Skip to content
SafetyRecord logoSafetyRecord
U S HOME CORPORATION
$60,000
penalties
14
viol.
1
insp.

U S HOME CORPORATION

4128 SLEEPY COURT WESTERN SKY PROJECT, Colorado Springs, CO 80925

Inspections
1
Dec 1993 to Dec 1993 · 1 safety, 0 health
Violations
14
across 1 inspection
Penalties on record
$60,000
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 4Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 3, 1993Complaint (B) · Partial scope, Safety#109538793$60,00014 viol.

Inspection #109538793

Dates

Opened
Dec 3, 1993
Closing Conference Date
Dec 3, 1993
Contested
Apr 15, 1994
Final Order
May 8, 1995
Closed
Jun 2, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4
Related Activity
1 complaint

Violations and Penalties

Total Violations
14
Violation Types
10 serious, 4 repeat
Initial Penalties
$110,575
Penalties on Record
$60,000
Site Address
4128 Sleepy Court Western Sky Project, Colorado Springs, CO 80925
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious310$2,125$2,450Feb 6, 1995Apr 15, 1994May 8, 1995
010031926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious210$2,975$1,040Feb 6, 1995Apr 15, 1994May 8, 1995
01005A1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Serious15$2,975$1,456Feb 6, 1995Apr 15, 1994May 8, 1995
01005B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Serious15$0$0Feb 6, 1995Apr 15, 1994May 8, 1995
01005C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious15$0$0Feb 6, 1995Apr 15, 1994May 8, 1995
010061926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G01 II
Serious12$5,000$2,450Feb 6, 1995Apr 15, 1994May 8, 1995
010081926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Serious23$5,000$2,450Feb 6, 1995Apr 15, 1994May 8, 1995
01011A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A03
Serious34$0$4,900Feb 6, 1995-May 8, 1995
01011B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A14
Serious34$0$0Feb 6, 1995-May 8, 1995
01011C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 M05
Serious34$0$0Feb 6, 1995-May 8, 1995
020011926.100
Head protection
OSHA citation code: 19260100 A
Repeat120$17,500$8,564Feb 6, 1995Apr 15, 1994May 8, 1995
020021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 U03
Repeat12$25,000$12,230Feb 6, 1995Apr 15, 1994May 8, 1995
020031926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D01
Repeat24$25,000$12,230Feb 6, 1995Apr 15, 1994May 8, 1995
020041926.1052
Stairways (Construction)
OSHA citation code: 19261052 C12
Repeat14$25,000$12,230Feb 6, 1995Apr 15, 1994May 8, 1995
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements5 citations · $19,580
1926.405Electrical - Wiring Methods (Construction)4 citations · $3,906
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $1,040

Other inspected employers in Colorado Springs, CO

All employers in Colorado Springs →