Skip to content
SafetyRecord logoSafetyRecord
TOTAL CONSTRUCTION ENTERPRISES, INC.
$8,100
penalties
16
viol.
1
insp.

TOTAL CONSTRUCTION ENTERPRISES, INC.

175 CENTRAL AVENUE, SPRING VALLEY, NY 10977

Inspections
1
Jul 1999 to Jul 1999 · 1 safety, 0 health
Violations
16
across 1 inspection
Penalties on record
$8,100
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 23, 1999Programmed Related (I) · Complete scope, Safety#302801253$8,10016 viol.

Inspection #302801253

Dates

Opened
Jul 23, 1999
Closing Conference Date
Jul 26, 1999
Closed
Jul 1, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
16
Violation Types
15 serious, 1 other-than-serious
Initial Penalties
$8,100
Penalties on Record
$8,100
Site Address
175 Central Avenue, Spring Valley, NY 10977
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious15$750$750Oct 10, 1999--
01001B1926.454
Scaffolding - Training
OSHA citation code: 19260454 A01
Serious15$0$0Oct 10, 1999--
01002A1926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious26$750$750Sep 22, 1999--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H01
Serious26$0$0Sep 22, 1999--
010031926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious15$750$750Sep 22, 1999--
01004A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious25$450$450Sep 30, 1999--
01004B1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 E
Serious15$0$0Sep 22, 1999--
010051926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious12$750$750Sep 22, 1999--
01006A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C03
Serious12$750$750Sep 22, 1999--
01006B1926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W01
Serious12$0$0Sep 22, 1999--
01007A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious14$450$450Sep 22, 1999--
01007B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E09 IV
Serious13$0$0Sep 22, 1999--
010081926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F14
Serious22$1,500$1,500Sep 22, 1999--
010091926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious25$1,500$1,500Sep 22, 1999--
010101926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W02
Serious25$450$450Sep 22, 1999--
020011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 II
Other15$0$0Sep 30, 1999--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements7 citations · $4,950
1926.452Additional Requirements for Specific Scaffold Types2 citations · $450
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $1,200