Skip to content
SafetyRecord logoSafetyRecord
TRANSWORLD SERVICES INC
$150
penalties
17
viol.
5
insp.

TRANSWORLD SERVICES INC

72 STONE PLACE, Melrose, MA 02176

Inspections
5
Oct 1979 to Apr 2009 · 3 safety, 2 health
Violations
17
across 5 inspections
Penalties on record
$150
latest amounts in DOL records
By classification
Serious 1Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 30, 2009Planned (H) · Partial scope, Health#313345001$00 viol.

Inspection #313345001

Dates

Opened
Apr 30, 2009
Closing Conference Date
Apr 30, 2009
Closed
Sep 11, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
72 Stone Place, Melrose, MA 02176
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 20, 1985Planned (H) · Complete scope, Safety#100441302$06 viol.

Inspection #100441302

Dates

Opened
Sep 20, 1985
Closing Conference Date
Sep 20, 1985
Closed
Mar 13, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
66

Violations and Penalties

Total Violations
6
Violation Types
6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
72 Stone Place, Melrose, MA 02176
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Other38$0$0Dec 30, 1985--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Other11$0$0Dec 30, 1985--
010031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Other22$0$0Dec 30, 1985--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 I01
Other12$0$0Dec 30, 1985--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other79$0$0Nov 21, 1985--
010061910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Other317$0$0Dec 30, 1985--
Mar 12, 1982Planned (H) · Records Only scope, Safety#10143303$00 viol.

Inspection #10143303

Dates

Opened
Mar 12, 1982
Closing Conference Date
Mar 12, 1982
Closed
Mar 12, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
75

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
72 Stone Place, Melrose, MA 02176
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 13, 1981Planned (H) · Complete scope, Health#10088946$05 viol.

Inspection #10088946

Dates

Opened
Nov 13, 1981
Closing Conference Date
Nov 13, 1981
Closed
Mar 26, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
72 Stone Pl, Melrose, MA 02176
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.38
OSHA citation code: 19100038 A01
Other1-$0$0Mar 8, 1982--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Other1-$0$0Jan 8, 1982--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other1-$0$0Jan 8, 1982--
010041910.252
General requirements
OSHA citation code: 19100252 A02 IIB
Other1-$0$0Jan 8, 1982--
010051910.303
OSHA citation code: 19100303 G02 I
Other2-$0$0Jan 8, 1982--
Oct 10, 1979Planned (H) · Complete scope, Safety#10141224$1506 viol.

Inspection #10141224

Dates

Opened
Oct 10, 1979
Closing Conference Date
Oct 10, 1979
Closed
Oct 28, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
69

Violations and Penalties

Total Violations
6
Violation Types
1 serious, 5 other-than-serious
Initial Penalties
$150
Penalties on Record
$150
Site Address
72 Stone Place, Melrose, MA 02176
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious17-$150$150Dec 10, 1979--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$0$0Oct 29, 1979--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other1-$0$0Oct 29, 1979--
020031910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other1-$0$0Nov 13, 1979--
020041910.309
OSHA citation code: 19100309 A 025045
Other1-$0$0Oct 29, 1979--
020051910.309
OSHA citation code: 19100309 A 025051
Other1-$0$0Oct 25, 1979--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)4 citations · $0
1910.3092 citations · $0
1910.213Woodworking Machinery Requirements2 citations · $0

Other inspected employers in Melrose, MA