0006 viol.6 violations$1,000 in penalties
Inspection #301958278
Dates
- Opened
- Feb 13, 1998
- Closing Conference Date
- Feb 17, 1998
- Closed
- Apr 23, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 21
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 other-than-serious
- Initial Penalties
- $1,000
- Penalties on Record
- $1,000
- Site Address
- 501-525 Hammill Ln. (quail Village I), Reno, NV 89511
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 618055601 | Other | 1 | 21 | $1,000 | $1,000 | Apr 28, 1998 | - | - |
| 01001B | 618056501 | Other | 1 | 21 | $0 | $0 | Apr 28, 1998 | - | - |
| 01001C | 618056502 | Other | 1 | 21 | $0 | $0 | Apr 28, 1998 | - | - |
| 02001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 II | Other | 2 | 6 | $0 | $0 | Feb 17, 1998 | - | - |
| 02002 | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B01 II | Other | 1 | 1 | $0 | $0 | Feb 13, 1998 | - | - |
| 02003 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 III | Other | 1 | 2 | $0 | $0 | Feb 17, 1998 | - | - |
Nov 27, 1990#114610397Nov 27, 1990Follow-Up (F) · Partial scope, Safety#114610397$00 viol.0 violations$0 in penalties
Inspection #114610397
Dates
- Opened
- Nov 27, 1990
- Closing Conference Date
- Nov 27, 1990
- Closed
- Nov 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 5401 Longley Lane, Reno, NV 89502
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Sep 7, 1990#111175964Sep 7, 1990Planned (H) · Complete scope, Safety#111175964$3603 viol.3 violations$360 in penalties
Inspection #111175964
Dates
- Opened
- Sep 7, 1990
- Closing Conference Date
- Sep 7, 1990
- Closed
- Nov 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $1,440
- Penalties on Record
- $360
- Site Address
- 5401 Longley Lane, Reno, NV 89502
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.304 Woodworking Tools OSHA citation code: 19260304 F | Serious | 1 | 1 | $720 | $180 | Sep 7, 1990 | - | - |
| 01002A | 1926.304 Woodworking Tools OSHA citation code: 19260304 F | Serious | 1 | 4 | $720 | $180 | Oct 7, 1990 | - | - |
| 01002B | 1926.304 Woodworking Tools OSHA citation code: 19260304 F | Serious | 1 | 4 | $0 | $0 | Oct 7, 1990 | - | - |
Nov 4, 1987#104649058Nov 4, 1987Planned (H) · Complete scope, Safety#104649058$01 viol.1 violation$0 in penalties
Inspection #104649058
Dates
- Opened
- Nov 4, 1987
- Closing Conference Date
- Nov 4, 1987
- Closed
- Nov 5, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 5301 Longley Ln, Reno, NV 89523
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F06 | Other | 1 | 1 | $0 | $0 | Nov 4, 1987 | - | - |
Aug 11, 1987#104611397Aug 11, 1987Planned (H) · Complete scope, Safety#104611397$03 viol.3 violations$0 in penalties
Inspection #104611397
Dates
- Opened
- Aug 11, 1987
- Closing Conference Date
- Aug 11, 1987
- Closed
- Aug 17, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 5301 Longley Ln, Reno, NV 89523
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 A01 | Other | 1 | 2 | $0 | $0 | Aug 13, 1987 | - | - |
| 01002 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 E01 | Other | 1 | 2 | $0 | $0 | Aug 13, 1987 | - | - |
| 01003 | 1926.602 Material Handling Equipment OSHA citation code: 19260602 C01 VI | Other | 1 | 2 | $0 | $0 | Aug 13, 1987 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
7 inspections, 1987 to 2002. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.