Skip to content
SafetyRecord logoSafetyRecord
TIP TOP CONSTRUCTION
$6,263
penalties
7
viol.
6
insp.

TIP TOP CONSTRUCTION

231 MAIN STREET, BILLINGS, MT 59105

Inspections
6
Jun 2002 to Jul 2002 · 6 safety, 0 health
Violations
7
across 6 inspections
Penalties on record
$6,263
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 17, 2002Follow-Up (F) · Partial scope, Safety#304403991$00 viol.

Inspection #304403991

Dates

Opened
Jul 17, 2002
Closing Conference Date
Jul 17, 2002
Closed
Jul 17, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 17, 2002Planned (H) · Complete scope, Safety#304403983$6,0003 viol.

Inspection #304403983

Dates

Opened
Jul 17, 2002
Closing Conference Date
Jul 17, 2002
Closed
Jul 6, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$8,400
Penalties on Record
$6,000
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious22$2,800$2,000Jul 22, 2002--
010021926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious22$2,800$2,000Jul 22, 2002--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious33$2,800$2,000Jul 22, 2002--
Jul 1, 2002Complaint (B) · Complete scope, Safety#304403900$02 viol.

Inspection #304403900

Dates

Opened
Jul 1, 2002
Closing Conference Date
Jul 1, 2002
Closed
Jul 9, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Other22$0$0Jul 5, 2002--
010021926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Other22$0$0Jul 5, 2002--
Jul 1, 2002Follow-Up (F) · Partial scope, Safety#304403868$00 viol.

Inspection #304403868

Dates

Opened
Jul 1, 2002
Closing Conference Date
Jul 1, 2002
Closed
Jul 1, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 20, 2002Follow-Up (F) · Partial scope, Safety#304403777$00 viol.

Inspection #304403777

Dates

Opened
Jun 20, 2002
Closing Conference Date
Jun 20, 2002
Closed
Jun 20, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 19, 2002Planned (H) · Complete scope, Safety#304403751$2632 viol.

Inspection #304403751

Dates

Opened
Jun 19, 2002
Closing Conference Date
Jun 19, 2002
Closed
Oct 2, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$525
Penalties on Record
$263
Site Address
231 Main Street, Billings, MT 59105
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious11$525$263Jun 25, 2002--
01001B1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious12$0$0Jun 25, 2002--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.501Fall Protection - Duty to Have Fall Protection3 citations · $2,263
1926.100Head Protection (Construction)2 citations · $2,000
1926.102Eye and Face Protection (Construction)2 citations · $2,000

Other inspected employers in BILLINGS, MT

All employers in BILLINGS →